Fracture of Bioresorbable Vascular Scaffold After Side-Branch Balloon Dilation in Bifurcation Coronary Narrowings.

Manuel Pan1, Miguel Romero2, Soledad Ojeda2, Javier Suarez de Lezo2, Jose Segura2, Francisco Mazuelos2, Pedro Martin3, Alfonso Medina3, Jose Suarez de Lezo2.   

Abstract

The possibility of strut fractures after bioresorbable vascular scaffold (BVS) treatment is a new problem associated with the use of this novel technology. There is little in vivo information regarding the effects of lateral dilation on BVS. The present study aimed to evaluate the effects of lateral balloon dilation after bioresorbable vascular scaffold implantation in the treatment of bifurcation lesions. From January 2012 to February 2015, 49 patients with bifurcation lesions who had been treated with BVS required balloon dilation of the side branch (SB). Optical coherence tomographic studies were performed in each of these patients. In 3 patients (6%), the optical coherence tomographic results met the criteria for rupture. Prolonged inflation using a noncompliant balloon with a diameter within the expansion limits of the device resolved the complication in all patients. The clinical course was favorable in all patients, and there were no inhospital deaths or myocardial infarctions. At 14 ± 8 months of follow-up, 2 patients with integrity of the BVS presented target lesion revascularization (4%). Another patient (2%) suffered a probable stent thrombosis 11 months after the procedure (myocardial infarction and death at home). The patients with the BVS rupture at the index procedure had a favorable clinical outcome, and the 6-month computed tomographic scan revealed maintenance of the initial good results. In conclusion, minor BVS rupture after 2.5-mm lateral balloon dilation may occur but is infrequent (6%). Prolonged balloon inflation of the main vessel may partially restore the geometry of the BVS.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 26243578     DOI: 10.1016/j.amjcard.2015.07.015

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

1.  Long-term clinical results of biodegradable vascular scaffold ABSORB BVS™ using the PSP-technique in patients with acute coronary syndrome.

Authors:  Jarosław Hiczkiewicz; Sylwia Iwańczyk; Aleksander Araszkiewicz; Magdalena Łanocha; Dariusz Hiczkiewicz; Stefan Grajek; Maciej Lesiak
Journal:  Cardiol J       Date:  2019-02-14       Impact factor: 2.737

2.  Procedural findings and early healing response after implantation of a self-apposing bioresorbable scaffold in coronary bifurcation lesions.

Authors:  Emil Nielsen Holck; Camilla Fox-Maule; Trine Ørhøj Barkholt; Lars Jakobsen; Shengxian Tu; Michael Maeng; Jouke Dijkstra; Evald Høj Christiansen; Niels Ramsing Holm
Journal:  Int J Cardiovasc Imaging       Date:  2019-05-04       Impact factor: 2.357

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.