Katherine Small1, Chris Kelly2, Rachael Beldham-Collins2, Val Gebski3.
Abstract
INTRODUCTION: A comparative study was conducted comparing the difference between (1) conformal radiotherapy (CRT) to the whole breast with sequential boost excision cavity plans and (2) intensity-modulated radiation therapy (IMRT) to the whole breast with simultaneously integrated boost to the excision cavity. The computed tomography (CT) data sets of 25 breast cancer patients were used and the results analysed to determine if either planning method produced superior plans.Entities:
Keywords: Breast cancer; conformal radiotherapy; intensity-modulated radiotherapy (IMRT); lung dose; radiation therapy
Year: 2013 PMID: 26229603 PMCID: PMC4175795 DOI: 10.1002/jmrs.4
Source DB: PubMed Journal: J Med Radiat Sci ISSN: 2051-3895
Figure 1The whole-breast planning target volume (PTV) in green, the excision cavity PTV in orange, with the excision cavity clinical target volume contoured blue.
Different methods used when planning conformal radiation therapy plans. The total shows the number of patients requiring that specific planning technique
| Patient | 18-MV beam | 0.5-cm alternate-day bolus | Direct beam | Boost prescription | Electrons excision cavity | Photon excision cavity |
|---|---|---|---|---|---|---|
| 1 | X | |||||
| 2 | X | X | ||||
| 3 | X | X | ||||
| 4 | X | X | X | |||
| 5 | X | |||||
| 6 | X | |||||
| 7 | X | |||||
| 8 | X | X | ||||
| 9 | X | |||||
| 10 | X | X | ||||
| 11 | X | X | ||||
| 12 | X | X | ||||
| 13 | X | |||||
| 14 | X | X | ||||
| 15 | X | X | ||||
| 16 | X | X | X | X | ||
| 17 | X | |||||
| 18 | X | |||||
| 19 | X | |||||
| 20 | X | X | ||||
| 21 | X | X | ||||
| 22 | X | X | ||||
| 23 | X | |||||
| 24 | X | X | ||||
| 25 | X | X | ||||
| Total | 2 | 3 | 5 | 9 | 7 | 18 |
Figure 2Typical field arrangement for a conformally planned whole breast and sequential excision cavity photon boost.
Figure 3Typical field arrangement for an intensity-modulated radiotherapy planned whole breast and simultaneously integrated excision cavity photon boost.
Equations for the conformity indices used in this study. In this study, the reference isodose used was the 57 Gy (95% of 60 Gy) isodose line
| Conformity measure | Equation | Legend |
|---|---|---|
| Conformity index | TVRI/ | TVRI, target volume covered by the reference isodose |
| Conformation number | (TVRI/TV) ×(TVRI/ | TVRI, target volume covered by the reference isodose |
| TV, target volume | ||
The comparable maximum plan doses for conformal radiotherapy (CRT) and intensity-modulated radiation therapy (IMRT) with simultaneously integrated boost plans
| Maximum dose parameters | CRT | IMRT |
|---|---|---|
| Average maximum dose (cGy) | 6314.34 | 6371.52 |
| Range (cGy) | 6135.7–6501.3 | 6145.8–6616.8 |
| 95% Confidence interval | 6275.133, 6353.467 | 6145.8, 6616.8 |
| 0.08 | 0.08 |
The comparable lung doses of conformal radiotherapy (CRT) and intensity-modulated radiation therapy (IMRT) with simultaneously integrated boost plans. All lung dose measurements have a P-value ≤0.001
| Lung evaluation parameters | CRT | IMRT |
|---|---|---|
| Average lung mean dose (cGy) | 1206.64 | 1288.37 |
| V20 (%) | 20.03 | 21.73 |
| V30 (%) | 16.82 | 17.97 |
The average maximum heart doses for conformal radiotherapy (CRT) and intensity-modulated radiation therapy (IMRT) with simultaneously integrated boost plans
| Heart evaluation parameters | CRT | IMRT |
|---|---|---|
| Average maximum heart dose (cGy) | 5295.26 | 5209.87 |
| Range (cGy) | 4858.3–5743.8 | 4895.17–5862.8 |
| 0.08 | 0.08 |
The average conformity indices, confidence intervals (CI), and P-values for the conformal and intensity-modulated radiation therapy (IMRT) plans
| Plan evaluation indices | Conformal radiotherapy | IMRT |
|---|---|---|
| Average conformity index | 0.5844 | 0.7527 |
| 95% CI | 0.557, 0.6107 | 0.726, 0.779 |
| ≤0.001 | ≤0.001 | |
| Average conformation number | 0.5665 | 0.7386 |
| 95% CI | 0.543, 0.589 | 0.7127, 0.765 |
| ≤0.001 | ≤0.001 |
Figure 4Comparison of conformal radiotherapy and intensity-modulated radiation therapy plan conformity indices for the excision cavity planning target volume.