Literature DB >> 2622234

Laboratory-scale finned-rotor impeller for dialysis.

M A el-Kalay, A E Nasser.   

Abstract

Dialysis of blood and other fluids may be accomplished using semi-permeable membranes. Most commonly used are the commercially available hollow-fibre dialysers, which have large priming volumes, an important consideration especially when laboratory techniques are being developed. With dialysis tubing (DT), however, priming volumes are readily controlled. To ensure adequate mass transfer, mixing of both dialysate and DT content is necessary. An impeller-based dialyser which consists of two open-boxed finned rotors facilitates both dialysate and DT content mixing. The operation of this device relies on the difference in hydrodynamic forces acting on opposite ends of the rotors, causing rotation in the vertical plane. This laboratory device was assessed via mass-transfer trials in which saline and washed-packed erythrocytes were dialysed against hypo- and hypertonic dialysate, allowing estimation of the DT's overall mass-transfer coefficient. Experimental correlation between the angular speeds of the impeller's rotation in the horizontal plane omega H and finned rotors' rotation in the vertical plane omega V were also established. Results indicate that the osmolality of the DT's content follows an exponential decay, and that omega V is strongly dependent on both omega H and the submergence depth of the impeller.

Entities:  

Mesh:

Year:  1989        PMID: 2622234     DOI: 10.1007/bf02441472

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  Design and fabrication of laboratory-scale membrane separation units.

Authors:  M A el-Kalay; T Gilchrist
Journal:  Med Biol Eng Comput       Date:  1987-11       Impact factor: 2.602

2.  Determination of the diffusive and hydraulic permeabilities of capillary hollow fibre membranes: theoretical mathematical models.

Authors:  M A el-Kalay; T Gilchrist
Journal:  Med Biol Eng Comput       Date:  1988-05       Impact factor: 2.602

3.  Membrane transport in resealed haemoglobin-containing human erythrocyte 'ghosts' prepared by a dialysis procedure.

Authors:  U Sprandel; A R Hubbard; R A Chalmers
Journal:  Biochem Biophys Res Commun       Date:  1979-11-14       Impact factor: 3.575

4.  An erythrocyte encapsulator dialyzer used in preparing large quantities of erythrocyte ghosts and encapsulation of a pesticide in erythrocyte ghosts.

Authors:  J R DeLoach; R L Harris; G M Ihler
Journal:  Anal Biochem       Date:  1980-02       Impact factor: 3.365

5.  Continuous-flow hollow-fiber dialysis system for preparation of bovine carrier erythrocytes.

Authors:  J R DeLoach
Journal:  Am J Vet Res       Date:  1985-05       Impact factor: 1.156

6.  In vitro studies on resealed erythrocyte ghosts as protein carriers.

Authors:  U Sprandel; A R Hubbard; R A Chalmers
Journal:  Res Exp Med (Berl)       Date:  1979-07-20

7.  Asparaginase entrapped in red blood cells: action and survival.

Authors:  S J Updike; R T Wakamiya; E N Lightfoot
Journal:  Science       Date:  1976-08-20       Impact factor: 47.728

8.  Pharmacokinetics of tetracycline encapsulated in bovine carrier erythrocytes.

Authors:  J R DeLoach; G G Wagner
Journal:  Am J Vet Res       Date:  1984-04       Impact factor: 1.156

9.  Activity of immunoglobulin G-coated red cell ghosts containing pentamidine against macrophage-contained Leishmania in vitro.

Authors:  J D Berman; M Aikawa
Journal:  Am J Trop Med Hyg       Date:  1984-11       Impact factor: 2.345

10.  Preparation of resealed carrier erythrocytes and in vivo survival in dogs.

Authors:  J R DeLoach; C Barton; K Culler
Journal:  Am J Vet Res       Date:  1981-04       Impact factor: 1.156

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.