Literature DB >> 26220129

[New aspects from legislation, guidelines and safety standards for MRI].

M Mühlenweg1, G Schaefers, S Trattnig.   

Abstract

Many aspects of magnetic resonance (MR) operation are not directly regulated by law but in standards, guidelines and the operating instructions of the MR scanner. The mandatory contents of the operating instructions are regulated in a central standard of the International Electrotechnical Commission (IEC) 60601-2-33. In this standard, the application of static magnetic fields in MRI up to 8 Tesla (T) in the clinical routine (first level controlled mode) has recently been approved. Furthermore, the equally necessary CE certification of ultra-high field scanners (7-8 T) in Europe is expected for future devices. The existing installations will not be automatically certified but will retain their experimental status. The current extension of IEC 60601-2-33 introduces a new add-on option, the so-called fixed parameter option (FPO). This option might also be switched on in addition to the established operating modes and defines a fixed device constellation and certain parameters of the energy output of MR scanners designed to simplify the testing of patients with implants in the future.The employment of pregnant workers in an MRI environment is still not generally regulated in Europe. In parts of Germany and Austria pregnant and lactating employees were prohibited from working in the MR control zone (0.5 mT) in 2014. This is based on the mostly unresolved question of the applicability of limits for employees (exposure of extremities to static magnetic fields up to 8 T allowed) or the thresholds for the general population (maximum 400 mT). According to the European Society of Urogenital Radiology (ESUR), the discarding of breast milk after i.v. administration of gadolinium-based contrast agents in the case of a breastfeeding woman is only recommended when using contrast agents in the nephrogenic systemic fibrosis (NSF) high-risk category.

Entities:  

Mesh:

Year:  2015        PMID: 26220129     DOI: 10.1007/s00117-015-2859-z

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  20 in total

Review 1.  Occupational exposure in MRI.

Authors:  D W McRobbie
Journal:  Br J Radiol       Date:  2012-04       Impact factor: 3.039

Review 2.  A review of the current use of magnetic resonance imaging in pregnancy and safety implications for the fetus.

Authors:  J P De Wilde; A W Rivers; D L Price
Journal:  Prog Biophys Mol Biol       Date:  2005 Feb-Apr       Impact factor: 3.667

3.  ACR guidance document for safe MR practices: 2007.

Authors:  Emanuel Kanal; A James Barkovich; Charlotte Bell; James P Borgstede; William G Bradley; Jerry W Froelich; Tobias Gilk; J Rod Gimbel; John Gosbee; Ellisa Kuhni-Kaminski; James W Lester; John Nyenhuis; Yoav Parag; Daniel J Schaefer; Elizabeth A Sebek-Scoumis; Jeffrey Weinreb; Loren A Zaremba; Pamela Wilcox; Leonard Lucey; Nancy Sass
Journal:  AJR Am J Roentgenol       Date:  2007-06       Impact factor: 3.959

4.  ACR guidance document on MR safe practices: 2013.

Authors:  Emanuel Kanal; A James Barkovich; Charlotte Bell; James P Borgstede; William G Bradley; Jerry W Froelich; J Rod Gimbel; John W Gosbee; Ellisa Kuhni-Kaminski; Paul A Larson; James W Lester; John Nyenhuis; Daniel Joe Schaefer; Elizabeth A Sebek; Jeffrey Weinreb; Bruce L Wilkoff; Terry O Woods; Leonard Lucey; Dina Hernandez
Journal:  J Magn Reson Imaging       Date:  2013-01-23       Impact factor: 4.813

5.  Central nervous system and facial defects associated with maternal hyperthermia at four to 14 weeks' gestation.

Authors:  H Pleet; J M Graham; D W Smith
Journal:  Pediatrics       Date:  1981-06       Impact factor: 7.124

6.  Hyperthermia as a possible teratogenic agent.

Authors:  D W Smith; S K Clarren; M A Harvey
Journal:  J Pediatr       Date:  1978-06       Impact factor: 4.406

7.  Amendment to the ICNIRP "Statement on medical magnetic resonance (MR) procedures: protection of patients".

Authors: 
Journal:  Health Phys       Date:  2009-09       Impact factor: 1.316

8.  Guidelines for limiting exposure to electric fields induced by movement of the human body in a static magnetic field and by time-varying magnetic fields below 1 Hz.

Authors: 
Journal:  Health Phys       Date:  2014-03       Impact factor: 1.316

9.  Guidelines on limits of exposure to static magnetic fields. International Commission on Non-Ionizing Radiation Protection.

Authors: 
Journal:  Health Phys       Date:  1994-01       Impact factor: 1.316

10.  Specific absorption rate in neonates undergoing magnetic resonance procedures at 1.5 T and 3 T.

Authors:  Shaihan J Malik; Arian Beqiri; Anthony N Price; Jose Nuno Teixeira; Jeffrey W Hand; Joseph V Hajnal
Journal:  NMR Biomed       Date:  2015-01-16       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.