Literature DB >> 26219682

Direct identification of major Gram-negative pathogens in respiratory specimens by respiFISH® HAP Gram (-) Panel, a beacon-based FISH methodology.

R Koncan1, M Parisato2, C Sakarikou3, G Stringari4, C Fontana3,5, V Favuzzi6, M Ligozzi6, G Lo Cascio2.   

Abstract

Rapid detection of microorganisms in respiratory specimens is of paramount importance to drive the proper antibiotic regimen to prevent complications and transmission of infections. In the present study, the respiFISH® HAP Gram (-) Panel (miacom diagnostics GmbH, Duesseldorf, Germany) for the etiological diagnosis of hospital-acquired pneumonia was compared with the traditional culture method for the detection of major Gram-negative pathogens in respiratory specimens. respiFISH® combined the classical fluorescence in situ hybridization (FISH) technology with fluorescence-labeled DNA molecular beacons as probes. From September 2011 to January 2012, 165 samples were analyzed: the sensitivity and specificity were 94.39 and 87.93%, respectively. Only six pathogens (3.6%) were not identified with respiFISH®, while seven specimens (3%) provided false-positive results. This beacon-based identification shortens the time to result by at least one work day, providing species-level identification within half an hour. Considering the high sensitivity and specificity and the significant time saving, the introduction of bbFISH® assays could effectively complement traditional systems in microbiology laboratories.

Entities:  

Mesh:

Year:  2015        PMID: 26219682     DOI: 10.1007/s10096-015-2458-y

Source DB:  PubMed          Journal:  Eur J Clin Microbiol Infect Dis        ISSN: 0934-9723            Impact factor:   3.267


  18 in total

1.  Rapid diagnosis of bacterial meningitis by real-time PCR and fluorescence in situ hybridization.

Authors:  Sven Poppert; Andreas Essig; Barbara Stoehr; Adelinde Steingruber; Beate Wirths; Stefan Juretschko; Udo Reischl; Nele Wellinghausen
Journal:  J Clin Microbiol       Date:  2005-07       Impact factor: 5.948

2.  Rapid diagnosis of intrapartum group B streptococcal carriage by fluorescent in situ hybridisation.

Authors:  K A Goddard; R Townsend; E Ridgway
Journal:  J Clin Pathol       Date:  2007-07       Impact factor: 3.411

Review 3.  Laboratory turnaround time.

Authors:  P Valenstein
Journal:  Am J Clin Pathol       Date:  1996-06       Impact factor: 2.493

4.  Evaluation of stat and routine turnaround times as a component of laboratory quality.

Authors:  L H Hilborne; R K Oye; J E McArdle; J A Repinski; D O Rodgerson
Journal:  Am J Clin Pathol       Date:  1989-03       Impact factor: 2.493

5.  Sensitivity, specificity, and reproducibility of four measures of laboratory turnaround time.

Authors:  P N Valenstein; K Emancipator
Journal:  Am J Clin Pathol       Date:  1989-04       Impact factor: 2.493

6.  Fluorescent-oligonucleotide probing of whole cells for determinative, phylogenetic, and environmental studies in microbiology.

Authors:  R I Amann; L Krumholz; D A Stahl
Journal:  J Bacteriol       Date:  1990-02       Impact factor: 3.490

Review 7.  Ventilator-associated pneumonia.

Authors:  Jean Chastre; Jean-Yves Fagon
Journal:  Am J Respir Crit Care Med       Date:  2002-04-01       Impact factor: 21.405

Review 8.  Hospital-acquired pneumonia and ventilator-associated pneumonia: recent advances in epidemiology and management.

Authors:  François Barbier; Antoine Andremont; Michel Wolff; Lila Bouadma
Journal:  Curr Opin Pulm Med       Date:  2013-05       Impact factor: 3.155

9.  Diagnostic techniques in bloodstream infections: where are we going?

Authors:  Stefania Stefani
Journal:  Int J Antimicrob Agents       Date:  2009       Impact factor: 5.283

10.  Fluorescence in situ hybridization to improve the diagnosis of endocarditis: a pilot study.

Authors:  C Mallmann; S Siemoneit; D Schmiedel; A Petrich; D M Gescher; E Halle; M Musci; R Hetzer; U B Göbel; A Moter
Journal:  Clin Microbiol Infect       Date:  2009-08-20       Impact factor: 8.067

View more
  3 in total

Review 1.  Ventilator-Associated Pneumonia: The Role of Emerging Diagnostic Technologies.

Authors:  Marin H Kollef; Carey-Ann D Burnham
Journal:  Semin Respir Crit Care Med       Date:  2017-06-04       Impact factor: 3.119

Review 2.  Early appropriate diagnostics and treatment of MDR Gram-negative infections.

Authors:  Matteo Bassetti; Souha S Kanj; Pattarachai Kiratisin; Camilla Rodrigues; David Van Duin; María Virginia Villegas; Yunsong Yu
Journal:  JAC Antimicrob Resist       Date:  2022-09-13

3.  NOTIFy (non-toxic lyophilized field)-FISH for the identification of biological agents by Fluorescence in situ Hybridization.

Authors:  Karin Aistleitner; Tina Sieper; Inga Stürz; Rimma Jeske; Susanne Tritscheller; Sonja Mantel; Alina Tscherne; Sabine Zange; Kilian Stoecker; Roman Wölfel
Journal:  PLoS One       Date:  2020-03-06       Impact factor: 3.240

  3 in total