Literature DB >> 26213717

Cuff-Free Blood Pressure Estimation Using Pulse Transit Time and Heart Rate.

Ruiping Wang1, Wenyan Jia2, Zhi-Hong Mao3, Robert J Sclabassi4, Mingui Sun5.   

Abstract

It has been reported that the pulse transit time (PTT), the interval between the peak of the R-wave in electrocardiogram (ECG) and the fingertip photoplethysmogram (PPG), is related to arterial stiffness, and can be used to estimate the systolic blood pressure (SBP) and diastolic blood pressure (DBP). This phenomenon has been used as the basis to design portable systems for continuously cuff-less blood pressure measurement, benefiting numerous people with heart conditions. However, the PTT-based blood pressure estimation may not be sufficiently accurate because the regulation of blood pressure within the human body is a complex, multivariate physiological process. Considering the negative feedback mechanism in the blood pressure control, we introduce the heart rate (HR) and the blood pressure estimate in the previous step to obtain the current estimate. We validate this method using a clinical database. Our results show that the PTT, HR and previous estimate reduce the estimated error significantly when compared to the conventional PTT estimation approach (p<0.05).

Entities:  

Keywords:  ECG signal; arterial blood pressure; fingertip Photoplethysmogram; pulse transit time

Year:  2014        PMID: 26213717      PMCID: PMC4512231          DOI: 10.1109/ICOSP.2014.7014980

Source DB:  PubMed          Journal:  Int Conf Signal Process Proc


  7 in total

1.  An evaluation of the cuffless blood pressure estimation based on pulse transit time technique: a half year study on normotensive subjects.

Authors:  Mico Yee-Man Wong; Carmen Chung-Yan Poon; Yuan-Ting Zhang
Journal:  Cardiovasc Eng       Date:  2009-03

2.  Critical care: the eight vital signs of patient monitoring.

Authors:  Malcolm Elliott; Alysia Coventry
Journal:  Br J Nurs       Date:  2012 May 24-Jun 13

Review 3.  The Heart Rhythm Society (HRS)/American Society of Anesthesiologists (ASA) Expert Consensus Statement on the perioperative management of patients with implantable defibrillators, pacemakers and arrhythmia monitors: facilities and patient management this document was developed as a joint project with the American Society of Anesthesiologists (ASA), and in collaboration with the American Heart Association (AHA), and the Society of Thoracic Surgeons (STS).

Authors:  George H Crossley; Jeanne E Poole; Marc A Rozner; Samuel J Asirvatham; Alan Cheng; Mina K Chung; T Bruce Ferguson; John D Gallagher; Michael R Gold; Robert H Hoyt; Samuel Irefin; Fred M Kusumoto; Liza Prudente Moorman; Annemarie Thompson
Journal:  Heart Rhythm       Date:  2011-07       Impact factor: 6.343

4.  Cuffless differential blood pressure estimation using smart phones.

Authors:  Vikram Chandrasekaran; Ram Dantu; Srikanth Jonnada; Shanti Thiyagaraja; Kalyan Pathapati Subbu
Journal:  IEEE Trans Biomed Eng       Date:  2012-08-01       Impact factor: 4.538

5.  Measurements of Young's modulus of elasticity of the canine aorta with ultrasound.

Authors:  D J Hughes; C F Babbs; L A Geddes; J D Bourland
Journal:  Ultrason Imaging       Date:  1979-10       Impact factor: 1.578

Review 6.  The relationship of cardiac output and arterial pressure control.

Authors:  A C Guyton
Journal:  Circulation       Date:  1981-12       Impact factor: 29.690

Review 7.  Noninvasive continuous hemodynamic monitoring.

Authors:  Jasper Truijen; Johannes J van Lieshout; Wilbert A Wesselink; Berend E Westerhof
Journal:  J Clin Monit Comput       Date:  2012-06-14       Impact factor: 2.502

  7 in total
  16 in total

1.  Comparison of short-term heart rate variability indexes evaluated through electrocardiographic and continuous blood pressure monitoring.

Authors:  Riccardo Pernice; Michal Javorka; Jana Krohova; Barbora Czippelova; Zuzana Turianikova; Alessandro Busacca; Luca Faes
Journal:  Med Biol Eng Comput       Date:  2019-02-07       Impact factor: 2.602

2.  The B-Score is a novel metric for measuring the true performance of blood pressure estimation models.

Authors:  Tomas L Bothe; Andreas Patzak; Niklas Pilz
Journal:  Sci Rep       Date:  2022-07-16       Impact factor: 4.996

Review 3.  A Wearable Tele-Health System towards Monitoring COVID-19 and Chronic Diseases.

Authors:  Wei Jiang; Sumit Majumder; Samarth Kumar; Sophini Subramaniam; Xiaohe Li; Ridha Khedri; Tapas Mondal; Mansour Abolghasemian; Imran Satia; M Jamal Deen
Journal:  IEEE Rev Biomed Eng       Date:  2022-01-20

4.  Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation.

Authors:  Xiaorong Ding; Bryan P Yan; Yuan-Ting Zhang; Jing Liu; Ni Zhao; Hon Ki Tsang
Journal:  Sci Rep       Date:  2017-09-14       Impact factor: 4.379

5.  Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects.

Authors:  Robert Koprowski; Lei Tian
Journal:  J Ophthalmol       Date:  2017-01-30       Impact factor: 1.909

6.  Blood Pressure Estimation Using Photoplethysmography Only: Comparison between Different Machine Learning Approaches.

Authors:  Syed Ghufran Khalid; Jufen Zhang; Fei Chen; Dingchang Zheng
Journal:  J Healthc Eng       Date:  2018-10-23       Impact factor: 2.682

7.  A Feasibility Study of Non-Invasive Continuous Estimation of Brachial Pressure Derived From Arterial and Venous Lines During Dialysis.

Authors:  Jill Stewart; Paul Stewart; Thomas Walker; Daniela Viramontes Horner; Bethany Lucas; Kelly White; Andy Muggleton; Mel Morris; Nicholas M Selby; Maarten W Taal
Journal:  IEEE J Transl Eng Health Med       Date:  2020-11-04       Impact factor: 3.316

8.  Variability of peripheral pulse wave velocity in patients with diabetes mellitus type 2 during orthostatic challenge.

Authors:  J Svačinová; J Hrušková; J Jakubík; K Budinskaya; S Hidegová; M Fabšík; H Sieglová; Z Kaščáková; J Novák; Z Nováková
Journal:  Physiol Res       Date:  2020-12-31       Impact factor: 1.881

9.  Cuffless Blood Pressure Measurement Using a Smartphone-Case Based ECG Monitor with Photoplethysmography in Hypertensive Patients.

Authors:  Zhanna Sagirova; Natalia Kuznetsova; Nana Gogiberidze; Daria Gognieva; Aleksandr Suvorov; Petr Chomakhidze; Stefano Omboni; Hugo Saner; Philippe Kopylov
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.576

10.  Can Photoplethysmography Replace Arterial Blood Pressure in the Assessment of Blood Pressure?

Authors:  Gloria Martínez; Newton Howard; Derek Abbott; Kenneth Lim; Rabab Ward; Mohamed Elgendi
Journal:  J Clin Med       Date:  2018-09-30       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.