Literature DB >> 26213695

QuantitativeT2: interactive quantitative T2 MRI witnessed in mouse glioblastoma.

Tonima Sumya Ali1, Thorarin Albert Bjarnason2, Donna L Senger3, Jeff F Dunn4, Jeffery T Joseph5, Joseph Ross Mitchell6.   

Abstract

The aim of this study was to establish an advanced analytical platform for complex in vivo pathologies. We have developed a software program, QuantitativeT2, for voxel-based real-time quantitative T2 magnetic resonance imaging. We analyzed murine brain tumors to confirm feasibility of our method for neurological conditions. Anesthetized mice (with invasive gliomas, and controls) were imaged on a 9.4 Tesla scanner using a Carr-Purcell-Meiboom-Gill sequence. The multiecho T2 decays from axial brain slices were analyzed using QuantitativeT2. T2 distribution histograms demonstrated substantial characteristic differences between normal and pathological brain tissues. Voxel-based quantitative maps of tissue water fraction (WF) and geometric mean T2 (gmT2) revealed the heterogeneous alterations to water compartmentalization caused by pathology. The numeric distribution of WF and gmT2 indicated the extent of tumor infiltration. Relative evaluations between in vivo scans and ex vivo histology indicated that the T2s between 30 and 150 ms were related to cellular density and the integrity of the extracellular matrix. Overall, QuantitativeT2 has demonstrated significant advancements in qT2 analysis with real-time operation. It is interactive with an intuitive workflow; can analyze data from many MR manufacturers; and is released as open-source code to encourage examination, improvement, and expansion of this method.

Entities:  

Keywords:  QuantitativeT2; glioblastoma; magnetic resonance imaging; qT2; software

Year:  2015        PMID: 26213695      PMCID: PMC4509667          DOI: 10.1117/1.JMI.2.3.036002

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  30 in total

1.  Myelin water imaging of multiple sclerosis at 7 T: correlations with histopathology.

Authors:  Cornelia Laule; Piotr Kozlowski; Esther Leung; David K B Li; Alex L Mackay; G R Wayne Moore
Journal:  Neuroimage       Date:  2008-03-05       Impact factor: 6.556

2.  In vivo multiecho T2 relaxation measurements using variable TR to decrease scan time.

Authors:  Cornelia Laule; Shannon Heather Kolind; Thorarin Albert Bjarnason; David Kwok Boon Li; Alex Lloyd MacKay
Journal:  Magn Reson Imaging       Date:  2007-05-04       Impact factor: 2.546

3.  Prostate magnetic resonance imaging: multiexponential T2 decay in prostate tissue.

Authors:  Tryggve H Storås; Kjell-Inge Gjesdal; Øystein B Gadmar; Jonn T Geitung; Nils-Einar Kløw
Journal:  J Magn Reson Imaging       Date:  2008-11       Impact factor: 4.813

4.  A new magnetic resonance imaging approach for discriminating Sardinian sheep milk cheese made from heat-treated or raw milk.

Authors:  G Mulas; T Roggio; S Uzzau; R Anedda
Journal:  J Dairy Sci       Date:  2013-10-11       Impact factor: 4.034

5.  Temporal phase correction of multiple echo T2 magnetic resonance images.

Authors:  Thorarin A Bjarnason; Cornelia Laule; Joel Bluman; Piotr Kozlowski
Journal:  J Magn Reson       Date:  2013-03-16       Impact factor: 2.229

6.  Normal-appearing white matter in patients with phenylketonuria: water content, myelin water fraction, and metabolite concentrations.

Authors:  Sandra M Sirrs; Cornelia Laule; Burkhard Mädler; Elana E Brief; Sumia A Tahir; Carole Bishop; Alex L MacKay
Journal:  Radiology       Date:  2007-01       Impact factor: 11.105

Review 7.  Molecular mechanisms of glioma cell migration and invasion.

Authors:  Tim Demuth; Michael E Berens
Journal:  J Neurooncol       Date:  2004-11       Impact factor: 4.130

8.  Insights into brain microstructure from the T2 distribution.

Authors:  Alex MacKay; Cornelia Laule; Irene Vavasour; Thorarin Bjarnason; Shannon Kolind; Burkhard Mädler
Journal:  Magn Reson Imaging       Date:  2006-03-20       Impact factor: 2.546

9.  Multiexponential proton spin-spin relaxation in MR imaging of human brain tumors.

Authors:  L R Schad; G Brix; I Zuna; W Härle; W J Lorenz; W Semmler
Journal:  J Comput Assist Tomogr       Date:  1989 Jul-Aug       Impact factor: 1.826

10.  Evidence of multiexponential T2 in rat glioblastoma.

Authors:  Richard D Dortch; Thomas E Yankeelov; Zoe Yue; Christopher C Quarles; John C Gore; Mark D Does
Journal:  NMR Biomed       Date:  2009-07       Impact factor: 4.044

View more
  2 in total

1.  Correcting for imaging gradients-related bias of T2 relaxation times at high-resolution MRI.

Authors:  Natalie Bnaiahu; Noam Omer; Ella Wilczynski; Shir Levy; Tamar Blumenfeld-Katzir; Noam Ben-Eliezer
Journal:  Magn Reson Med       Date:  2022-06-06       Impact factor: 3.737

2.  Development and validation of a new MRI simulation technique that can reliably estimate optimal in vivo scanning parameters in a glioblastoma murine model.

Authors:  Andrea Protti; Kristen L Jones; Dennis M Bonal; Lei Qin; Letterio S Politi; Sasha Kravets; Quang-Dé Nguyen; Annick D Van den Abbeele
Journal:  PLoS One       Date:  2018-07-23       Impact factor: 3.240