Literature DB >> 17482413

In vivo multiecho T2 relaxation measurements using variable TR to decrease scan time.

Cornelia Laule1, Shannon Heather Kolind, Thorarin Albert Bjarnason, David Kwok Boon Li, Alex Lloyd MacKay.   

Abstract

Multiecho T2 relaxation measurements to determine geometric mean T2 (GMT2) and myelin water fraction (MWF) are lengthy, resulting in increased motion artefacts from patient discomfort and reduced patient compliance. The goal of this study was to shorten the acquisition time for multiecho T2 measurements without affecting T1 weighting by varying TR across k-space. Six phantoms and 10 healthy volunteers were imaged with both a constant TR and a variable TR multiecho T2 sequence. T1 weighting was determined by TR at the center of k-space; for variable TR measurement, TR was shortened linearly from the center to the edges of k-space. Phantoms showed excellent agreement for proton density and GMT2 between constant and variable TR measurements. No significant differences were found in proton density or MWF for any of the brain structures between the two measurements. The average GMT2 over all structures between the two experiments was not significantly different. In summary, with the variable TR approach, scan time was reduced by >20%, with minimal loss of image resolution and no significant affect on proton density, MWF or GMT2.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17482413     DOI: 10.1016/j.mri.2007.02.016

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  7 in total

Review 1.  Inferring brain tissue composition and microstructure via MR relaxometry.

Authors:  Mark D Does
Journal:  Neuroimage       Date:  2018-01-02       Impact factor: 6.556

2.  Temporal phase correction of multiple echo T2 magnetic resonance images.

Authors:  Thorarin A Bjarnason; Cornelia Laule; Joel Bluman; Piotr Kozlowski
Journal:  J Magn Reson       Date:  2013-03-16       Impact factor: 2.229

3.  QuantitativeT2: interactive quantitative T2 MRI witnessed in mouse glioblastoma.

Authors:  Tonima Sumya Ali; Thorarin Albert Bjarnason; Donna L Senger; Jeff F Dunn; Jeffery T Joseph; Joseph Ross Mitchell
Journal:  J Med Imaging (Bellingham)       Date:  2015-07-21

4.  Characterization of brain tumours with spin-spin relaxation: pilot case study reveals unique T 2 distribution profiles of glioblastoma, oligodendroglioma and meningioma.

Authors:  Cornelia Laule; Thorarin A Bjarnason; Irene M Vavasour; Anthony L Traboulsee; G R Wayne Moore; David K B Li; Alex L MacKay
Journal:  J Neurol       Date:  2017-09-11       Impact factor: 4.849

5.  48 echo T₂ myelin imaging of white matter in first-episode schizophrenia: evidence for aberrant myelination.

Authors:  Donna J M Lang; Eugene Yip; Alexander L MacKay; Allen E Thornton; Fidel Vila-Rodriguez; G William MacEwan; Lili C Kopala; Geoffrey N Smith; Cornelia Laule; Cassie B MacRae; William G Honer
Journal:  Neuroimage Clin       Date:  2014-10-15       Impact factor: 4.881

6.  A new analysis approach for T2 relaxometry myelin water quantification: Orthogonal Matching Pursuit.

Authors:  Gerhard S Drenthen; Walter H Backes; Albert P Aldenkamp; Giel J Op 't Veld; Jacobus F A Jansen
Journal:  Magn Reson Med       Date:  2018-11-16       Impact factor: 4.668

7.  Comparison of multi echo T2 relaxation and steady state approaches for myelin imaging in the central nervous system.

Authors:  Adam V Dvorak; Emil Ljungberg; Irene M Vavasour; Lisa Eunyoung Lee; Shawna Abel; David K B Li; Anthony Traboulsee; Alex L MacKay; Shannon H Kolind
Journal:  Sci Rep       Date:  2021-01-14       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.