Literature DB >> 26204980

The effects of the Frag-Loc(®) compression screw on distal radius fracture with a displaced dorsoulnar fragment.

Jung Il Lee1, Jung Hyun Cho, Seoung Joon Lee.   

Abstract

PURPOSE: The purpose of this study is to evaluate the radiographic and clinical outcomes of the Frag-Loc(®) compression screw with palmar plate fixation on distal radius fractures that include a displaced dorsoulnar fragment. PATIENTS AND METHODS: This retrospective comparative study enrolled 48 patients who had an unstable distal radius fracture and a dorsoulnar fragment that was more than 2 mm displaced and that had involvement of more than one-quarter of the articular surface. Twenty-six of the 48 patients were treated with a palmar locking plate without a Frag-Loc(®) compression screw (group 1) and the other 22 patients were treated with palmar locking plate with a Frag-Loc(®) compression screw to fix the dorsoulnar fragment (group 2). First, we reviewed all pre-surgical computerized tomographic (CT) scans. Second, we used the gap distance between the dorsoulnar and palmar fragment as seen on post-surgical axial and sagittal CT scans to determine outcome. The gap distance was measured at the point of maximum distance perpendicular to the plane of the main fracture line. Clinical outcomes were evaluated based on the patient-rated wrist evaluation (PRWE) score; the disabilities of the arm, shoulder and hand score; wrist active range of motion; and grip strength.
RESULTS: There were no statistically significant differences in clinical outcome between the two groups. However, there were statistically significant differences in post-surgical gap distance. The mean post-surgical gap distances for group 1 were 1.3 mm (range 0.2-3.8 mm) on axial CT scans and 1.4 mm (range 0.5-2.4 mm) on sagittal CT scans, while the mean post-surgical gap distances for group 2 were 0.7 mm (range 0.7-1.6 mm) and 0.7 mm (range 0.3-1.1 mm).
CONCLUSION: This study shows that the Frag-Loc(®) compression screw can reduce the gap distance between the dorsoulnar fragment and the distal radius, according to evaluation of post-surgical axial and sagittal CT scans. This result suggests that the Frag-Loc(®) compression screw is an effective and simple treatment option to immobilize a dorsoulnar fragment associated with distal radius fracture.

Entities:  

Mesh:

Year:  2015        PMID: 26204980     DOI: 10.1007/s00402-015-2290-y

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  5 in total

1.  Comparison of Locking and Frag-Loc Screws for Fixation of Die-Punch Fragments.

Authors:  Takaaki Kanazawa; Kazunari Tomita; Keikichi Kawasaki; Toshio Yagi; Yuji Tanabe; Katsunori Inagaki
Journal:  J Wrist Surg       Date:  2017-12-14

Review 2.  [Distal radius fracture of the adult : Diagnostics and therapy].

Authors:  F Unglaub; M F Langer; B Hohendorff; L P Müller; J M Unglaub; P Hahn; H Krimmer; C K Spies
Journal:  Orthopade       Date:  2017-01       Impact factor: 1.087

3.  The Effect of Displaced Dorsal Rim Fragment in a Distal Radius Fracture.

Authors:  Jae Kwang Kim; Yeo-Hon Yun; Dong Jun Kim
Journal:  J Wrist Surg       Date:  2016-01-06

4.  Volar versus combined dorsal and volar plate fixation of complex intraarticular distal radius fractures with small dorsoulnar fragment - a biomechanical study.

Authors:  Mariya Hadzhinikolova; Ivan Zderic; Daniel Ciric; Jan P Barcik; Dian Enchev; Asen Baltov; Lyubomir Rusimov; Peter Varga; Karl Stoffel; Geoff Richards; Boyko Gueorguiev; Mihail Rashkov
Journal:  BMC Musculoskelet Disord       Date:  2022-01-05       Impact factor: 2.362

5.  Lasso loop technique using bioabsorbable thread to treat intra-articular distal radius fracture.

Authors:  Yoshio Kaji; Konosuke Yamaguchi; Yumi Nomura; Kunihiko Oka; Masashi Shimamura; Shohei Kawakami; Tetsuji Yamamoto
Journal:  Medicine (Baltimore)       Date:  2021-11-24       Impact factor: 1.817

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.