Literature DB >> 26204298

Frequency of Malignancy and Imaging Characteristics of Probably Benign Lesions Seen at Breast MRI.

Lars J Grimm1, Andy L Anderson1, Jay A Baker1, Karen S Johnson1, Ruth Walsh1, Sora C Yoon1, Sujata V Ghate1.   

Abstract

OBJECTIVE: The purposes of this study were to evaluate the frequency, follow-up compliance, and cancer rate of MRI BI-RADS category 3 lesions and to determine the cancer rate for individual BI-RADS descriptors.
MATERIALS AND METHODS: A retrospective review was conducted of breast MRI examinations with an assessment of probably benign (BI-RADS category 3) from among 4279 consecutive breast MRI examinations performed from January 2005 through December 2009. The review revealed 282 (6.6%) examinations with 332 lesions defined as BI-RADS 3. Pathologic results, 2 years of follow-up imaging findings, or both were reviewed. The frequency of BI-RADS 3 assessments, follow-up imaging compliance, and cancer yield were calculated. Three fellowship-trained breast imagers reevaluated all lesions and recorded descriptors from the MRI lexicon of the fifth edition of the BI-RADS atlas. The distribution and likelihood of malignancy for each descriptor were calculated.
RESULTS: The follow-up compliance rate was 84.3% (280/332), and the malignancy rate was 4.3% (12/280). There were 50 (17.9%) individual foci, 61 (21.8%) multiple foci, 74 (26.4%) masses, and 95 (33.9%) nonmass enhancement lesions. Masses were most commonly oval (59.5% [44/74]), circumscribed (75.7% [56/74]), and homogeneously enhancing (43.2% [32/74]). Nonmass enhancement was most commonly focal (57.9% [55/95]) with heterogeneous enhancement (53.7% [51/95]) Most of the lesions had persistent kinetics (74.3% [208/280]). The background parenchymal enhancement was most commonly mild (51.1% [143/280]).
CONCLUSION: MRI BI-RADS category 3 is not frequently used, and the levels of patient compliance with follow-up imaging are acceptable. The cancer yield for probably benign lesions is greater for MRI-detected than for mammographically detected lesions, especially for specific BI-RADS descriptors.

Entities:  

Keywords:  BI-RADS; MRI; breast cancer; probably benign

Mesh:

Year:  2015        PMID: 26204298     DOI: 10.2214/AJR.14.13530

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

1.  Management for BI-RADS category 3 lesions detected in preoperative breast MR imaging of breast cancer patients.

Authors:  Hye Mi Gweon; Nariya Cho; Soo-Yeon Kim; Hye Ryoung Koo; Mirinae Seo; Ajung Chu; Eun Ju Son
Journal:  Eur Radiol       Date:  2017-01-12       Impact factor: 5.315

Review 2.  BI-RADS 3 Assessment on MRI: A Lesion-Based Review for Breast Radiologists.

Authors:  Derek L Nguyen; Kelly S Myers; Eniola Oluyemi; Lisa A Mullen; Babita Panigrahi; Joanna Rossi; Emily B Ambinder
Journal:  J Breast Imaging       Date:  2022-06-28

Review 3.  Breast lesions classified as probably benign (BI-RADS 3) on magnetic resonance imaging: a systematic review and meta-analysis.

Authors:  Claudio Spick; Hubert Bickel; Stephan H Polanec; Pascal A Baltzer
Journal:  Eur Radiol       Date:  2017-11-22       Impact factor: 5.315

4.  How I report breast magnetic resonance imaging studies for breast cancer staging and screening.

Authors:  Sarah Vinnicombe
Journal:  Cancer Imaging       Date:  2016-07-25       Impact factor: 3.909

5.  Breast Imaging Reporting and Data Systems category 3 (probably benign) breast lesions detected on diagnostic breast ultrasound: The prevalence, outcome and malignancy detection rate in Zaria, Nigeria.

Authors:  Sefiya A Olarinoye-Akorede; Garba H Yunusa; Halima Aliyu; Ahmed U Hamidu
Journal:  SA J Radiol       Date:  2018-11-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.