Literature DB >> 26199297

Treatment of a dissecting vertebral artery aneurysm with angioplasty and the pipeline embolisation device.

Veer A Shah1, Patrik Leonard1, Jordan Sessions1, William E Holloway1.   

Abstract

A 49-year-old woman was admitted with Hunt and Hess grade 1 subarachnoid haemorrhage. A cerebral aneurysm of the intracranial left vertebral artery (VA) distal to the left posterior inferior cerebellar artery (PICA) was found and treated using parent vessel occlusion with coils. The PICA was preserved. Angiography at three time points during her hospitalisation showed a normal right VA. Eight months later, angiography demonstrated a new 14 mm right VA dissecting aneurysm with 90% outflow stenosis and recurrence of the left VA aneurysm distal to the coils. A Marksman microcatheter would not traverse the stenosis despite the use of two intraluminal wires. Following Gateway balloon (1.5 mm × 9 mm) angioplasty, the Marksman passed easily. The pipeline embolisation device (PED) was successfully deployed across the aneurysm and 11 coils placed through a trapped microcatheter. The patient was discharged home 2 days later. Eighteen-month follow-up has revealed complete resolution of both aneurysms. 2015 BMJ Publishing Group Ltd.

Entities:  

Mesh:

Year:  2015        PMID: 26199297      PMCID: PMC4513573          DOI: 10.1136/bcr-2015-210485

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  16 in total

1.  Delayed ipsilateral parenchymal hemorrhage following flow diversion for the treatment of anterior circulation aneurysms.

Authors:  J P Cruz; M Chow; C O'Kelly; B Marotta; J Spears; W Montanera; D Fiorella; T Marotta
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-08       Impact factor: 3.825

Review 2.  Current imaging assessment and treatment of intracranial aneurysms.

Authors:  Lotfi Hacein-Bey; James M Provenzale
Journal:  AJR Am J Roentgenol       Date:  2011-01       Impact factor: 3.959

3.  De novo vertebral artery dissecting aneurysm after contralateral vertebral artery occlusion--two case reports.

Authors:  Yoshiro Inui; Yoshitsugu Oiwa; Tomoaki Terada; Kazuo Nakakita; Ichiro Kamei; Seiji Hayashi
Journal:  Neurol Med Chir (Tokyo)       Date:  2006-01       Impact factor: 1.742

4.  Incidence and risk factors of recurrence after endovascular treatment of intracranial vertebrobasilar dissecting aneurysms.

Authors:  Byung Moon Kim; Yong Sam Shin; Se-Hyuk Kim; Sang Hyun Suh; Yon-Kwon Ihn; Dong Ik Kim; Dong Joon Kim; Sung Il Park
Journal:  Stroke       Date:  2011-07-21       Impact factor: 7.914

5.  The role of the pipeline embolization device for the treatment of dissecting intracranial aneurysms.

Authors:  M de Barros Faria; R Nella Castro; J Lundquist; E Scrivano; R Ceratto; A Ferrario; P Lylyk
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-01       Impact factor: 3.825

6.  Reconstructive endovascular treatment of a ruptured vertebral artery dissecting aneurysm using the Pipeline embolization device.

Authors:  Andrew F Ducruet; R Webster Crowley; Felipe C Albuquerque; Cameron G McDougall
Journal:  J Neurointerv Surg       Date:  2012-06-20       Impact factor: 5.836

7.  Lesion location, stability, and pretreatment management: factors affecting outcomes of endovascular treatment for vertebrobasilar atherosclerosis.

Authors:  Matthew D Alexander; Jeffrey M Rebhun; Steven W Hetts; Anthony S Kim; Jeffrey Nelson; Helen Kim; Matthew R Amans; Fabio Settecase; Christopher F Dowd; Van V Halbach; Randall T Higashida; Daniel L Cooke
Journal:  J Neurointerv Surg       Date:  2015-03-20       Impact factor: 5.836

8.  Concurrent use of the Pipeline Embolization Device and coils for intracranial aneurysms: technique, safety, and efficacy.

Authors:  Erez Nossek; David J Chalif; Shamik Chakraborty; Kim Lombardo; Karen S Black; Avi Setton
Journal:  J Neurosurg       Date:  2015-02-06       Impact factor: 5.115

9.  Pipeline embolization device in aneurysmal subarachnoid hemorrhage.

Authors:  J P Cruz; C O'Kelly; M Kelly; J H Wong; W Alshaya; A Martin; J Spears; T R Marotta
Journal:  AJNR Am J Neuroradiol       Date:  2012-10-11       Impact factor: 3.825

10.  Pipeline embolization device for the treatment of intra- and extracranial fusiform and dissecting aneurysms: initial experience and long-term follow-up.

Authors:  Sebastian Fischer; Marta Aguilar Perez; Wiebke Kurre; Guido Albes; Hansjörg Bäzner; Hans Henkes
Journal:  Neurosurgery       Date:  2014-10       Impact factor: 4.654

View more