Literature DB >> 26198652

Cone beam computed tomography guided treatment delivery and planning verification for magnetic resonance imaging only radiotherapy of the brain.

Jens M Edmund1, Daniel Andreasen1,2, Faisal Mahmood1, Koen Van Leemput2,3.   

Abstract

BACKGROUND: Radiotherapy based on MRI only (MRI-only RT) shows a promising potential for the brain. Much research focuses on creating a pseudo computed tomography (pCT) from MRI for treatment planning while little attention is often paid to the treatment delivery. Here, we investigate if cone beam CT (CBCT) can be used for MRI-only image-guided radiotherapy (IGRT) and for verifying the correctness of the corresponding pCT.
MATERIAL AND METHODS: Six patients receiving palliative cranial RT were included in the study. Each patient had three-dimensional (3D) T1W MRI, a CBCT and a CT for reference. Further, a pCT was generated using a patch-based approach. MRI, pCT and CT were placed in the same frame of reference, matched to CBCT and the differences noted. Paired pCT-CT and pCT-CBCT data were created in bins of 10 HU and the absolute difference calculated. The data were converted to relative electron densities (RED) using the CT or a CBCT calibration curve. The latter was either based on a CBCT phantom (phan) or a paired CT-CBCT population (pop) of the five other patients.
RESULTS: Non-significant (NS) differences in the pooled CT-CBCT, MRI-CBCT and pCT-CBCT transformations were noted. The largest deviations from the CT-CBCT reference were < 1 mm and 1°. The average median absolute error (MeAE) in HU was 184 ± 34 and 299 ± 34 on average for pCT-CT and pCT-CBCT, respectively, and was significantly different (p < 0.01) in each patient. The average MeAE in RED was 0.108 ± 0.025, 0.104 ± 0.011 and 0.099 ± 0.017 for pCT-CT, pCT-CBCT phan (p < 0.01 on 2 patients) and pCT-CBCT pop (NS), respectively.
CONCLUSIONS: CBCT can be used for patient setup with either MRI or pCT as reference. The correctness of pCT can be verified from CBCT using a population-based calibration curve in the treatment geometry.

Entities:  

Mesh:

Year:  2015        PMID: 26198652     DOI: 10.3109/0284186X.2015.1062546

Source DB:  PubMed          Journal:  Acta Oncol        ISSN: 0284-186X            Impact factor:   4.089


  12 in total

1.  Image Guided Radiation Therapy Using Synthetic Computed Tomography Images in Brain Cancer.

Authors:  Ryan G Price; Joshua P Kim; Weili Zheng; Indrin J Chetty; Carri Glide-Hurst
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-03-10       Impact factor: 7.038

2.  Estimation and evaluation of pseudo-CT images using linear regression models and texture feature extraction from MRI images in the brain region to design external radiotherapy planning.

Authors:  Niloofar Yousefi Moteghaed; Ahmad Mostaar; Keivan Maghooli; Mohammad Houshyari; Ahmad Ameri
Journal:  Rep Pract Oncol Radiother       Date:  2020-07-11

3.  Are cone beam CT image matching skills transferrable from planning CT to planning MRI for MR-only prostate radiotherapy?

Authors:  Rachel L Brooks; Hazel M McCallum; Rachel A Pearson; Karen Pilling; Jonathan Wyatt
Journal:  Br J Radiol       Date:  2021-04-29       Impact factor: 3.039

Review 4.  A review of substitute CT generation for MRI-only radiation therapy.

Authors:  Jens M Edmund; Tufve Nyholm
Journal:  Radiat Oncol       Date:  2017-01-26       Impact factor: 3.481

5.  Assessment of MRI-Based Attenuation Correction for MRI-Only Radiotherapy Treatment Planning of the Brain.

Authors:  Iiro Ranta; Jarmo Teuho; Jani Linden; Riku Klén; Mika Teräs; Mika Kapanen; Jani Keyriläinen
Journal:  Diagnostics (Basel)       Date:  2020-05-14

6.  Cone beam computed tomography for dose calculation quality assurance for magnetic resonance-only radiotherapy.

Authors:  Jonathan J Wyatt; Rachel A Pearson; Christopher P Walker; Rachel L Brooks; Karen Pilling; Hazel M McCallum
Journal:  Phys Imaging Radiat Oncol       Date:  2021-02-02

7.  Prospective Clinical Feasibility Study for MRI-Only Brain Radiotherapy.

Authors:  Minna Lerner; Joakim Medin; Christian Jamtheim Gustafsson; Sara Alkner; Lars E Olsson
Journal:  Front Oncol       Date:  2022-01-10       Impact factor: 6.244

8.  MRI-Only Radiotherapy Planning for Nasopharyngeal Carcinoma Using Deep Learning.

Authors:  Xiangyu Ma; Xinyuan Chen; Jingwen Li; Yu Wang; Kuo Men; Jianrong Dai
Journal:  Front Oncol       Date:  2021-09-08       Impact factor: 6.244

9.  Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis.

Authors:  Jens M Edmund; Daniel Andreasen; Koen Van Leemput
Journal:  Phys Imaging Radiat Oncol       Date:  2021-05-13

10.  Cone beam CT for QA of synthetic CT in MRI only for prostate patients.

Authors:  Emilia Palmér; Emilia Persson; Petra Ambolt; Christian Gustafsson; Adalsteinn Gunnlaugsson; Lars E Olsson
Journal:  J Appl Clin Med Phys       Date:  2018-09-04       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.