Literature DB >> 26188497

A highly sensitive and flexible magnetic nanoprobe labeled immunochromatographic assay platform for pathogen Vibrio parahaemolyticus.

Yingying Liu1, Zhaohuan Zhang1, Yilong Wang2, Yong Zhao1, Ying Lu3, Xiaowei Xu1, Jun Yan1, Yingjie Pan1.   

Abstract

A magnetic nanoprobe labeled immunochromatographic test strip (MNP/ICTS) was developed to detect food-borne pathogen Vibrio parahaemolyticus. Specific antibody against V. parahaemolyticus was used as test line by coating onto the nitrocellulose membrane. Magnetic nanoprobe was prepared by immobilizing the specific antibody onto the surface of superparamagnetic nanoparticles. Specificity and sensitivity of the MNP/ICTS system were verified by artificially contaminated shrimp homogenate samples. Reliability and application feasibility of the MNP/ICTS system were demonstrated by using seafood samples (n=36). Comparing with polymerase chain reaction (PCR) and traditional culture methods, the MNP/ICTS system is found to be not only a rapid qualitative analysis (~10 min), but also an accurately quantitative detection platform. Through its rapid magnetic separation property, the MNP/ICTS system is capable to flexibly combine with a sample enrichment and pre-incubation process. This combination makes the qualitative sensitivity for the food samples surged more than 100-fold. A naked-eye observation of 1.58×10(2) CFU/g V. parahaemolyticus was realized. This sensitivity could meet the V. parahaemolyticus test threshold value in many countries. Also, the total sample pre-treatment plus MNP/ICTS assay only needs about 4.5h. Namely, we can get test results in a day. Hence, the developed MNP/ICTS assay platform is simple, rapid and highly sensitive. It is a flexible test platform for pathogen detection. The favorable comparison with PCR and culture methods further proves that the developed MNP/ICTS is applicable into food-borne pathogen or other areas where a simple, rapid, sensitive and point-of-care analysis is desirable.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Immunochromatographic test strip; Magnetic nanoprobe; Sensitive detection; Vibrio parahaemolyticus

Mesh:

Year:  2015        PMID: 26188497     DOI: 10.1016/j.ijfoodmicro.2015.07.005

Source DB:  PubMed          Journal:  Int J Food Microbiol        ISSN: 0168-1605            Impact factor:   5.277


  8 in total

Review 1.  Inorganic Complexes and Metal-Based Nanomaterials for Infectious Disease Diagnostics.

Authors:  Christine F Markwalter; Andrew G Kantor; Carson P Moore; Kelly A Richardson; David W Wright
Journal:  Chem Rev       Date:  2018-12-04       Impact factor: 60.622

2.  A Fluorescence Immunochromatographic Assay Using Europium (III) Chelate Microparticles for Rapid, Quantitative and Sensitive Detection of Creatine Kinase MB.

Authors:  Xiao-Hong Lai; Rong-Liang Liang; Tian-Cai Liu; Zhi-Ning Dong; Ying-Song Wu; Lin-Hai Li
Journal:  J Fluoresc       Date:  2016-04-01       Impact factor: 2.217

3.  Ag Nanoparticles with Ultrathin Au Shell-Based Lateral Flow Immunoassay for Colorimetric and SERS Dual-Mode Detection of SARS-CoV-2 IgG.

Authors:  Penghui Liang; Qi Guo; Tianyu Zhao; Cong-Ying Wen; Zhangyu Tian; Yanxue Shang; Jinyan Xing; Yongzhong Jiang; Jingbin Zeng
Journal:  Anal Chem       Date:  2022-06-03       Impact factor: 8.008

4.  Development and evaluation of a rapid and sensitive RPA assay for specific detection of Vibrio parahaemolyticus in seafood.

Authors:  Yunyun Geng; Ke Tan; Libing Liu; Xiao Xia Sun; Baohua Zhao; Jianchang Wang
Journal:  BMC Microbiol       Date:  2019-08-13       Impact factor: 3.605

5.  Multiplex Recombinase Polymerase Amplification Assay for the Simultaneous Detection of Three Foodborne Pathogens in Seafood.

Authors:  Biao Ma; Jiali Li; Kai Chen; Xiaoping Yu; Chuanxin Sun; Mingzhou Zhang
Journal:  Foods       Date:  2020-03-03

6.  Advanced trap lateral flow immunoassay sensor for the detection of cortisol in human bodily fluids.

Authors:  Hyun-Kyung Oh; Kihyeun Kim; Jinhee Park; Hyungjun Jang; Min-Gon Kim
Journal:  Sci Rep       Date:  2021-11-19       Impact factor: 4.379

Review 7.  Magnetic Lateral Flow Immunoassays.

Authors:  Amanda Moyano; Esther Serrano-Pertierra; María Salvador; José Carlos Martínez-García; Montserrat Rivas; M Carmen Blanco-López
Journal:  Diagnostics (Basel)       Date:  2020-05-08

8.  A Rapid Immunochromatographic Method Based on a Secondary Antibody-Labelled Magnetic Nanoprobe for the Detection of Hepatitis B preS2 Surface Antigen.

Authors:  Yangyang Cai; Jun Yan; Li Zhu; Hengliang Wang; Ying Lu
Journal:  Biosensors (Basel)       Date:  2020-10-31
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.