Automatic Measurement of Venous Pressure Using B-Mode Ultrasound.

Alessandro Crimi, Maxim Makhinya, Ulrich Baumann, Christoph Thalhammer, Gabor Szekely, Orcun Goksel.   

Abstract

Central venous pressure (CVP) information is crucial in clinical situations, such as cardiac failure, intravascular volume overload, and sepsis. The measurement of CVP, however, requires the catheterization of vena cava through the subclavian or internal jugular veins, which is an impractical and costly procedure with related risk of complications. Peripheral venous pressure (PVP), which correlates with CVP under certain patient positioning, can be measured noninvasively using ultrasound via controlled compressions of a superficial vein. This paper presents an automatic system for acquiring such noninvasive measurements. Robust signal and image processing techniques developed for this purpose are introduced in this paper. The proposed standalone mobile platform collects images in real time from the display output of any ultrasound machine, meanwhile measuring the pressure on the skin underneath the ultrasound transducer via a liquid-filled pouch. The image and pressure data are synchronized through an automated temporal calibration procedure. During forearm compressions, blood vessels are detected and tracked in the images using robust geometric (ellipse) models, the parameters of which are used further in the model-based estimation of PVP. The proposed system was tested in 56 image sequences on 14 healthy volunteers, and was shown to achieve measurements with errors comparable to or lower than the interoperator variability of expert manual assessments.

Entities:  

Mesh:

Year:  2015        PMID: 26186764     DOI: 10.1109/TBME.2015.2455953

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  2 in total

1.  Robust motion tracking in liver from 2D ultrasound images using supporters.

Authors:  Ece Ozkan; Christine Tanner; Matej Kastelic; Oliver Mattausch; Maxim Makhinya; Orcun Goksel
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-03-22       Impact factor: 2.924

2.  Commercial Devices-Based System Designed to Improve the Treatment Adherence of Hypertensive Patients.

Authors:  Vandermi João da Silva; Vinicius da Silva Souza; Robson Guimarães da Cruz; Juliana Mesquita Vidal Martinez de Lucena; Nasser Jazdi; Vicente Ferreira de Lucena Junior
Journal:  Sensors (Basel)       Date:  2019-10-18       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.