Literature DB >> 26185132

The Impact of Stent Graft Material on the Inflammatory Response After EVAR.

Fredrik Sartipy1, David Lindström2, Peter Gillgren3, Anders Ternhag4.   

Abstract

BACKGROUND: Patients undergoing endovascular aneurysm repair (EVAR) due to abdominal aortic aneurysm often develop an inflammatory response, postimplantation syndrome (PIS) where fever and leukocytosis are common. Previous studies suggest that type of stent graft material (polyester or polytetrafluoroethylene [PTFE]) plays a role.
OBJECTIVES: To investigate the effect of stent graft material on the inflammatory response and length of hospital stay in patients undergoing standard elective EVAR.
METHODS: Sixty-nine elective EVAR patients were included in this observational study. To avoid comparing patients with a different graft location and stent graft burden, 12 cases were excluded as well as cases with complication or simultaneous open surgical procedures, leaving 45 patients (32 with polyester and 13 with PTFE graft) for final analysis. Tympanic temperature, C-reactive protein (CRP), white blood cell (WBC), and procalcitonin (PCT) were measured on days -1 and +1 and +3. Duration of in-hospital stay and frequency of PIS were recorded.
RESULTS: The PIS was diagnosed in 9 (28.1%) of the 32 polyester cases and in 1 (7.7%) of the 13 cases in the PTFE group (P = .24). Median (interquartile range) in-hospital stay was 5 (5-6) days in the polyester group and 4 (4-5) days in the PTFE group (P = .009). On day +3, in the polyester group, mean CRP was 154 (95% confidence interval: 127-182) mg/L, WBC 9.5 (8.4-10.5) ×10(9)/L, and PCT 0.17 (0.12-0.21) ng/mL. In the PTFE group, mean CRP was 70 (32-109) mg/L (P = .001), WBC 8.8 (6.4-11.1) ×10(9)/L (P = .37), and PCT 0.09 (0.06-0.13) ng/mL (P = .009) on day +3.
CONCLUSION: Standard EVAR with polyester stent grafts appears to result in a trend toward a more pronounced inflammatory reaction than similar EVAR using PTFE and is associated with a longer in-hospital stay.
© The Author(s) 2015.

Entities:  

Keywords:  EVAR; inflammatory; material; postimplantation syndrome; procalcitonin; stentgraft

Mesh:

Substances:

Year:  2015        PMID: 26185132     DOI: 10.1177/1538574415595209

Source DB:  PubMed          Journal:  Vasc Endovascular Surg        ISSN: 1538-5744            Impact factor:   1.089


  4 in total

Review 1.  Endovascular Management of Abdominal Aortic Aneurysms: the Year in Review.

Authors:  John E O'Mara; Robert M Bersin
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-08

Review 2.  The contemporary design of endovascular aneurysm stent-graft materials: PTFE versus polyester.

Authors:  Niamh Hynes; Yogesh Acharya; Sherif Sultan
Journal:  Front Surg       Date:  2022-08-16

Review 3.  TEVAR and EVAR, the unknown knowns of the cardiovascular hemodynamics; and the immediate and long-term consequences of fabric material on major adverse clinical outcome.

Authors:  Sherif Sultan; Yogesh Acharya; Osama Soliman; Juan Carlos Parodi; Niamh Hynes
Journal:  Front Surg       Date:  2022-08-30

Review 4.  Platelet function changes in patients undergoing endovascular aortic aneurysm repair: Review of the literature.

Authors:  Anna Burban; Aleksandra Idzik; Agata Gelo; Krzysztof J Filipiak; Tomasz Jakimowicz; Katarzyna Jama; Marcin Grabowski; Aleksandra Gasecka; Aleksander Siniarski
Journal:  Front Cardiovasc Med       Date:  2022-08-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.