Endovascular Management of Abdominal Aortic Aneurysms: the Year in Review.

John E O'Mara1, Robert M Bersin2.   

Abstract

OPINION STATEMENT: Endovascular aneurysm repair (EVAR) has become the predominant method of treatment for abdominal aortic aneurysms (AAA). The use of conscious sedation with local anesthesia and percutaneous femoral access has further decreased the morbidity of the procedure. Current devices can more effectively manage increasingly "hostile" aneurysm necks, while chimney grafts or dedicated fenestrated stent-grafts can be used for juxta-renal disease with favorable results. However, endovascular repair does present a new set of challenges, and endoleaks remain an area of concern. While there is general consensus that type I and type III endoleaks require treatment, type II endoleaks are the topic of ongoing research and debate. Development of devices and techniques to prevent and treat endoleak continues to progress. Advances in contrast-enhanced ultrasound are reducing reliance on computed tomography for post-operative monitoring. This is an important step in this population at high risk for the development of kidney failure. Despite these many innovations, further research is needed to optimize the care of patients with AAA.

Entities:  

Keywords:  Abdominal aortic aneurysm; Endoleak; Endovascular procedures

Year:  2016        PMID: 27376647     DOI: 10.1007/s11936-016-0470-x

Source DB:  PubMed          Journal:  Curr Treat Options Cardiovasc Med        ISSN: 1092-8464


  79 in total

Review 1.  Contrast-enhanced ultrasound (CEUS) versus computed tomography angiography (CTA) in detection of endoleaks in post-EVAR patients. Are delayed type II endoleaks being missed? A systematic review and meta-analysis.

Authors:  J Chung; A Kordzadeh; I Prionidis; Y Panayiotopoulos; T Browne
Journal:  J Ultrasound       Date:  2015-01-17

2.  Development of tissue-engineered self-expandable aortic stent grafts (Bio stent grafts) using in-body tissue architecture technology in beagles.

Authors:  Hidetake Kawajiri; Takeshi Mizuno; Takeshi Moriwaki; Hatsue Ishibashi-Ueda; Masashi Yamanami; Keiichi Kanda; Hitoshi Yaku; Yasuhide Nakayama
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2014-06-03       Impact factor: 3.368

3.  Risk factors associated with late aneurysmal sac expansion after endovascular abdominal aortic aneurysm repair.

Authors:  Motoki Nakai; Akira Ikoma; Hirotatsu Sato; Morio Sato; Yoshiharu Nishimura; Yoshitaka Okamura
Journal:  Diagn Interv Radiol       Date:  2015 May-Jun       Impact factor: 2.630

4.  Outcome-based anatomic criteria for defining the hostile aortic neck.

Authors:  William D Jordan; Kenneth Ouriel; Manish Mehta; David Varnagy; William M Moore; Frank R Arko; James Joye; Jean-Paul P M de Vries
Journal:  J Vasc Surg       Date:  2015-02-28       Impact factor: 4.268

5.  Endovascular Repair of Abdominal Aortic Aneurysms with the Anaconda™ Stent Graft: Mid-term Results from a Single Center.

Authors:  Christos D Karkos; Dimitrios M Kapetanios; Prodromos Th Anastasiadis; Foteini S Grigoropoulou; Thomas E Kalogirou; Ioakeim T Giagtzidis; Konstantinos O Papazoglou
Journal:  Cardiovasc Intervent Radiol       Date:  2015-03-24       Impact factor: 2.740

6.  Predictors of Failure of Closure in Percutaneous EVAR Using the Prostar XL Percutaneous Vascular Surgery Device.

Authors:  M P Rijkée; R G Statius van Eps; J J Wever; H van Overhagen; L C van Dijk; B Knippenberg
Journal:  Eur J Vasc Endovasc Surg       Date:  2015-01       Impact factor: 7.069

7.  Outcomes of persistent intraoperative type Ia endoleak after standard endovascular aneurysm repair.

Authors:  Alistair M Millen; Khabab Osman; George A Antoniou; Richard G McWilliams; John A Brennan; Robert K Fisher
Journal:  J Vasc Surg       Date:  2015-02-02       Impact factor: 4.268

8.  Length of abdominal aortic aneurysm and incidence of endoleaks type II after endovascular repair.

Authors:  Dinh Dong Nghi Phan; Frank Meyer; Maciej Pech; Zuhir Halloul
Journal:  Wien Klin Wochenschr       Date:  2015-11-05       Impact factor: 1.704

Review 9.  Systematic Review and Meta-analysis of Long-term survival After Elective Infrarenal Abdominal Aortic Aneurysm Repair 1969-2011: 5 Year Survival Remains Poor Despite Advances in Medical Care and Treatment Strategies.

Authors:  S S Bahia; P J E Holt; D Jackson; B O Patterson; R J Hinchliffe; M M Thompson; A Karthikesalingam
Journal:  Eur J Vasc Endovasc Surg       Date:  2015-06-23       Impact factor: 7.069

10.  Evaluation of the Zenith low-profile abdominal aortic aneurysm stent graft.

Authors:  Jonathan Sobocinski; Florent Briffa; Peter J Holt; Teresa Martin Gonzalez; Rafaëlle Spear; Richard Azzaoui; Blandine Maurel; Stéphan Haulon
Journal:  J Vasc Surg       Date:  2015-08-01       Impact factor: 4.268

View more
  3 in total

1.  3D Printed Abdominal Aortic Aneurysm Phantom for Image Guided Surgical Planning with a Patient Specific Fenestrated Endovascular Graft System.

Authors:  Karen M Meess; Richard L Izzo; Maciej L Dryjski; Richard E Curl; Linda M Harris; Michael Springer; Adnan H Siddiqui; Stephen Rudin; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-13

2.  Mortality, Length of Stay, and Cost Implications of Procedural Bleeding After Percutaneous Interventions Using Large-Bore Catheters.

Authors:  Björn Redfors; Brendan M Watson; Thomas McAndrew; Emilie Palisaitis; Dominic P Francese; Mehdi Razavi; Jordan Safirstein; Roxana Mehran; Ajay J Kirtane; Philippe Généreux
Journal:  JAMA Cardiol       Date:  2017-07-01       Impact factor: 14.676

3.  Post-Traumatic Ostial Avulsion of a Polar Inferior Renal Artery Treated by Endovascular Covered Aortic Stenting.

Authors:  François Carrozza; Fabrice C Deprez
Journal:  J Belg Soc Radiol       Date:  2020-05-07       Impact factor: 1.894

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.