Abstract
Contrast-enhanced ultrasound (CEUS) has recently become one of the most versatile and powerful diagnostic tools in vascular surgery. One of the most interesting fields of application of this technique is the study of the carotid atherosclerotic plaque vascularization and its correlation with neurological symptoms (transient ischemic attack, minor stroke, and major stroke) and with the characteristics of the "vulnerable plaque" (surface ulceration, hypoechoic plaques, intraplaque hemorrhage, thinner fibrous cap, and carotid plaque neovascularization at histopathological analysis of the sample after surgical removal). The purpose of this review is to collect all the original studies available in literature (24 studies with 1356 patients enrolled) and to discuss the state of the art, limits, and future perspectives of CEUS analysis. The results of this work confirm the reliability of this imaging study for the detection of plaques with high risk of embolization; however, a shared, user-friendly protocol of imaging analysis is not available yet. The definition of this operative protocol becomes mandatory in order to compare results from different centers and to validate a cerebrovascular risk stratification of the carotid atherosclerotic lesions evaluated with CEUS.Entities:
Mesh:
Year: 2015 PMID: 26180793 PMCID: PMC4491377 DOI: 10.1155/2015/293163
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Figure 1(a) Histopathological preparation of a carotid atherosclerotic plaque colored with CD31 endothelial-specific stain (brown) showing the close correlation between plaque vascularization and the inflammatory response. (b) Histopathological preparation of a carotid atherosclerotic plaque colored with CD31 endothelial-specific stain (brown) showing larger microvessels (red arrows) and areas of plaque hemorrhage.
Summary of studies on carotid contrast-enhanced ultrasound (CEUS) for the detection of intraplaque neovascularization. The results of each study are expressed with the statistical significance (P value) of the correlation between the parameters.
| Author | Year | Number of patients | Symptomatic | Asymptomatic | Histology | Contrast agent | Ultrasound apparatus | Vascular probe | Mechanical index | CEUS analysis | Results | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Semiautomated analysis | Visual assessment | CEUS and histology | CEUS and carotid symptoms | CEUS and echogenicity | CEUS and other vulnerable characteristics | CEUS and gender | Software and visual assessment | ||||||||||
|
Li et al. [ | 2014 | 17 | 13 | 4 | 1 | SonoVue | Philips iU-22 ultrasound system | L 9-3 | 0,07 | 1 | 1 | 0,002 | 0 | 0 | 0 | 0 | 0 |
|
| |||||||||||||||||
| Hjelmgren et al. [ | 2014 | 13 | 7 | 6 | 0 | SonoVue | Siemens S2000 system | L 9-4 | 0,06 | 1 | 1 | 0 | 0,05 | 0,01 | 0 | 0 | 0,001 |
|
| |||||||||||||||||
| Kim et al. [ | 2014 | 89 | 0 | 89 | 1 | SonoVue | Acuson Sequoia 512 Siemens system | L 15-8 | 0,19 | 0 | 1 | 0,021 | 0 | 0 | 0 | 0 | 0 |
|
| |||||||||||||||||
| van den Oord et al. [ | 2014 | 143 | 0 | 143 | 0 | SonoVue | Philips iU-22 ultrasound system | L 9-3 | 0,06–0,08 | 1 | 1 | 0 | 0 | 0 | 0 | 0,03 | 0 |
|
| |||||||||||||||||
|
Müller et al. [ | 2014 | 33 | 17 | 16 | 1 | SonoVue | Antares Siemens system | nn | nn | 1 | 1 | 0,01 | Not significant | 0 | 0 | 0 | 0,02 |
|
| |||||||||||||||||
| Vavuranakis et al. [ | 2013 | 14 | 0 | 14 | 1 | SonoVue | Acuson Sequoia 512 Siemens system | L 15-8 | nn | 1 | 0 | 0,002 | 0 | 0 | 0 | 0 | 0 |
|
| |||||||||||||||||
| Ritter et al. [ | 2013 | 41 | 41 | 0 | 0 | SonoVue | GE Logiq 7 system | L 9-3 | nn | 0 | 1 | 0 | 0 | 0 | 0,02 | 0 | 0 |
|
| |||||||||||||||||
| Hjelmgren et al. [ | 2013 | 52 | 10 | 42 | 0 | SonoVue | Siemens S2000 system | L 9-4 | 0,06 | 1 | 0 | 0 | Not significant | 0,02 | 0 | 0 | 0 |
|
| |||||||||||||||||
| van den Oord et al. [ | 2013 | 69 | 0 | 69 | 0 | SonoVue | Philips iU-22 ultrasound system | L 9-3 | 0,06–0,08 | 1 | 1 | 0 | 0 | 0 | 0,05 | 0 | 0 |
|
| |||||||||||||||||
| Zhou et al. [ | 2013 | 46 | 24 | 22 | 0 | SonoVue | Acuson Sequoia 512 Siemens system | L 2 | 0,07 | 0 | 1 | 0 | Not significant | 0 | 0,05 | 0 | 0 |
|
| |||||||||||||||||
| Varetto et al. [ | 2012 | 51 | 12 | 39 | 1 | SonoVue | Esaote MyLab 25 Gold system | L 9-2 | nn | 1 | 0 | 0,001 | 0,01 | 0,02 | 0 | 0 | 0 |
|
| |||||||||||||||||
| Faggioli et al. [ | 2011 | 22 | 7 | 15 | 1 | SonoVue | Philips iU-22 ultrasound system | L 9-3 | 0.13 | 1 | 0 | 0,003 | 0,006 | 0 | 0 | 0 | 0 |
|
| |||||||||||||||||
| Hoogi et al. [ | 2011 | 27 | 8 | 19 | 1 | Definity | Philips iU-22 ultrasound system | L 8-4 | 1 | 0 | 0,01 | 0 | 0 | 0 | 0 | 0 | |
|
| |||||||||||||||||
| Shalhoub et al. [ | 2011 | 31 | 16 | 15 | 1 | SonoVue | Philips iU-22 ultrasound system | L 12-5 | 0,34 | 1 | 0 | 0,004 | 0 | 0 | 0 | 0 | 0 |
|
| |||||||||||||||||
| Owen et al. [ | 2010 | 37 | 16 | 21 | 0 | SonoVue | Philips iU-22 ultrasound system | L 12-5 | 0,34 | 1 | 0 | 0 | 0,005 | 0 | 0 | 0 | 0 |
|
| |||||||||||||||||
| Huang et al. [ | 2010 | 183 | 86 | 97 | 0 | SonoVue | Acuson Sequoia 512 Siemens system | L 15-8 | 0,35 | 1 | 1 | 0 | 0,001 | 0 | 0 | 0 | 0,001 |
|
| |||||||||||||||||
| Staub et al. | 2010 | 147 | 17 | 130 | 0 | Definity | ATL HDI 5000 Philips system | L 7-4 | 0,06–0,1 | 0 | 1 | 0 | 0 | 0 | 0,034 | 0 | 0 |
|
| |||||||||||||||||
| Giannoni et al. [ | 2009 | 77 | 64 | 9 | 1 | SonoVue | Acuson Sequoia 512 Siemens system | L 9-3 | 0,4–1,4 | 1 | 1 | >0,05 | 0,001 | 0,001 | 0 | 0 | 0 |
|
| |||||||||||||||||
| Magnoni et al. [ | 2009 | 25 | 0 | 25 | 0 | Optison | GE Vivid 7 system | L 7 | 0,08–01 | 0 | 1 | 0 | 0 | 0 | 0,001 | 0 | 0 |
|
| |||||||||||||||||
| Xiong et al. [ | 2009 | 104 | 35 | 69 | 0 | SonoVue | GE Logiq 9 system | L 9-3 | 0,13 | 1 | 0 | 0 | 0,001 | 0 | 0 | 0 | 0 |
|
| |||||||||||||||||
| Huang et al. [ | 2008 | 63 | 0 | 63 | 0 | SonoVue | Acuson Sequoia 512 Siemens system | L 15-8 | 0,35 | 1 | 0 | 0 | 0 | 0,01 | 0 | 0 | 0 |
|
| |||||||||||||||||
| Coli et al. [ | 2008 | 32 | 28 | 4 | 1 | Optison | GE Vivid 7 system | L 7 | 0,08–0,1 | 0 | 1 | 0,005 | 0,001 | 0 | 0 | 0 | |
|
| |||||||||||||||||
|
Vicenzini et al. [ | 2007 | 23 | 0 | 23 | 1 | SonoVue | Acuson Sequoia 512 Siemens system | L 6-15 | 0,4–1,4 | 0 | 1 | >0,05 | 0 | >0,05 | >0,05 | 0 | 0 |
|
| |||||||||||||||||
| Shah et al. [ | 2007 | 17 | 5 | 12 | 1 | Optison | ATL HDI 5000 Philips system | L 7-4 | 0,06–0,1 | 0 | 1 | 0,002 | 0 | 0 | 0 | 0 | 0 |
|
| |||||||||||||||||
| Total | 1356 | 406 | 946 | 12 | 16 | 15 | |||||||||||