Yunkou Wu1,2,3, Shanrong Zhang1, Todd C Soesbe1,2, Jing Yu4, Elena Vinogradov1,2, Robert E Lenkinski1,2, A Dean Sherry1,2,4. 1. Advanced Imaging Research Center, The University of Texas Southwestern Medical Center at Dallas, Texas, USA. 2. Department of Radiology, The University of Texas Southwestern Medical Center at Dallas, Texas, USA. 3. Department of Radiology, Howard University, Washington DC, USA. 4. Department of Chemistry, The University of Texas at Dallas, Richardson, Texas, USA.
Abstract
PURPOSE: This study explored the feasibility of using a pH responsive paramagnetic chemical exchange saturation transfer (paraCEST) agent to image the pH gradient in kidneys of healthy mice. METHODS: CEST signals were acquired on an Agilent 9.4 Tesla small animal MRI system using a steady-state gradient echo pulse sequence after a bolus injection of agent. The magnetic field inhomogeneity across each kidney was corrected using the WASSR method and pH maps were calculated by measuring the frequency of water exchange signal arising from the agent. RESULTS: Dynamic CEST studies demonstrated that the agent was readily detectable in kidneys only between 4 to 12 min postinjection. The CEST images showed a higher signal intensity in the pelvis and calyx regions and lower signal intensity in the medulla and cortex regions. The pH maps reflected tissue pH values spanning from 6.0 to 7.5 in kidneys of healthy mice. CONCLUSION: This study demonstrated that pH maps of the kidney can be imaged in vivo by measuring the pH-dependent chemical shift of a single water exchange CEST peak without prior knowledge of the agent concentration in vivo. The results demonstrate the potential of using a simple frequency-dependent paraCEST agent for mapping tissue pH in vivo. Magn Reson Med 75:2432-2441, 2016.
PURPOSE: This study explored the feasibility of using a pH responsive paramagnetic chemical exchange saturation transfer (paraCEST) agent to image the pH gradient in kidneys of healthy mice. METHODS: CEST signals were acquired on an Agilent 9.4 Tesla small animal MRI system using a steady-state gradient echo pulse sequence after a bolus injection of agent. The magnetic field inhomogeneity across each kidney was corrected using the WASSR method and pH maps were calculated by measuring the frequency of water exchange signal arising from the agent. RESULTS: Dynamic CEST studies demonstrated that the agent was readily detectable in kidneys only between 4 to 12 min postinjection. The CEST images showed a higher signal intensity in the pelvis and calyx regions and lower signal intensity in the medulla and cortex regions. The pH maps reflected tissue pH values spanning from 6.0 to 7.5 in kidneys of healthy mice. CONCLUSION: This study demonstrated that pH maps of the kidney can be imaged in vivo by measuring the pH-dependent chemical shift of a single water exchange CEST peak without prior knowledge of the agent concentration in vivo. The results demonstrate the potential of using a simple frequency-dependent paraCEST agent for mapping tissue pH in vivo. Magn Reson Med 75:2432-2441, 2016.
Authors: Vipul R Sheth; Yuguo Li; Liu Qi Chen; Christine M Howison; Chris A Flask; Mark D Pagel Journal: Magn Reson Med Date: 2011-10-25 Impact factor: 4.668
Authors: Liu Qi Chen; Christine M Howison; Justin J Jeffery; Ian F Robey; Phillip H Kuo; Mark D Pagel Journal: Magn Reson Med Date: 2013-11-26 Impact factor: 4.668
Authors: D Delli Castelli; Giuseppe Ferrauto; Juan Carlos Cutrin; Enzo Terreno; Silvio Aime Journal: Magn Reson Med Date: 2013-03-25 Impact factor: 4.668
Authors: Ferdia A Gallagher; Mikko I Kettunen; Sam E Day; De-En Hu; Jan Henrik Ardenkjaer-Larsen; René in 't Zandt; Pernille R Jensen; Magnus Karlsson; Klaes Golman; Mathilde H Lerche; Kevin M Brindle Journal: Nature Date: 2008-05-28 Impact factor: 49.962
Authors: Or Perlman; Kai Herz; Moritz Zaiss; Ouri Cohen; Matthew S Rosen; Christian T Farrar Journal: Magn Reson Med Date: 2019-08-09 Impact factor: 4.668
Authors: S James Ratnakar; Sara Chirayil; Alexander M Funk; Shanrong Zhang; João F Queiró; Carlos F G C Geraldes; Zoltan Kovacs; A Dean Sherry Journal: Angew Chem Int Ed Engl Date: 2020-10-06 Impact factor: 15.336
Authors: Cemile Kumas; W Shirangi Fernando; Piyu Zhao; Martín Regueiro-Figueroa; Garry E Kiefer; André F Martins; Carlos Platas-Iglesias; A Dean Sherry Journal: Inorg Chem Date: 2016-09-07 Impact factor: 5.165
Authors: Edward A Randtke; Jeffry C Granados; Christine M Howison; Mark D Pagel; Julio Cárdenas-Rodríguez Journal: Magn Reson Med Date: 2016-07-28 Impact factor: 4.668
Authors: Shaowei Bo; Farzad Sedaghat; KowsalyaDevi Pavuluri; Steven P Rowe; Andrew Cohen; Max Kates; Michael T McMahon Journal: Tomography Date: 2021-03-02