| Literature DB >> 26173484 |
Ivan E Vickers1, Kevin M Harvey2, Michelle G Brown3, Kereann Nelson4, Marion Bullock DuCasse5, John F Lindo6.
Abstract
BACKGROUND: Dengue is an important mosquito-borne viral infection that affects millions of persons worldwide. Early diagnosis is necessary to effect appropriate management and decrease mortality. Immunochromatographic tests are advantageous in producing dengue test results within 30 min but these results should be sensitive and specific. In this study we evaluated the diagnostic performance of the SD BIOLINE Dengue DUO® rapid immunochromatographic test kit. A panel of 309 dengue and 30 non-dengue single serum samples characterized by using reference enzyme-linked immunosorbent assays (ELISAs) was used. These samples were received in the virology laboratory for routine testing during a dengue type 1 outbreak between October to December, 2012.Entities:
Mesh:
Substances:
Year: 2015 PMID: 26173484 PMCID: PMC4502463 DOI: 10.1186/s12929-015-0164-9
Source DB: PubMed Journal: J Biomed Sci ISSN: 1021-7770 Impact factor: 8.410
Overall diagnostic performance of the SDB DD ICT against reference ELISAs
| Dengue Parameter | No. of dengue ELISA pos/neg | No. of SDB DD ICT pos/neg | Sensitivity % (95 % CI) | Specificity % (95 % CI) | PPV % (95 % CI) | NPV % (95 % CI) |
|---|---|---|---|---|---|---|
| IgM | 145/194 | 71/187 | 49.3 (41.3-57.4) | 95.9 (92.1-97.9) | 89.9 (81.3-94.8) | 71.9 (66.2-77.0) |
| NS1 | 90/249 | 81/247 | 90.0 (82.1-94.7) | 99.2 (97.1-99.8) | 97.6 (91.6-99.3) | 96.5 (93.5-98.1) |
| IgG | 256/83 | 100/83 | 39.1 (33.3-45.2) | 100 (95.6-100) | 100 (96.3-100) | 34.7 (29.0-41.0) |
| IgM/NS1 | 121/157 | 117/157 | 97.5 (92.9-99.2) | 100 (97.6-100) | 100 (96.8-100) | 98.1 (94.6-99.4) |
| IgM/ NS1/ IgG | 181/29 | 179/29 | 98.9 (96.0-99.7) | 100 (88.3-100) | 100 (97.9-100) | 93.6 (79.3-98.2) |
95 % CI is shown in parenthesis. pos = positive; neg = negative; SDB DD = SD BIOLINE Dengue DUO®; ICT = Immunochromatographic test
Fig. 1Sensitivity of SDB DD ICT according to dengue immune status. Data represent sensitivity (%) and error bars represent 95 % CI. *indicates significance at p < 0.001, when comparing primary and secondary dengue samples
Fig. 2Sensitivity of SDB DD ICT according to sample collection phase. Data represent sensitivity (%) and error bars represent 95 % CI. *indicates significance at the p < 0.001 level when comparing acute and convalescent dengue samples
Sensitivity of the SDB DD NS1 parameter according to IgM/IgG antibody profile
| Dengue antibody profile | Sensitivity | N | P value |
|---|---|---|---|
| IgM−/IgG− | 94.4(74.2- 99.0) | 18 | 0.899a |
| IgM+/IgG− | 91.2(77.0-97.0) | 34 | |
| IgM−/IgG+ | 100(75.8-100) | 12 | 0.265b |
| IgM+/IgG+ | 80.8(62.1-91.5) | 26 |
95 % CI is shown in parenthesis; − = negative; + = positive; a = comparison between IgM−/IgG− and IgM+/IgG− ; b = comparison between IgM−/IgG+ and IgM+/IgG+