Literature DB >> 26162637

[Catheter-based closure of paravalvular leaks: "Plug the hole"].

Nicolas Werner1, C Kilkowski, R Zahn.   

Abstract

Paravalvular leak (PVL) is a relatively rare, but serious complication occurring in up to 10% of patients after prosthetic aortic valve replacement and in up to 17% of patients after prosthetic mitral valve replacement. Up to 5% of patients will present with symptoms of congestive heart failure or mechanical haemolytic anaemia due to PVL and need further surgical or interventional treatment. Surgical repair is often technically challenging and carries a high mortality and morbidity risk. Catheter-based closure of PVL has emerged as an alternative approach especially for patients with relevant comorbidities at high surgical risk. Interventional closure of PVL is a complex procedure, which needs to be performed by an experienced team of interventional cardiologist, echocardiographer and anesthesiologist. To date available clinical results are promising showing low complication rates and high technical or clinical success rates of catheter-based closure of PVL (60-90%). Compared to surgical closure of PVL lower mortality rates (30-days mortality rate: 4,6%) have been documented in patients treated by catheter-based closure of PVL in clinical practice. Therefore interventional closure seems to be a promising option, which need to be discussed with every symptomatic patient suffering from PVL prior to therapeutical decision making. To date only sparse clinical data is available regarding indication and clinical outcome of patients undergoing catheter-based PVL in clinical practice. Therefore interventional closure of PVL should be limited to experienced interventional cardiologist at present. All patients treated should further be enrolled into a clinical registry to evaluate the safety and efficacy of catheter-based closure of PVL in clinical practice.

Entities:  

Mesh:

Year:  2015        PMID: 26162637     DOI: 10.1007/s00059-015-4329-9

Source DB:  PubMed          Journal:  Herz        ISSN: 0340-9937            Impact factor:   1.443


  23 in total

1.  Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: final report of the Veterans Affairs randomized trial.

Authors:  K Hammermeister; G K Sethi; W G Henderson; F L Grover; C Oprian; S H Rahimtoola
Journal:  J Am Coll Cardiol       Date:  2000-10       Impact factor: 24.094

2.  Long-term follow-up of percutaneous repair of paravalvular prosthetic regurgitation.

Authors:  Paul Sorajja; Allison K Cabalka; Donald J Hagler; Charanjit S Rihal
Journal:  J Am Coll Cardiol       Date:  2011-11-15       Impact factor: 24.094

3.  Mitral valve periprosthetic leakage: Anatomical observations in 135 patients from a multicentre study.

Authors:  Giuseppe De Cicco; Claudio Russo; Antonella Moreo; Cesare Beghi; Carlo Fucci; Piersilvio Gerometta; Roberto Lorusso
Journal:  Eur J Cardiothorac Surg       Date:  2006-11-01       Impact factor: 4.191

4.  Closure of perivalvular leaks using an Amplatzer occluder.

Authors:  Juan H Alonso-Briales; Antonio J Muñoz-García; Manuel F Jiménez-Navarro; Antonio J Domínguez-Franco; José M Melero-Tejedor; Isabel Rodríguez-Bailón; José M Hernández-García; Eduardo de Teresa-Galván
Journal:  Rev Esp Cardiol       Date:  2009-04       Impact factor: 4.753

5.  Principles of percutaneous paravalvular leak closure.

Authors:  Charanjit S Rihal; Paul Sorajja; Jeffrey D Booker; Donald J Hagler; Allison K Cabalka
Journal:  JACC Cardiovasc Interv       Date:  2012-02       Impact factor: 11.195

6.  Natural history of early aortic paraprosthetic regurgitation: a five-year follow-up.

Authors:  L S Rallidis; I E Moyssakis; I Ikonomidis; P Nihoyannopoulos
Journal:  Am Heart J       Date:  1999-08       Impact factor: 4.749

7.  Transcatheter closure of paravalvular defects using a purpose-specific occluder.

Authors:  Fabian Nietlispach; Mark Johnson; Robert R Moss; Namal Wijesinghe; Ronen Gurvitch; Edgar L W Tay; Christopher Thompson; John G Webb
Journal:  JACC Cardiovasc Interv       Date:  2010-07       Impact factor: 11.195

8.  Percutaneous repair of paravalvular prosthetic regurgitation: acute and 30-day outcomes in 115 patients.

Authors:  Paul Sorajja; Allison K Cabalka; Donald J Hagler; Charanjit S Rihal
Journal:  Circ Cardiovasc Interv       Date:  2011-07-26       Impact factor: 6.546

9.  Transcatheter umbrella closure of valvular and paravalvular leaks.

Authors:  M Hourihan; S B Perry; V S Mandell; J F Keane; J J Rome; J A Bittl; J E Lock
Journal:  J Am Coll Cardiol       Date:  1992-11-15       Impact factor: 24.094

Review 10.  Review of surgical prosthetic paravalvular leaks: diagnosis and catheter-based closure.

Authors:  Chad Kliger; Rocio Eiros; Guillermo Isasti; Bryce Einhorn; Vladimir Jelnin; Howard Cohen; Itzhak Kronzon; Gila Perk; Gregory P Fontana; Carlos E Ruiz
Journal:  Eur Heart J       Date:  2012-11-01       Impact factor: 29.983

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.