Literature DB >> 26162254

Comparison of Canal Transportation, Centering Ratio by Cone-beam Computed Tomography after Preparation with Different File Systems.

Emel Uzunoglu1, Sevinc Aktemur Turker2.   

Abstract

AIM: One Shape Apical 1 (OSA 1) is a new file for preparing the apical aspect of the root canal after One Shape (OS, Micro Mega, Besançon, France). This study compared apical transportation and centering ratios in curved root canals, which were instrumented with ProTaper Next (PTN, Dentsply Tulsa Dental Specialties, Tulsa, OK) up to size X3 and with OS up to OSA 1.
MATERIALS AND METHODS: Forty-eight mesial canals of mandibular molars were assigned into two groups (n = 24) with respect to canal length and curvature. Root canals were accessed conventionally and preperation was completed with PTN files up to X3 or with OS up to OSA 1 according to the manufacturer's protocols. Apical transportation was assessed pre- and postinstrumentation using cone-beam computed tomographic (CBCT) scans of 1, 2, 3, 4, and 5 mm sections. A Friedman test was performed to assess the significance between file systems.
RESULTS: No significant difference was found between the file systems regarding apical transportation and centering ratio values (p > 0.05). Transportation in the mesial direction was greater than the distal transportation for both file systems.
CONCLUSION: Considering apical transportation and centering ratio in curved canals, two systems provided similar results. CLINICAL SIGNIFICANCE: Preparation up to One Shape Apical 1 or ProTaper Next X3 was shown similar results regarding apical transportation and centering ratio. Both systems were safe to use in curved molar root canals.

Entities:  

Keywords:  Cone-beam computed tomography; Root canal preparation; Transportation.

Mesh:

Year:  2015        PMID: 26162254     DOI: 10.5005/jp-journals-10024-1690

Source DB:  PubMed          Journal:  J Contemp Dent Pract        ISSN: 1526-3711


  2 in total

1.  Comparative Assessment of Canal Transportation and Centering Ability of Reciproc and One Shape File Systems Using CBCT-An In Vitro Study.

Authors:  Anika Mittal; Shifali Dadu; Neetu Sharma Singh; Sarita Singh; Bhupesh Gupta; Anju Abraham; Bidya Yendrembam; Shilpa Kumari
Journal:  J Clin Diagn Res       Date:  2017-04-01

2.  Micro-computed tomographic assessment of the shaping ability of the One Curve, One Shape, and ProTaper Next nickel-titanium rotary systems.

Authors:  Pelin Tufenkci; Kaan Orhan; Berkan Celikten; Burak Bilecenoglu; Gurkan Gur; Semra Sevimay
Journal:  Restor Dent Endod       Date:  2020-05-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.