Literature DB >> 26162025

Do Chondral Lesions of the Knee Correlate with Bone Tracer Uptake by Using SPECT/CT?

Milos Dordevic1, Michael T Hirschmann1, Jan Rechsteiner1, Anna Falkowski1, Enrique Testa1, Anna Hirschmann1.   

Abstract

PURPOSE: To evaluate the correlation of bone tracer uptake as determined with single photon emission computed tomography (SPECT)/computed tomography (CT) and the size and severity of chondral lesions detected with magnetic resonance (MR) imaging of the knee.
MATERIALS AND METHODS: MR imaging and SPECT/CT images of 63 knee joints in 63 patients (mean age ± standard deviation, 49.2 years ± 12.7) with chondral or osteochondral lesions were prospectively collected and retrospectively analyzed after approval by the ethics committee. Chondral lesions were graded on MR images by using a modified Noyes grading scale (grade 0, intact; grade 1, fibrillations; grade 2, <50% defect; grade 3, >50% defect; and grade 4, grade three plus subchondral changes) and measured in two dimensions. Technetium 99m hydroxymethane diphosphonate SPECT/CT bone tracer uptake was volumetrically quantified by using validated software. Maximum values of each subchondral area (patellofemoral or medial and lateral femorotibial) were quantified, and a ratio was calculated in relation to a reference region in the femoral shaft, which represented the bone tracer uptake background activity. Grades and sizes of chondral lesions and bone tracer uptake were correlated by using an independent t test and analysis of variance (P < .05).
RESULTS: Bone tracer uptake was low (mean relative uptake, 1.64 ± 0.95) in knees without any present chondral lesion. In knees with grade 3 and 4 chondral lesions, the relative ratio was significantly higher (3.62 ± 2.18, P = .002) than in knees with grade 1 and 2 lesions (2.95 ± 2.07). The larger the diameter of the chondral lesion, the higher the bone tracer uptake. Higher grades of chondral lesions (grades 3 and 4) larger than 4 cm(2) (4.96 ± 2.43) showed a significantly higher bone tracer uptake than smaller lesions (<1 cm(2), 2.72 ± 1.43 [P = .011]; and 1-4 cm(2), 3.28 ± 2.15 [P = .004]).
CONCLUSION: SPECT/CT findings significantly correlate with the degree and size of chondral lesions on MR images. Grade 3 and 4 chondral lesions of the knee, as well as larger lesions, correlate with a high bone tracer uptake. © RSNA, 2015.

Entities:  

Mesh:

Year:  2015        PMID: 26162025     DOI: 10.1148/radiol.2015141714

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  Good clinical results but moderate osseointegration and defect filling of a cell-free multi-layered nano-composite scaffold for treatment of osteochondral lesions of the knee.

Authors:  Dominic T Mathis; Raphael Kaelin; Helmut Rasch; Markus P Arnold; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-07-15       Impact factor: 4.342

2.  Bloodpool SPECT as part of bone SPECT/CT in painful total knee arthroplasty (TKA): validation and potential biomarker of prosthesis biomechanics.

Authors:  Jolien Verschueren; Adrien Albert; Laurens Carp; Sarah Ceyssens; Ivan Huyghe; Sigrid Stroobants; Frédéric Paycha; Gopinath Gnanasegaran; Tim Van den Wyngaert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-01-02       Impact factor: 9.236

Review 3.  Imaging of osteoarthritis-recent research developments and future perspective.

Authors:  Daichi Hayashi; Frank W Roemer; Ali Guermazi
Journal:  Br J Radiol       Date:  2018-01-19       Impact factor: 3.039

4.  Patterns of bone tracer uptake on SPECT-CT in symptomatic and asymptomatic patients with primary total hip arthroplasty.

Authors:  Thierry Schweizer; Filippo-Franco Schiapparelli; Niccolo Rotigliano; Helmut Rasch; Felix Amsler; Michael T Hirschmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-09-19       Impact factor: 9.236

Review 5.  SPECT/CT arthrography.

Authors:  Ujwal Bhure; Justus E Roos; Maria Del Sol Pérez Lago; Isabelle Steurer; Hannes Grünig; Urs Hug; Klaus Strobel
Journal:  Br J Radiol       Date:  2017-11-16       Impact factor: 3.039

6.  Meniscal pathologies on MRI correlate with increased bone tracer uptake in SPECT/CT.

Authors:  Jan Rechsteiner; Michael T Hirschmann; Milos Dordevic; Anna L Falkowski; Enrique A Testa; Felix Amsler; Anna Hirschmann
Journal:  Eur Radiol       Date:  2018-05-22       Impact factor: 5.315

7.  Increased bone tracer uptake in symptomatic patients with ACL graft insufficiency: a correlation of MRI and SPECT/CT findings.

Authors:  Dominic T Mathis; Anna Hirschmann; Anna L Falkowski; Tommi Kiekara; Felix Amsler; Helmut Rasch; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-05-27       Impact factor: 4.342

8.  Alignment changes after open-wedge high tibial osteotomy result in offloading in the patellofemoral joint: a SPECT/CT analysis.

Authors:  Jae Ang Sim; Young Gon Na; Beom Koo Lee; Byung Hoon Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-06-23       Impact factor: 4.114

9.  Evaluation of patients with painful total hip arthroplasty using combined single photon emission tomography and conventional computerized tomography (SPECT/CT) - a comparison of semi-quantitative versus 3D volumetric quantitative measurements.

Authors:  Emilienne Barthassat; Faik Afifi; Praveen Konala; Helmut Rasch; Michael T Hirschmann
Journal:  BMC Med Imaging       Date:  2017-05-08       Impact factor: 1.930

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.