Dominic T Mathis1, Raphael Kaelin2, Helmut Rasch3,4, Markus P Arnold2,4, Michael T Hirschmann5,6. 1. Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), 4101, Bruderholz, Switzerland. 2. LEONARDO, Hirslanden Klinik Birshof, 4142, Münchenstein, Switzerland. 3. Institute of Radiology and Nuclear Medicine, Kantonsspital Baselland, 4101, Bruderholz, Switzerland. 4. University of Basel, Basel, Switzerland. 5. Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), 4101, Bruderholz, Switzerland. michael.hirschmann@ksbl.ch. 6. University of Basel, Basel, Switzerland. michael.hirschmann@ksbl.ch.
Abstract
PURPOSE: The aim of this retrospective study was to evaluate the clinical and radiological results of a nano-composite multi-layered three-dimensional biomaterial scaffold for treatment of osteochondral lesions (OCL) of the knee. It was a particular radiological interest to analyse the osseointegration, filling of the defects and the bone tracer uptake (BTU), and it was hypothesised that this scaffold, which was created to mimic the entire osteo-cartilaginous unit, is integrated within the bone 12 months postoperatively and comes along with improved patients symptoms and function. METHODS: Fourteen patients (male:female = 11:3, mean age ± SD 33.1 ± 10.7 years) treated for OCL (size 1.0-3.5 cm2) were clinically and radiologically evaluated at 1 year postoperatively. The data were prospectively collected including SPECT/CT, Tegner and Lysholm scores. BTU was anatomically localised and volumetrically quantified in SPECT/CT. Defect filling was analysed in CT. Spearman's rho and Wilcoxon test were used for correlation of BTU in SPECT/CT and clinical scores (p < 0.05). RESULTS: A significant improvement in Lysholm knee score (p < 0.001) and slight deterioration in Tegner score were found (p < 0.01). A complete filling of the defect was shown in 14%, a partial filling in 14% and only minor filling was seen in 72%. A significant correlation (p < 0.001) was found between location of osteochondral lesions and increased BTU. At the lesion sites pre- and postoperative BTU was markedly increased and did not show any decrease at 12-month follow-up. Median Tegner and mean Lysholm scores did not correlate with BTU at any time. CONCLUSIONS: Treatment of OCL in the knee joint with a nano-composite multi-layered three-dimensional biomaterial scaffold resulted in a significant clinical improvement at 1-year follow-up. However, osseointegration was still ongoing at 12-month follow-up. LEVEL OF EVIDENCE: Case series, Level IV.
PURPOSE: The aim of this retrospective study was to evaluate the clinical and radiological results of a nano-composite multi-layered three-dimensional biomaterial scaffold for treatment of osteochondral lesions (OCL) of the knee. It was a particular radiological interest to analyse the osseointegration, filling of the defects and the bone tracer uptake (BTU), and it was hypothesised that this scaffold, which was created to mimic the entire osteo-cartilaginous unit, is integrated within the bone 12 months postoperatively and comes along with improved patients symptoms and function. METHODS: Fourteen patients (male:female = 11:3, mean age ± SD 33.1 ± 10.7 years) treated for OCL (size 1.0-3.5 cm2) were clinically and radiologically evaluated at 1 year postoperatively. The data were prospectively collected including SPECT/CT, Tegner and Lysholm scores. BTU was anatomically localised and volumetrically quantified in SPECT/CT. Defect filling was analysed in CT. Spearman's rho and Wilcoxon test were used for correlation of BTU in SPECT/CT and clinical scores (p < 0.05). RESULTS: A significant improvement in Lysholm knee score (p < 0.001) and slight deterioration in Tegner score were found (p < 0.01). A complete filling of the defect was shown in 14%, a partial filling in 14% and only minor filling was seen in 72%. A significant correlation (p < 0.001) was found between location of osteochondral lesions and increased BTU. At the lesion sites pre- and postoperative BTU was markedly increased and did not show any decrease at 12-month follow-up. Median Tegner and mean Lysholm scores did not correlate with BTU at any time. CONCLUSIONS: Treatment of OCL in the knee joint with a nano-composite multi-layered three-dimensional biomaterial scaffold resulted in a significant clinical improvement at 1-year follow-up. However, osseointegration was still ongoing at 12-month follow-up. LEVEL OF EVIDENCE: Case series, Level IV.
Authors: Michael Tobias Hirschmann; Kinner Davda; Helmut Rasch; Markus P Arnold; Niklaus F Friederich Journal: Sports Med Arthrosc Rev Date: 2011-06 Impact factor: 1.985
Authors: Stephan N Schön; Faik K Afifi; Helmut Rasch; Felix Amsler; Niklaus F Friederich; Markus P Arnold; Michael T Hirschmann Journal: Knee Surg Sports Traumatol Arthrosc Date: 2013-10-11 Impact factor: 4.342
Authors: E Kon; M Delcogliano; G Filardo; D Pressato; M Busacca; B Grigolo; G Desando; M Marcacci Journal: Injury Date: 2009-12-24 Impact factor: 2.586
Authors: Markus M Schreiner; Marcus Raudner; Stefan Marlovits; Klaus Bohndorf; Michael Weber; Martin Zalaudek; Sebastian Röhrich; Pavol Szomolanyi; Giuseppe Filardo; Reinhard Windhager; Siegfried Trattnig Journal: Cartilage Date: 2019-08-17 Impact factor: 4.634