Literature DB >> 26158116

Automated working distance adjustment enables optical coherence tomography of the human larynx in awake patients.

Sabine Donner1, Sebastian Bleeker1, Tammo Ripken1, Martin Ptok2, Michael Jungheim2, Alexander Krueger1.   

Abstract

Optical coherence tomography (OCT) provides structural information of laryngeal tissue which is comparable to histopathological analysis of biopsies taken under general anesthesia. In awake patients, movements impede clinically useful OCT acquisition. Therefore, an automatic compensation of movements was implemented into a swept source OCT-laryngoscope. Video and OCT beam path were combined in one tube of 10-mm diameter. Segmented OCT images served as distance sensor and a feedback control adjusted the working distance between 33 and 70 mm by synchronously translating the reference mirror and focusing lens. With this motion compensation, the tissue was properly visible in up to 88% of the acquisition time. During quiet respiration, OCT contrasted epithelium and lamina propria. Mean epithelial thickness was measured to be 109 and [Formula: see text] in female and male, respectively. Furthermore, OCT of mucosal wave movements during phonation enabled estimation of the oscillation frequency and amplitude. Regarding clinical issues, the OCT-laryngoscope with automated working distance adjustment may support the estimation of the depth extent of epithelial lesions and contribute to establish an indication for a biopsy. Moreover, OCT of the vibrating vocal folds provides functional information, possibly giving further insight into mucosal behavior during the vibratory cycle.

Entities:  

Keywords:  autofocus; laryngoscopy; motion compensation; optical coherence tomography

Year:  2015        PMID: 26158116      PMCID: PMC4481024          DOI: 10.1117/1.JMI.2.2.026003

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  16 in total

1.  Imaging the human vocal folds in vivo with optical coherence tomography: a preliminary experience.

Authors:  Adam M Klein; Mark C Pierce; Steven M Zeitels; R Rox Anderson; James B Kobler; Milen Shishkov; Johannes F de Boer
Journal:  Ann Otol Rhinol Laryngol       Date:  2006-04       Impact factor: 1.547

2.  Motion artifacts in optical coherence tomography with frequency-domain ranging.

Authors:  S H Yun; G Tearney; J de Boer; B Bouma
Journal:  Opt Express       Date:  2004-06-28       Impact factor: 3.894

3.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

4.  Active tremor cancellation by a "smart" handheld vitreoretinal microsurgical tool using swept source optical coherence tomography.

Authors:  Cheol Song; Peter L Gehlbach; Jin U Kang
Journal:  Opt Express       Date:  2012-10-08       Impact factor: 3.894

5.  Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror.

Authors:  Chen D Lu; Martin F Kraus; Benjamin Potsaid; Jonathan J Liu; Woojhon Choi; Vijaysekhar Jayaraman; Alex E Cable; Joachim Hornegger; Jay S Duker; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2013-12-20       Impact factor: 3.732

6.  In vivo optical coherence tomography of the human larynx: normative and benign pathology in 82 patients.

Authors:  Brian J F Wong; Ryan P Jackson; Shuguang Guo; James M Ridgway; Usama Mahmood; Jianping Su; Terry Y Shibuya; Roger L Crumley; Mai Gu; William B Armstrong; Zhongping Chen
Journal:  Laryngoscope       Date:  2005-11       Impact factor: 3.325

7.  Optical coherence tomography allows for the reliable identification of laryngeal epithelial dysplasia and for precise biopsy: a clinicopathological study of 61 patients undergoing microlaryngoscopy.

Authors:  Tino Just; Eva Lankenau; Friedrich Prall; Gereon Hüttmann; Hans Wilhelm Pau; Konrad Sommer
Journal:  Laryngoscope       Date:  2010-10       Impact factor: 3.325

8.  Office-based dynamic imaging of vocal cords in awake patients with swept-source optical coherence tomography.

Authors:  Lingfeng Yu; Gangjun Liu; Marc Rubinstein; Arya Saidi; Brian J F Wong; Zhongping Chen
Journal:  J Biomed Opt       Date:  2009 Nov-Dec       Impact factor: 3.170

9.  Clinical value of optical coherence tomography in laryngology.

Authors:  Marcel Kraft; Hiltrud Glanz; Susanne von Gerlach; Henning Wisweh; Holger Lubatschowski; Christoph Arens
Journal:  Head Neck       Date:  2008-12       Impact factor: 3.147

10.  Laryngeal epithelial thickness: a comparison between optical coherence tomography and histology.

Authors:  M L Kaiser; M Rubinstein; D E Vokes; J M Ridgway; S Guo; M Gu; R L Crumley; W B Armstrong; Z Chen; B J F Wong
Journal:  Clin Otolaryngol       Date:  2009-10       Impact factor: 2.597

View more
  6 in total

1.  Euclidean distances of laryngopharyngeal structures obtained from CT data for preclinical development of laryngoscopic devices.

Authors:  Daniela Diers; Jacob Friedemann Fast; Friedrich Götz; Lüder Alexander Kahrs; Simone Miller; Michael Jungheim; Martin Ptok
Journal:  Surg Radiol Anat       Date:  2019-12-19       Impact factor: 1.246

2.  Surface kinematic and depth-resolved analysis of human vocal folds in vivo during phonation using optical coherence tomography.

Authors:  Giriraj K Sharma; Lily Y Chen; Lidek Chou; Christopher Badger; Ellen Hong; Swathi Rangarajan; Theodore H Chang; William B Armstrong; Sunil P Verma; Zhongping Chen; Ram Ramalingam; Brian J-F Wong
Journal:  J Biomed Opt       Date:  2021-08       Impact factor: 3.170

Review 3.  [Optical coherence tomography for early diagnosis of epithelial dysplasia and microinvasive carcinoma of the upper aerodigestive tract].

Authors:  V Volgger; C Arens; M Kraft; A S Englhard; C S Betz
Journal:  HNO       Date:  2016-01       Impact factor: 1.284

Review 4.  [Optical diagnostic methods for early tumour diagnosis in the upper aerodigestive tract: Quo vadis?].

Authors:  C S Betz; M Kraft; C Arens; M Schuster; C Pfeffer; A Rühm; H Stepp; A Englhard; V Volgger
Journal:  HNO       Date:  2016-01       Impact factor: 1.284

5.  In vivo cross-sectional imaging of the phonating larynx using long-range Doppler optical coherence tomography.

Authors:  Carolyn A Coughlan; Li-Dek Chou; Joseph C Jing; Jason J Chen; Swathi Rangarajan; Theodore H Chang; Giriraj K Sharma; Kyoungrai Cho; Donghoon Lee; Julie A Goddard; Zhongping Chen; Brian J F Wong
Journal:  Sci Rep       Date:  2016-03-10       Impact factor: 4.379

6.  Clinical translation of handheld optical coherence tomography: practical considerations and recent advancements.

Authors:  Guillermo L Monroy; Jungeun Won; Darold R Spillman; Roshan Dsouza; Stephen A Boppart
Journal:  J Biomed Opt       Date:  2017-12       Impact factor: 3.170

  6 in total