| Literature DB >> 26157222 |
Sin Ho Chung1, Young Youl You2.
Abstract
[Purpose] The purpose of this study was to assess intra-rater and inter-rater procedural reliability of ultrasound imaging measurements of transversus abdominis thickness. [Subjects] Thirty therapists who attended the B Hospital in Hwaseong participated in the study. [Methods] Two examiners assessed transverse abdominis thickness at rest and during contraction. Intra-class correlation coefficient with 95% confidence interval and, standard error of measurement were calculated.Entities:
Keywords: Reliability; Transversus abdominis; Ultrasound imaging
Year: 2015 PMID: 26157222 PMCID: PMC4483400 DOI: 10.1589/jpts.27.1373
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
Intra-rater reliability data of ultrasound imaging for measurement of TrA thickness
| Mean±SD (cm) | ICC(3,2) (95% CI) | SEM | |
|---|---|---|---|
| Within-day reliability | |||
| Rest | 0.32±0.02 | 0.65 (0.26–0.83) | 0.015 |
| Contraction | 0.41±0.04 | 0.86 (0.70–0.93) | 0.015 |
| Between-day reliability | |||
| Rest | 0.32±0.02 | 0.77 (0.52–0.89) | 0.013 |
| Contraction | 0.40±0.03 | 0.85 (0.69–0.93) | 0.015 |
TrA: transversus abdominis; SD: standard deviation; ICC: intra-class correlation coefficients; 95% CI: 95% confidence interval; SEM: standard error of measurement
Inter-rater reliability data of ultrasound imaging for measurement of TrA thickness
| Mean±SD (cm) | ICC(3,2) (95% CI) | SEM | |
|---|---|---|---|
| Within-day reliability | |||
| Rest | 0.32±0.02 | 0.72 (0.41–0.87) | 0.011 |
| Contraction | 0.41±0.04 | 0.86 (0.71–0.94) | 0.008 |
| Between-day reliability | |||
| Rest | 0.33±0.02 | 0.83 (0.63–0.92) | 0.014 |
| Contraction | 0.41±0.04 | 0.82 (0.62–0.91) | 0.015 |
TrA: transversus abdominis; SD: standard deviation; ICC: intra-class correlation coefficients; 95% CI: 95% confidence interval; SEM: standard error of measurement