Literature DB >> 24361824

Reliability of the ultrasound measurements of abdominal muscles activity when activated with and without pelvic floor muscles contraction.

Nahid Tahan1, Omid Rasouli2, Amir Massoud Arab3, Khosro Khademi1, Elham Neisani Samani4.   

Abstract

BACKGROUND: Synergistic co-activation of the abdominal and pelvic floor muscles (PFM) has been shown in literature. Some studies have assessed the reliability of ultrasound measures of the abdominal muscles.
OBJECTIVE: The aim of this study was to determine the reliability of ultrasound measurements of transverses abdominis (TrA) and obliquus internus (OI) muscles during different conditions (PFM contraction, abdominal hollowing manoeuvre (AHM) with and without PFM contraction) in participants with and without chronic low back pain (LBP).
METHODS: 21 participants (9 with LBP, 12 healthy) participated in the study. The reliability of thickness measurements at rest and during each condition and thickness changes and percentage of this changes at different conditions were assessed.
RESULTS: The results showed high reliability of the thickness measurement at rest and during each condition of TrA and OI muscles, moderate to substantial reliability for the thickness change and percentage of thickness change of TrA, and fair to moderate reliability of the thickness change and percentage of thickness change of OI in both groups.
CONCLUSIONS: Ultrasound imaging can be used as a reliable method for assessment of abdominal muscle activity with and without PFM contraction.

Entities:  

Keywords:  Low back pain; abdominal muscles; pelvic floor muscles; reliability

Mesh:

Year:  2014        PMID: 24361824     DOI: 10.3233/BMR-130453

Source DB:  PubMed          Journal:  J Back Musculoskelet Rehabil        ISSN: 1053-8127            Impact factor:   1.398


  3 in total

1.  Are clinically recommended pelvic floor muscle relaxation positions really efficient for muscle relaxation?

Authors:  Özge Çeliker Tosun; Damla Korkmaz Dayıcan; İrem Keser; Sefa Kurt; Meriç Yıldırım; Gökhan Tosun
Journal:  Int Urogynecol J       Date:  2022-02-24       Impact factor: 1.932

2.  Reliability of ultrasound imaging of the transversus abdominis muscle in asymptomatic subjects.

Authors:  Sin Ho Chung; Young Youl You
Journal:  J Phys Ther Sci       Date:  2015-05-26

3.  Measurement of superficial and deep abdominal muscle thickness: an ultrasonography study.

Authors:  Nahid Tahan; Khosro Khademi-Kalantari; Mohammad Ali Mohseni-Bandpei; Saeed Mikaili; Alireza Akbarzadeh Baghban; Shapour Jaberzadeh
Journal:  J Physiol Anthropol       Date:  2016-08-23       Impact factor: 2.867

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.