Literature DB >> 26154184

A randomized crossover study comparing a novel needle guidance technology for simulated internal jugular vein cannulation.

David B Auyong1, Stanley C Yuan, Alyse N Rymer, Cynthia L Green, Neil A Hanson.   

Abstract

BACKGROUND: Despite ultrasound guidance for central line placement, complications persist, as exact needle location is often difficult to confirm with standard two-dimension ultrasound. A novel real-time needle guidance technology has recently become available (eZono, Germany) that tracks the needle during insertion. This randomized, blinded, crossover study examined whether this needle guidance technology improved cannulation of a simulated internal jugular (IJ) vein in an ultrasound phantom.
METHODS: One hundred physicians were randomized to place a standard needle in an ultrasound neck phantom with or without the needle guidance system. Video cameras were placed externally and within the lumens of the vessels to record needle location in real time. The primary outcome measured was the rate of posterior wall puncture. Secondary outcomes included number of carotid artery punctures, number of needle passes, final needle position, time to cannulation, and comfort level with this new technology.
RESULTS: The incidence of posterior vessel wall puncture without and with needle guidance was 49 and 13%, respectively (P < 0.001, odds ratio [OR] = 7.33 [3.44 to 15.61]). The rate of carotid artery puncture was higher without needle navigation technology than with needle navigation 21 versus 2%, respectively (P = 0.001, OR = 12.97 [2.89 to 58.18]). Final needle tip position being located within the lumen of the IJ was 97% accurate with the navigation technology and 76% accurate with standard ultrasound (P < 0.001, OR = 10.42 [2.76 to 40.0]). Average time for successful vessel cannulation was 1.37 times longer without guidance technology.
CONCLUSION: This real-time needle guidance technology (eZono) shows significant improvement in needle accuracy and cannulation time during simulated IJ vein puncture.

Mesh:

Year:  2015        PMID: 26154184     DOI: 10.1097/ALN.0000000000000759

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  6 in total

1.  Comparison of in-plane and out-of-plane needle insertion with vs. without needle guidance.

Authors:  Verena Constanze Meiser; Helene Kreysa; Orlando Guntinas-Lichius; Gerd Fabian Volk
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-10-23       Impact factor: 2.503

2.  Agitated Saline Bubble-Enhanced Ultrasound for Assessing Appropriate Position of Hemodialysis Central Venous Catheter in Critically Ill Patients.

Authors:  Rogerio da Hora Passos; Michel Ribeiro; Julio Neves; Joao Gabriel Rosa Ramos; Adelmo Vinicius Lima Oliveira; Zilma Barreto; Rosseane Ferreira; Conrado Gomes; Paulo Benigno Pena Batista; Jean Jacques Rouby
Journal:  Kidney Int Rep       Date:  2017-04-07

3.  A novel electromagnetic guidance ultrasound system on radial artery cannulation: a prospective randomized controlled trial.

Authors:  Namo Kim; Hyun Il Kim; Do-Hyeong Kim; Dahee Park; Sei Han Song; Hyo-Jin Byon
Journal:  BMC Anesthesiol       Date:  2021-01-18       Impact factor: 2.217

4.  Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study.

Authors:  Haein Lee; Yoon Joo Cho; Eun Ju Ha; Jayoung Moon; You Na Kim; Minji Kim; Kyung-Min Lee; Sung Hyun An
Journal:  Ultrasonography       Date:  2021-12-10

5.  Ultrasound-guided lumbar puncture with a needle-guidance system: A prospective and controlled study to evaluate the learnability and feasibility of a newly developed approach.

Authors:  Tilo Backhaus; Moritz von Cranach; Jochen Brich
Journal:  PLoS One       Date:  2018-04-09       Impact factor: 3.240

6.  A Shallow Angle Short-Axis Out-of-Plane Approach Reduces the Rate of Posterior Wall Injuries in Central Venous Catheterization: A Simulation Study.

Authors:  Kunitaro Watanabe; Joho Tokumine; Alan Kawarai Lefor; Akira Motoyasu; Kumi Moriyama; Tomoko Yorozu
Journal:  Biomed Res Int       Date:  2018-09-10       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.