Flow cytometry is widely used in many laboratories for automated nucleated cell counts and their differentiation in body fluids. The implementation of new reflex testing rules on these automated instruments could open new frontiers in laboratory workflow, improving characterization of body fluids and clinical diagnosis and decreasing costs. Ascitic (150) and pleural (33) fluids were collected and assessed by XE-5000 and optical microscopy. Cell counts performed with the methods showed a Pearson's correlation of 0.98 (p < 0.0001), Passing-Bablok regression y = 0.99x + 2.44, and bias of 32.3. In ascitic fluids, the best diagnostic performance was found for polymorphonuclear and neutrophil counts on XE-5000, which exhibited areas under the curve (AUCs) 0.98 (p < 0.0001) and 0.99 (p < 0.0001), respectively. In pleural fluids the best diagnostic performance was found for polymorphonuclear percent parameter, which displayed 0.97 (p < 0.0001). Specific reflex test rules based on these parameters were characterized by 92% diagnostic concordance, 1.00 sensitivity, and 0.84 specificity with optical microscopy. The application of a set of reflex testing rules may improve the diagnostic performance of XE-5000, increasing its reliability for routine automated cell count in body fluids. We acknowledge that further studies should be planned to validate our findings according to clinical data.
© 2015 Society for Laboratory Automation and Screening.

Entities:  

Keywords:  XE-5000; automated cell count; body fluids; reflex testing rules

Mesh:

Year:  2015        PMID: 26149816     DOI: 10.1177/2211068215593375

Source DB:  PubMed          Journal:  J Lab Autom        ISSN: 2211-0682


  2 in total

1.  Automated and manual microscopic analyses for leukocyte differential counts in exudative pleural effusions: Real-world disagreement and clinical application.

Authors:  Jaehee Lee; Yu Kyung Kim; Ji Eun Park; Yong Hoon Lee; Sun Ha Choi; Hyewon Seo; Seung Soo Yoo; Shin Yup Lee; Seung-Ick Cha; Jae Yong Park; Chang Ho Kim
Journal:  Medicine (Baltimore)       Date:  2022-09-16       Impact factor: 1.817

2.  Performance Evaluation of Body Fluid Cellular Analysis Using the Beckman Coulter UniCel DxH 800, Sysmex XN-350, and UF-5000 Automated Cellular Analyzers.

Authors:  Jooyoung Cho; Joowon Oh; Sang Guk Lee; You Hee Lee; Jaewoo Song; Jeong Ho Kim
Journal:  Ann Lab Med       Date:  2020-03       Impact factor: 3.464

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.