Literature DB >> 26141753

Parathyroid function following total thyroidectomy using energy devices.

Fatih Ciftci1, Erdal Sakalli2, Ibrahim Abdurrahman3, Burak Guler4.   

Abstract

LigaSure precise (LP) and harmonic scalpel (HS) are two energy-based devices used in thyroidectomy surgery. We aimed to compare the effect of these two devices in patients who had undergone total thyroidectomy, by highlighting the post-operative parathyroid function. A total of 201 consecutive patients for whom total thyroidectomy had been planned were prospectively classified into two groups. There were 104 patients in LP group and 97 patients in HS group. Hypoparathyroidism was followed up by serially measuring the levels of intact parathyroid hormone (iPTH) and serum calcium. The early iPTH level was 29 (8-50) pg/mL in group LP, and 17 (4-43) pg/mL in group HS. The early iPTH level was significantly lower in the HS group (p < 0.001). However, these levels were within the reference interval in both groups. The early iPTH level was lower than 20 pg/mL in 23 (23.1 %) patients in HS group, and 15 (13.7 %) patients in LP group (p < 0.001). Also, the late iPTH levels were not statistically significance between two groups. The early and late serum calcium levels were not statistically significant between groups. However, the amount of calcium replacement was higher in the HS group than the LP group and the duration of treatment was longer in the HS group than the LP group (p < 0.05). In conclusion, although parathyroid hormone levels impaired in the HS group more than LP group in the early period, these levels were in the normal limits in both groups. These levels were not significant between groups in the long time period.

Entities:  

Keywords:  Harmonic scalpel; Hypocalcemia; Hypoparathyroidism; LigaSure; Thyroidectomy

Mesh:

Substances:

Year:  2015        PMID: 26141753     DOI: 10.1007/s00405-015-3704-8

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  23 in total

1.  Real-time thermography during energized vessel sealing and dissection.

Authors:  P A Campbell; A B Cresswell; T G Frank; A Cuschieri
Journal:  Surg Endosc       Date:  2003-07-21       Impact factor: 4.584

Review 2.  Influence of new technologies on thyroid surgery: state of the art.

Authors:  Gianlorenzo Dionigi; Alessandro Bacuzzi; Luigi Boni; Francesca Rovera; Eliana Piantanida; Maria Laura Tanda; Mario Diurni; Giulio Carcano; Bartalena Luigi; Salvatore Cuffari; Renzo Dionigi
Journal:  Expert Rev Med Devices       Date:  2005-09       Impact factor: 3.166

3.  Impact of modern technologies on quality of thyroid surgery.

Authors:  Henning Dralle
Journal:  Langenbecks Arch Surg       Date:  2006-02       Impact factor: 3.445

4.  Transplantation of the parathyroid glands in man: clinical indications and results.

Authors:  S A Wells; J C Gunnells; J D Shelburne; A B Schneider; L M Sherwood
Journal:  Surgery       Date:  1975-07       Impact factor: 3.982

5.  Applicability of intraoperative parathyroid hormone assay during thyroidectomy.

Authors:  Chung Yau Lo; John M Luk; Sidney C Tam
Journal:  Ann Surg       Date:  2002-11       Impact factor: 12.969

6.  [Complications in thyroid surgery: symptomatic post-operative hypoparathyroidism incidence, surgical technique, and treatment].

Authors:  Carmelo Sciumè; Girolamo Geraci; Franco Pisello; Tiziana Facella; Francesco Li Volsi; Antonella Licata; Giuseppe Modica
Journal:  Ann Ital Chir       Date:  2006 Mar-Apr       Impact factor: 0.766

7.  Infrared thermographic profiles of vessel sealing devices on thyroid parenchyma.

Authors:  Carter T Smith; Barbara Zarebczan; Amal Alhefdhi; Herbert Chen
Journal:  J Surg Res       Date:  2011-03-29       Impact factor: 2.192

8.  Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy.

Authors:  Yoann Pons; Jérome Gauthier; Elsa Ukkola-Pons; Philippe Clément; Eric Roguet; Jean-Luc Poncet; Claude Conessa
Journal:  Otolaryngol Head Neck Surg       Date:  2009-10       Impact factor: 3.497

9.  Safely increasing the efficiency of thyroidectomy using a new bipolar electrosealing device (LigaSure) versus conventional clamp-and-tie technique.

Authors:  Jan Franko; Karen J Kish; Christopher M Pezzi; Ho Pak; John S Kukora
Journal:  Am Surg       Date:  2006-02       Impact factor: 0.688

10.  Comparing scalpel, electrocautery and ultrasonic dissector effects: the impact on wound complications and pro-inflammatory cytokine levels in wound fluid from mastectomy patients.

Authors:  Kerim Bora Yilmaz; Lutfi Dogan; Handan Nalbant; Melih Akinci; Niyazi Karaman; Cihangir Ozaslan; Hakan Kulacoglu
Journal:  J Breast Cancer       Date:  2011-03-31       Impact factor: 3.588

View more
  2 in total

1.  Parathyroid hormone level after total thyroidectomy using conventional versus harmonic focus technique: Prospective randomized study.

Authors:  Hany Abdelfatah Elhady; Rasha Abd Elaziz Abd Elghany; Mohammed Shehata Zarad
Journal:  Ann Med Surg (Lond)       Date:  2021-12-14

2.  Novel application of microdissection tungsten needle in total thyroidectomy with central neck dissection for papillary thyroid carcinoma.

Authors:  Weijie Zheng; Shan Zhu; Yimin Zhang; Zhong Wang; Shichong Liao; Shengrong Sun
Journal:  Front Surg       Date:  2022-08-26
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.