Literature DB >> 26138730

Initial experience of coiling cerebral aneurysms using the new Comaneci device.

Aimee Louise Deborah Lawson1, Arun Chandran2, Mani Puthuran2, Tony Goddard3, Hans Nahser4, Tufail Patankar3.   

Abstract

We present our initial patient experience with an innovative temporary bridging device, the Comaneci (Rapid Medical, Israel), to assist in the coiling of cerebral aneurysms. The Comaneci device confers the same benefits as balloon remodeling but without the risks of parent artery occlusion. This alleviates time pressure on the clinician, and could reduce the risk of parent artery thrombosis. Three patients were treated with the Comaneci device. Two patients had acute ruptured posterior communicating aneurysms and one patient was treated electively for a carotico-ophthalmic aneurysm. Excellent occlusion of all three aneurysms was obtained. One patient developed a distal middle cerebral artery clot, that was treated with intravenous aspirin, with minor neurological consequences. These early results show that the Comaneci device can be used to achieve good cerebral aneurysm occlusion. Vessel patency is maintained throughout the procedure with potential advantages over conventional balloon assisted coiling. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

Entities:  

Keywords:  Aneurysm; Angiography; Brain; Device; Intervention

Mesh:

Year:  2015        PMID: 26138730     DOI: 10.1136/neurintsurg-2015-011726.rep

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  4 in total

1.  Early Experience with Comaneci, a Newly FDA-Approved Controllable Assist Device for Wide-Necked Intracranial Aneurysm Coiling.

Authors:  M Asif Taqi; Eytan Raz; Anastasia Vechera; Maksim Shapiro; Rishi Gupta; Joseph Haynes; Philipp Taussky; Ramesh Grandhi; Howard A Riina; Peter Kim Nelson; Erez Nossek
Journal:  Cerebrovasc Dis       Date:  2021-05-10       Impact factor: 2.762

2.  The Cascade device - In vitro tests to assess coil protrusion into the parent vessel.

Authors:  P Bhogal; K Wong; Hld Makalanda
Journal:  Interv Neuroradiol       Date:  2020-05-11       Impact factor: 1.610

3.  Coiling of wide-necked carotid artery aneurysms assisted by a temporary bridging device (Comaneci): preliminary experience.

Authors:  S Fischer; A Weber; A Carolus; F Drescher; F Götz; W Weber
Journal:  J Neurointerv Surg       Date:  2016-10-14       Impact factor: 5.836

4.  Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique.

Authors:  Stanimir S Sirakov; Alexander Sirakov; Hristo Hristov; Radoslav Raychev