Literature DB >> 32393085

The Cascade device - In vitro tests to assess coil protrusion into the parent vessel.

P Bhogal1, K Wong1, Hld Makalanda1.   

Abstract

BACKGROUND: Balloon and stent-assisted coiling of aneurysms have increased the number of aneurysms available for endovascular treatment. Newer devices that allow flow within the parent vessel but coverage at the neck have recently entered the market. The Cascade is a new non-occlusive fully retrievable neck-bridging support device that has been designed to provide temporary support during coil embolisation of intracranial aneurysms.
METHODS: Using a silicone aneurysm model three different aneurysms were catheterised with the coiling microcatheter placed in three different positions within each aneurysm - at the neck, centrally, and looped within the aneurysm. Multiple different coils were then deployed within each aneurysm with the Cascade device deployed across the neck to provide protection. In total 480 attempted coilings were performed. Aneurysm flow was used to calculate the change in intra-aneurysmal flow with the Cascade device deployed across the neck of the aneurysm.
RESULTS: We did not observe a single episode of coil protrusion through the Cascade mesh nor did we observe any coil protrusion into the parent vessel when the Cascade was deployed across the neck. There was an average flow velocity reduction of 23% with the Cascade device deployed across the neck of the aneurysm.
CONCLUSION: The Cascade device offers robust protection of the aneurysmal neck and parent vessel as well as inducing significant intra-aneurysmal flow velocity reduction.

Entities:  

Keywords:  Cascade; aneurysm; aneurysm flow

Mesh:

Year:  2020        PMID: 32393085      PMCID: PMC7446591          DOI: 10.1177/1591019920925708

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  21 in total

1.  Balloon-assisted coil embolization of intracranial aneurysms: incidence, complications, and angiography results.

Authors:  Menno Sluzewski; Willem Jan van Rooij; Guus N Beute; Peter C Nijssen
Journal:  J Neurosurg       Date:  2006-09       Impact factor: 5.115

2.  Early experience with a temporary bridging device (Comaneci) in the endovascular treatment of ruptured wide neck aneurysms.

Authors:  Stanimir Sirakov; Alexander Sirakov; Hristo Hristov; Krasimir Minkin; Marin Penkov; Vasil Karakostov
Journal:  J Neurointerv Surg       Date:  2018-02-06       Impact factor: 5.836

3.  Understanding Angiography-Based Aneurysm Flow Fields through Comparison with Computational Fluid Dynamics.

Authors:  J R Cebral; F Mut; B J Chung; L Spelle; J Moret; F van Nijnatten; D Ruijters
Journal:  AJNR Am J Neuroradiol       Date:  2017-04-06       Impact factor: 3.825

Review 4.  Stent-assisted coiling in acutely ruptured intracranial aneurysms: a qualitative, systematic review of the literature.

Authors:  K D Bodily; H J Cloft; G Lanzino; D J Fiorella; P M White; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2011-05-05       Impact factor: 3.825

5.  Treatment of ruptured blood blister-like aneurysms with flow diverter SILK stents.

Authors:  Kubilay Aydin; Anil Arat; Serra Sencer; Bahattin Hakyemez; Mehmet Barburoglu; Altay Sencer; Nail İzgi
Journal:  J Neurointerv Surg       Date:  2014-02-03       Impact factor: 5.836

6.  A DSA-based method using contrast-motion estimation for the assessment of the intra-aneurysmal flow changes induced by flow-diverter stents.

Authors:  V M Pereira; O Bonnefous; R Ouared; O Brina; J Stawiaski; H Aerts; D Ruijters; A P Narata; P Bijlenga; K Schaller; K-O Lovblad
Journal:  AJNR Am J Neuroradiol       Date:  2012-11-01       Impact factor: 3.825

7.  Early experience with a novel net temporary bridging device (Cascade) to assist endovascular coil embolization of intracranial aneurysms.

Authors:  Alejandro Tomasello; David Hernandez; Laura Ludovica Gramegna; Sonia Aixut; Roger Barranco Pons; Olav Jansen; Michal Zawadzki; Antonio Lopez-Rueda; Carmen Parra-Fariñas; Carlos Piñana; Lavinia Dinia; Fuat Arikan; Alex Rovira
Journal:  J Neurosurg       Date:  2020-01-24       Impact factor: 5.115

8.  Intra-aneurysmal flow disruption after implantation of the Medina® Embolization Device depends on aneurysm neck coverage.

Authors:  Andreas Maximilian Frölich; Marie Teresa Nawka; Marielle Ernst; Isabell Frischmuth; Jens Fiehler; Jan-Hendrik Buhk
Journal:  PLoS One       Date:  2018-02-06       Impact factor: 3.240

9.  Flow Diversion for Treatment of Acutely Ruptured Intracranial Aneurysms : A Single Center Experience from 45 Consecutive Cases.

Authors:  Muhammad AlMatter; Marta Aguilar Pérez; Victoria Hellstern; Goran Mitrovic; Oliver Ganslandt; Hansjörg Bäzner; Hans Henkes
Journal:  Clin Neuroradiol       Date:  2019-11-04       Impact factor: 3.649

10.  The use of flow diverters to treat small (≤5 mm) ruptured, saccular aneurysms.

Authors:  Pervinder Bhogal; Elina Henkes; Stefan Schob; Muhammad AlMatter; Victoria Hellstern; Hansjörg Bäzner; Oliver Ganslandt; Hans Henkes; Marta Aguilar Pérez
Journal:  Surg Neurol Int       Date:  2018-10-30
View more
  1 in total

Review 1.  Application of the Neuroform Atlas Stent in Intracranial Aneurysms: Current Status.

Authors:  Kun Hou; Jinlu Yu
Journal:  Front Neurol       Date:  2022-03-25       Impact factor: 4.003

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.