Literature DB >> 2613743

Corrosion of copper, nickel, and gold dental casting alloys: an in vitro and in vivo study.

B I Johansson1, L C Lucas, J E Lemons.   

Abstract

The corrosion behavior of commercially available copper, nickel, and gold alloys for dental castings was investigated. The alloys investigated included: three copper alloys (76-87Cu, 6-11A1, 0-12Zn, 1-5Ni, 0-4Fe, 0.5-1.2Mn), two nickel alloys (68-78Ni, 12-16Cr, 4-14Mo, 0-1.7Be), and one gold alloy (77Au, 14Ag, 8Cu, 1Pd). Anodic and cathodic polarization curves, long-term immersion tests in saline and artificial saliva solutions, and dog crown studies were conducted to evaluate both the in vitro and in vivo corrosion characteristics of the alloys. All evaluations conducted demonstrated that the copper alloys were highly susceptible to corrosion attack. High corrosion currents were observed in the in vitro tests, and SEM of the alloys specimens showed significantly altered surfaces. The anodic polarization curves predicted that the beryllium-containing nickel alloy should be susceptible to localized corrosion and SEM revealed an etched surface with corrosion of certain microstructural features. No significant corrosion was predicted or observed for the non-beryllium nickel alloy and the gold alloy. The in vitro corrosion evaluations predicted the in vivo corrosion behavior for the alloys. Since the three copper alloys and the beryllium-containing nickel alloy demonstrated significant corrosion under the tested conditions, the use of these alloys for restorative procedures is questionable due to the release of significant levels of selected ions to the oral cavity.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2613743     DOI: 10.1002/jbm.820231409

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  6 in total

1.  Galvanic corrosion behavior of titanium implants coupled to dental alloys.

Authors:  M Cortada; L Giner; S Costa; F J Gil; D Rodríguez; J A Planell
Journal:  J Mater Sci Mater Med       Date:  2000-05       Impact factor: 3.896

2.  [An in-vitro study of the interference of orthodontic banding and filling materials].

Authors:  M A Baumann; K Samanek; T Ruppenthal
Journal:  Fortschr Kieferorthop       Date:  1992-08

3.  Biocompatibility of orthodontic bands following exposure to dental plaque.

Authors:  Sandra Hornikel; Christina Erbe; Irene Schmidtmann; Heiner Wehrbein
Journal:  J Orofac Orthop       Date:  2011-04-20       Impact factor: 1.938

4.  Surface characterization of passive film and elemental release analysis of a Ni-Cr alloy during bleaching, part I: effects of different bleaching agents.

Authors:  Evşen Tamam; A Kevser Aydın
Journal:  Clin Oral Investig       Date:  2010-03-09       Impact factor: 3.573

5.  Dental casting alloys behaviour during power toothbrushing with toothpastes of various abrasivities. Part II: corrosion and ion release.

Authors:  C Molina; Ll Nogués; J Martinez-Gomis; M Peraire; J Salsench; P Sevilla; F J Gil
Journal:  J Mater Sci Mater Med       Date:  2008-04-04       Impact factor: 3.896

Review 6.  Corrosion degradation and prevention by surface modification of biometallic materials.

Authors:  Raghuvir Singh; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2006-12-02       Impact factor: 4.727

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.