Literature DB >> 18389346

Dental casting alloys behaviour during power toothbrushing with toothpastes of various abrasivities. Part II: corrosion and ion release.

C Molina1, Ll Nogués, J Martinez-Gomis, M Peraire, J Salsench, P Sevilla, F J Gil.   

Abstract

The purpose of this study was to evaluate the long term effect of abrasivity of toothpastes normally used over the corrosion behavior and ion release of the different dental casting alloys. Three dental casting alloys (Ni-Cr, Co-Cr and commercially pure Ti) were studied. Four specimens of each material were immersed, brushed without paste or brushed with one of four toothpastes of different Relative Dentine Abrasivity (RDA 50, 52, 80, and 114). An electric toothbrush with a load of 250 g was used for 420 min. Corrosion behavior was determined by means a potenciostat with high sensitivity and the ion release determined by Inductively Coupled Plasma-Mass Spectrometry. Two-way ANOVA and non-parametric tests were used to detect significant differences. Titanium specimens exhibited the best corrosion behavior after and before the toothbrushed, being the worst of the three alloys the Cr-Ni. Titanium oxide produced spontaneously on the Ti surface is the main cause of the high corrosion resistance of the material. However, the eutectoid of the CrNi with chemical composition between different phases produces pitting on the phases boundaries with an important decrease of the corrosion resistance. Besides, the CrNi produces high values of the Ni and Cr release. Slight increment in roughness were observed after toothbrushing and depended on the material but not on the toothpaste used. The increase of the microhardness (residual stresses) provokes a decrease of the corrosion resistance and an increase of the ion release.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18389346     DOI: 10.1007/s10856-008-3432-3

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  19 in total

1.  Surface hardening by anodizing and heat treatments of Ti6Al4V alloys for articular prostheses.

Authors:  F J Gil; M P Ginebra; J A Planell
Journal:  Biomed Mater Eng       Date:  2002       Impact factor: 1.300

2.  Ion release from NiTi orthodontic wires in artificial saliva with various acidities.

Authors:  Her-Hsiung Huang; Yu-Hui Chiu; Tzu-Hsin Lee; Shih-Ching Wu; Hui-Wen Yang; Kuo-Hsiung Su; Chii-Chih Hsu
Journal:  Biomaterials       Date:  2003-09       Impact factor: 12.479

3.  Corrosion of copper, nickel, and gold dental casting alloys: an in vitro and in vivo study.

Authors:  B I Johansson; L C Lucas; J E Lemons
Journal:  J Biomed Mater Res       Date:  1989-12

4.  Ability of Ni-containing biomedical alloys to activate monocytes and endothelial cells in vitro.

Authors:  J C Wataha; P E Lockwood; M Marek; M Ghazi
Journal:  J Biomed Mater Res       Date:  1999-06-05

5.  In vitro corrosion measurements of dental alloys.

Authors:  J Geis-Gerstorfer
Journal:  J Dent       Date:  1994-08       Impact factor: 4.379

6.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw.

Authors:  R Adell; U Lekholm; B Rockler; P I Brånemark
Journal:  Int J Oral Surg       Date:  1981-12

7.  Measurement of in vivo corrosion rates in baboons, and correlation with in vitro tests.

Authors:  L Gettleman; F H Cocks; L A Darmiento; P A Levine; S Wright; D Nathanson
Journal:  J Dent Res       Date:  1980-04       Impact factor: 6.116

8.  In vitro corrosion and tarnish analysis of the Ag-Pd binary system.

Authors:  T K Vaidyanathan; A Prasad
Journal:  J Dent Res       Date:  1981-03       Impact factor: 6.116

Review 9.  Metal release from dental biomaterials.

Authors:  D Brune
Journal:  Biomaterials       Date:  1986-05       Impact factor: 12.479

10.  Titanium levels in rats implanted with Ti6Al4V treated samples in the absence of wear.

Authors:  D Rodríguez; F J Gil; J A Planell; E Jorge; L Alvarez; R García; M Larrea; A Zapata
Journal:  J Mater Sci Mater Med       Date:  1999-12       Impact factor: 3.896

View more
  3 in total

1.  Brushing-induced surface roughness of two nickel based alloys and a titanium based alloy: a comparative study - in vitro study.

Authors:  B L Guruprasanna Acharya; Ramesh Nadiger; Bharathraj Shetty; G Gururaj; K Naveen Kumar; D D Darshan
Journal:  J Int Oral Health       Date:  2014-06-26

2.  The effect of pretreating resorbable blast media titanium discs with an ultrasonic scaler or toothbrush on the bacterial removal efficiency of brushing.

Authors:  Minchul Koh; Jun-Beom Park; Yun-Ji Jang; Youngkyung Ko
Journal:  J Periodontal Implant Sci       Date:  2013-12-31       Impact factor: 2.614

3.  Corrosion Behavior of a Nickel-Base Dental Casting Alloy in Artificial Saliva Studied by Weight Loss and Polarization Techniques.

Authors:  Elnaz Moslehifard; Mahsa Moslehifard; Sanaz Ghasemzadeh; Farzad Nasirpouri
Journal:  Front Dent       Date:  2019-01-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.