Literature DB >> 26126796

Concurrent validity and reliability of a novel wireless inertial measurement system to assess trunk movement.

C M Bauer1, F M Rast2, M J Ernst2, J Kool2, S Oetiker2, S M Rissanen3, J H Suni4, M Kankaanpää5.   

Abstract

INTRODUCTION: Assessment of movement dysfunctions commonly comprises trunk range of motion (ROM), movement or control impairment (MCI), repetitive movements (RM), and reposition error (RE). Inertial measurement unit (IMU)-systems could be used to quantify these movement dysfunctions in clinical settings. The aim of this study was to evaluate a novel IMU-system when assessing movement dysfunctions in terms of concurrent validity and reliability.
METHODS: The concurrent validity of the IMU-system was tested against an optoelectronic system with 22 participants. The reliability of 14 movement dysfunction tests were analysed using generalizability theory and coefficient of variation, measuring 24 participants in seven trials on two days.
RESULTS: The IMU-system provided valid estimates of trunk movement in the primary movement direction when compared to the optoelectronic system. Reliability varied across tests and variables. On average, ROM and RM were more reliable, compared to MCI and RE tests. DISCUSSION: When compared to the optoelectronic system, the IMU-system is valid for estimates of trunk movement in the primary movement direction. Four ROM, two MCI, one RM, and one RE test were identified as reliable and should be studied further for inter-subject comparisons and monitoring changes after an intervention.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biomechanical phenomena; Generalizability-theory; Movement disorders; Reproducibility of results

Mesh:

Year:  2015        PMID: 26126796     DOI: 10.1016/j.jelekin.2015.06.001

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  13 in total

Review 1.  A review of computational approaches for evaluation of rehabilitation exercises.

Authors:  Yalin Liao; Aleksandar Vakanski; Min Xian; David Paul; Russell Baker
Journal:  Comput Biol Med       Date:  2020-03-04       Impact factor: 4.589

2.  Accuracy and Repeatability of Spatiotemporal Gait Parameters Measured with an Inertial Measurement Unit.

Authors:  Jorge Posada-Ordax; Julia Cosin-Matamoros; Marta Elena Losa-Iglesias; Ricardo Becerro-de-Bengoa-Vallejo; Laura Esteban-Gonzalo; Carlos Martin-Villa; César Calvo-Lobo; David Rodriguez-Sanz
Journal:  J Clin Med       Date:  2021-04-21       Impact factor: 4.241

3.  Medicine in spine exercise (MiSpEx) for nonspecific low back pain patients: study protocol for a multicentre, single-blind randomized controlled trial.

Authors:  Daniel Niederer; Lutz Vogt; Pia-Maria Wippert; Anne-Katrin Puschmann; Ann-Christin Pfeifer; Marcus Schiltenwolf; Winfried Banzer; Frank Mayer
Journal:  Trials       Date:  2016-10-20       Impact factor: 2.279

4.  Reproducibility and discriminant validity of two clinically feasible measurement methods to obtain coronal plane gait kinematics in participants with a lower extremity amputation.

Authors:  Ruud A Leijendekkers; Thomas J Hoogeboom; Gerben van Hinte; Lars Didden; Thomas Anijs; Maria W G Nijhuis-van der Sanden; Nico Verdonschot
Journal:  PLoS One       Date:  2019-05-21       Impact factor: 3.240

5.  Changes in Lumbopelvic Movement and Muscle Recruitment Associated with Prolonged Deep Squatting: A Pilot Study.

Authors:  Tim K S Lui; Sharon M H Tsang; Anthony W L Kwok
Journal:  Int J Environ Res Public Health       Date:  2018-05-16       Impact factor: 3.390

6.  Validity of shoe-type inertial measurement units for Parkinson's disease patients during treadmill walking.

Authors:  Myeounggon Lee; Changhong Youm; Jeanhong Jeon; Sang-Myung Cheon; Hwayoung Park
Journal:  J Neuroeng Rehabil       Date:  2018-05-15       Impact factor: 4.262

7.  Comparison of a Low-Cost Miniature Inertial Sensor Module and a Fiber-Optic Gyroscope for Clinical Balance and Gait Assessments.

Authors:  Daniel Roetenberg; Claudia Höller; Kevin Mattmüller; Markus Degen; John H Allum
Journal:  J Healthc Eng       Date:  2019-09-25       Impact factor: 2.682

8.  Application-Based Production and Testing of a Core-Sheath Fiber Strain Sensor for Wearable Electronics: Feasibility Study of Using the Sensors in Measuring Tri-Axial Trunk Motion Angles.

Authors:  Ahmad Rezaei; Tyler J Cuthbert; Mohsen Gholami; Carlo Menon
Journal:  Sensors (Basel)       Date:  2019-10-03       Impact factor: 3.576

9.  Concurrent Validity of a Novel Wireless Inertial Measurement System for Assessing Trunk Impairment in People with Stroke.

Authors:  Norah Alhwoaimel; Martin Warner; Ann-Marie Hughes; Federico Ferrari; Jane Burridge; Seng Kwee Wee; Geert Verheyden; Ruth Turk
Journal:  Sensors (Basel)       Date:  2020-03-18       Impact factor: 3.576

10.  A Two Joint Neck Model to Identify Malposition of the Head Relative to the Thorax.

Authors:  Philipp M Schmid; Christoph M Bauer; Markus J Ernst; Bettina Sommer; Lars Lünenburger; Martin Weisenhorn
Journal:  Sensors (Basel)       Date:  2021-05-10       Impact factor: 3.576