Literature DB >> 26125298

Low-Dose Pelvic Computed Tomography Using Adaptive Iterative Dose Reduction 3-Dimensional Algorithm: A Phantom Study.

Hiromitsu Onishi1, Remko Kockelkoren, Tonsok Kim, Masatoshi Hori, Atsushi Nakamoto, Takahiro Tsuboyama, Makoto Sakane, Mitsuaki Tatsumi, Ayumi Uranishi, Toshiya Tanaka, Akira Taniguchi, Yukihiro Enchi, Kazuhiko Satoh, Noriyuki Tomiyama.   

Abstract

OBJECTIVE: To evaluate the image quality and radiation dose reduction in pelvic computed tomography (CT) achieved with an adaptive iterative dose reduction 3-dimensional (AIDR 3D) algorithm using a phantom model.
METHODS: Two phantoms were scanned using a 320-detector row CT scanner with 8 tube current levels, and the images were reconstructed with a standard filtered back projection (FBP) algorithm and with an AIDR 3D algorithm.
RESULTS: Compared with FBP, AIDR 3D reduced image noise and improved contrast-to-noise ratios. The diagnostic performance for detection of low-contrast targets of AIDR 3D images obtained with 100 mA at 120 kVp was almost as good as that of the FBP images obtained with 200 mA.
CONCLUSIONS: The AIDR 3D algorithm substantially reduced image noise and improved the image quality of pelvic CT images compared with those obtained with the FBP algorithm and can thus be considered a promising technique for low-dose pelvic CT examinations.

Mesh:

Year:  2015        PMID: 26125298     DOI: 10.1097/RCT.0000000000000242

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  3 in total

1.  Diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction algorithm for the detection of hypervascular liver lesions: a phantom study.

Authors:  Atsushi Nakamoto; Yoshikazu Tanaka; Hiroshi Juri; Go Nakai; Shushi Yoshikawa; Yoshifumi Narumi
Journal:  Eur Radiol       Date:  2016-12-12       Impact factor: 5.315

2.  Image quality and radiologists' subjective acceptance using model-based iterative and deep learning reconstructions as adjuncts to ultrahigh-resolution CT in low-dose contrast-enhanced abdominopelvic CT: phantom and clinical pilot studies.

Authors:  Makiko Nishikawa; Haruhiko Machida; Yuta Shimizu; Toshiya Kariyasu; Hiroyuki Morisaka; Takuya Adachi; Takehiro Nakai; Kosuke Sakaguchi; Shun Saito; Saki Matsumoto; Masamichi Koyanagi; Kenichi Yokoyama
Journal:  Abdom Radiol (NY)       Date:  2021-12-16

3.  Reduction of the radiation dose and the amount of contrast material in hepatic dynamic CT using low tube voltage and adaptive iterative dose reduction 3-dimensional.

Authors:  Atsushi Nakamoto; Kiyohito Yamamoto; Makoto Sakane; Go Nakai; Akira Higashiyama; Hiroshi Juri; Shushi Yoshikawa; Yoshifumi Narumi
Journal:  Medicine (Baltimore)       Date:  2018-08       Impact factor: 1.817

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.