Literature DB >> 26117334

Trade-off between stress shielding and initial stability on an anatomical cementless stem shortening: in-vitro biomechanical study.

Go Yamako1, Etsuo Chosa2, Koji Totoribe2, Shinji Watanabe2, Takero Sakamoto2.   

Abstract

Shortened cementless femoral stems have become popular with the advent of minimally invasive total hip arthroplasty (THA). Successful THA requires initial stem stability and prevention of stress shielding-mediated bone loss, although the effect of stem shortening is controversial. Here we experimentally examined whether stem shortening affects stress shielding and initial stability. Anatomical stems (length, 120 mm) were cut to an 80 mm or 50 mm length. Ten tri-axial strain gauges measured the cortical strain on each stem-implanted femur to evaluate stress shielding. Two transducers measured axial relative displacement and rotation under single-leg stance loading. The 50 mm stem increased the equivalent strains with respect to the original stem in the proximal calcar region (31.0% relative to intact strain), proximal medial region (63.1%), and proximal lateral region (53.9%). In contrast, axial displacement and rotation increased with a decreasing stem length. However, the axial displacement of the 50 mm stem was below a critical value of 150 µm for bone ingrowth. Our findings indicate that, with regard to a reduction in stem length, there is a tradeoff between stress shielding and initial stability. Shortening the stem up to 50 mm can promote proximal load transfer, but bone loss would be inevitable, even with sufficient initial stability for long-term fixation.
Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Anatomical stem; Initial stability; Short stem; Stress shielding; Total hip arthroplasty

Mesh:

Year:  2015        PMID: 26117334     DOI: 10.1016/j.medengphy.2015.05.017

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  4 in total

1.  Evolution of Microstructural and Mechanical Properties during Cold-Rolling Deformation of a Biocompatible Ti-Nb-Zr-Ta Alloy.

Authors:  Alexandru Dan; Mariana Lucia Angelescu; Nicolae Serban; Elisabeta Mirela Cojocaru; Nicoleta Zarnescu-Ivan; Vasile Danut Cojocaru; Bogdan Mihai Galbinasu
Journal:  Materials (Basel)       Date:  2022-05-17       Impact factor: 3.748

2.  Short to Midterm Follow-Up of Periprosthetic Bone Mineral Density after Total Hip Arthroplasty with the Ribbed Anatomic Stem.

Authors:  Xiang-Dong Wu; Mian Tian; Yao He; Hong Chen; Yu Chen; Rahul Mishra; Wei Liu; Wei Huang
Journal:  Biomed Res Int       Date:  2019-06-27       Impact factor: 3.411

3.  Short stems have lower load at failure than double-wedged stems in a cadaveric cementless fracture model.

Authors:  Antonio Klasan; Martin Bäumlein; Philipp Dworschak; Christopher Bliemel; Thomas Neri; Markus D Schofer; Thomas J Heyse
Journal:  Bone Joint Res       Date:  2019-11-02       Impact factor: 5.853

4.  Quantifying the degradation of degradable implants and bone formation in the femoral condyle using micro-CT 3D reconstruction.

Authors:  Yichi Xu; Haoye Meng; Heyong Yin; Zhen Sun; Jiang Peng; Xiaolong Xu; Quanyi Guo; Wenjing Xu; Xiaoming Yu; Zhiguo Yuan; Bo Xiao; Cheng Wang; Yu Wang; Shuyun Liu; Shibi Lu; Zhaoxu Wang; Aiyuan Wang
Journal:  Exp Ther Med       Date:  2017-10-30       Impact factor: 2.447

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.