Literature DB >> 26117242

A cost-effective technique for cardiac sparing with deep inspiration-breath hold (DIBH).

Bryan D Macrie1, Eric D Donnelly1, John P Hayes1, Mahesh Gopalakrishnan2, Rino T Philip2, Jozef Reczek2, Adam Prescott2, Jonathan B Strauss3.   

Abstract

Deep inspiration breath hold (DIBH) is an effective technique to reduce cardiac and pulmonary dose during breast radiotherapy (RT). However, as a result of expense and the technical challenges of program implementation, DIBH has not been widely adopted in clinical practice. This report describes a program for DIBH this is relatively inexpensive to implement and has little impact on patient throughput. Multiple redundant mechanisms are incorporated to assure accurate and safe delivery of RT during DIBH. Laser alignment verifies that chest wall excursion is reliably reproduced and maintained during treatment. Chest wall excursion is also monitored independently using an infrared camera trained on a reflective marker on the chest wall. This system automatically triggers "beam off" in the event of movement of the target beyond pre-determined thresholds. Finally, physician review of cine imaging obtained during treatment provides an off-line verification of accurate RT delivery. The approach described herein lowers the investment necessary for implementation of DIBH and may facilitate broader adoption of this valuable technique.
Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Breast cancer; Cardiac sparing; DIBH; Deep inspiratory breath hold; IGRT; Radiotherapy

Mesh:

Year:  2015        PMID: 26117242     DOI: 10.1016/j.ejmp.2015.06.006

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  12 in total

1.  Interfractional diaphragm changes during breath-holding in stereotactic body radiotherapy for liver cancer.

Authors:  Daisuke Kawahara; Shuichi Ozawa; Takeo Nakashima; Shintaro Tsuda; Yusuke Ochi; Takuro Okumura; Hirokazu Masuda; Kazunari Hioki; Tathsuhiko Suzuki; Yoshimi Ohno; Tomoki Kimura; Yuji Murakami; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2018-02-10

2.  Radiotherapy of MRI-detected involved internal mammary lymph nodes in breast cancer.

Authors:  Sean Sachdev; Chelain R Goodman; Erin Neuschler; Kapila Kalakota; Daniel Cutright; Eric D Donnelly; John P Hayes; Adam E Prescott; Gianna Mirabelli; Jonathan B Strauss
Journal:  Radiat Oncol       Date:  2017-12-19       Impact factor: 3.481

3.  Development of a deep inspiration breath-hold system for radiotherapy utilizing a laser distance measurer.

Authors:  Christer Andre Jensen; Nils Skottner; Jomar Frengen; Jo-Åsmund Lund
Journal:  J Appl Clin Med Phys       Date:  2016-11-24       Impact factor: 2.102

Review 4.  Deep Inspiration Breath Hold: Techniques and Advantages for Cardiac Sparing During Breast Cancer Irradiation.

Authors:  Carmen Bergom; Adam Currey; Nina Desai; An Tai; Jonathan B Strauss
Journal:  Front Oncol       Date:  2018-04-04       Impact factor: 6.244

5.  Monitoring deep inspiration breath hold for left-sided localized breast cancer radiotherapy with an in-house developed laser distance meter system.

Authors:  Christer A Jensen; Tatiana Abramova; Jomar Frengen; Jo-Åsmund Lund
Journal:  J Appl Clin Med Phys       Date:  2017-07-29       Impact factor: 2.102

6.  Abdominal DIBH reduces the cardiac dose even further: a prospective analysis.

Authors:  Feng Zhao; Jiayan Shen; Zhongjie Lu; Yongbiao Luo; Guorong Yao; Luyi Bu; Jia Ge; Xin Yang; Lihua Ning; Senxiang Yan
Journal:  Radiat Oncol       Date:  2018-06-22       Impact factor: 3.481

7.  Which technique of positioning and immobilization is better for breast cancer patients in postmastectomy IMRT, single-pole or double-pole immobilization?

Authors:  Qun Xiang; Wuyun Jie; KuiKui Zhu; Qiong Wang; Jing Cheng
Journal:  J Appl Clin Med Phys       Date:  2018-12-03       Impact factor: 2.102

8.  Design and Construction of A Laser-Based Respiratory Gating System For Implementation of Deep Inspiration Breathe Hold Technique in Radiotherapy Clinics.

Authors:  Mohammad Javad Keikhai Farzaneh; Shahrokh Nasseri; Mehdi Momennezhad; Roham Salek
Journal:  J Med Signals Sens       Date:  2018 Oct-Dec

9.  Study on the Effect of 4D-CT Special Reconstruction Images for Evaluation of the Cardiac Structure Dose in Radiotherapy for Breast Cancer.

Authors:  Ming Su; Guanzhong Gong; Xiaoping Qiu; Ying Tong; Qian Li; Yong Yin
Journal:  Front Oncol       Date:  2020-03-31       Impact factor: 6.244

10.  Dose reduction to organs at risk with deep-inspiration breath-hold during right breast radiotherapy: a treatment planning study.

Authors:  Chloe Pandeli; Lloyd M L Smyth; Steven David; Andrew W See
Journal:  Radiat Oncol       Date:  2019-12-10       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.