Literature DB >> 26114033

An adaptive optics imaging system designed for clinical use.

Jie Zhang1, Qiang Yang1, Kenichi Saito2, Koji Nozato2, David R Williams3, Ethan A Rossi4.   

Abstract

Here we demonstrate a new imaging system that addresses several major problems limiting the clinical utility of conventional adaptive optics scanning light ophthalmoscopy (AOSLO), including its small field of view (FOV), reliance on patient fixation for targeting imaging, and substantial post-processing time. We previously showed an efficient image based eye tracking method for real-time optical stabilization and image registration in AOSLO. However, in patients with poor fixation, eye motion causes the FOV to drift substantially, causing this approach to fail. We solve that problem here by tracking eye motion at multiple spatial scales simultaneously by optically and electronically integrating a wide FOV SLO (WFSLO) with an AOSLO. This multi-scale approach, implemented with fast tip/tilt mirrors, has a large stabilization range of ± 5.6°. Our method consists of three stages implemented in parallel: 1) coarse optical stabilization driven by a WFSLO image, 2) fine optical stabilization driven by an AOSLO image, and 3) sub-pixel digital registration of the AOSLO image. We evaluated system performance in normal eyes and diseased eyes with poor fixation. Residual image motion with incremental compensation after each stage was: 1) ~2-3 arc minutes, (arcmin) 2) ~0.5-0.8 arcmin and, 3) ~0.05-0.07 arcmin, for normal eyes. Performance in eyes with poor fixation was: 1) ~3-5 arcmin, 2) ~0.7-1.1 arcmin and 3) ~0.07-0.14 arcmin. We demonstrate that this system is capable of reducing image motion by a factor of ~400, on average. This new optical design provides additional benefits for clinical imaging, including a steering subsystem for AOSLO that can be guided by the WFSLO to target specific regions of interest such as retinal pathology and real-time averaging of registered images to eliminate image post-processing.

Entities:  

Keywords:  (110.1080) Active or adaptive optics; (120.3890) Medical optics instrumentation; (170.3880) Medical and biological imaging; (170.4470) Ophthalmology; (330.2210) Vision - eye movements

Year:  2015        PMID: 26114033      PMCID: PMC4473748          DOI: 10.1364/BOE.6.002120

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  20 in total

1.  Large-field-of-view, modular, stabilized, adaptive-optics-based scanning laser ophthalmoscope.

Authors:  Stephen A Burns; Remy Tumbar; Ann E Elsner; Daniel Ferguson; Daniel X Hammer
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-05       Impact factor: 2.129

2.  Ultrahigh-resolution optical coherence tomography with monochromatic and chromatic aberration correction.

Authors:  Robert J Zawadzki; Barry Cense; Yan Zhang; Stacey S Choi; Donald T Miller; John S Werner
Journal:  Opt Express       Date:  2008-05-26       Impact factor: 3.894

3.  Closed-loop optical stabilization and digital image registration in adaptive optics scanning light ophthalmoscopy.

Authors:  Qiang Yang; Jie Zhang; Koji Nozato; Kenichi Saito; David R Williams; Austin Roorda; Ethan A Rossi
Journal:  Biomed Opt Express       Date:  2014-08-26       Impact factor: 3.732

4.  Longitudinal study of cone photoreceptors during retinal degeneration and in response to ciliary neurotrophic factor treatment.

Authors:  Katherine E Talcott; Kavitha Ratnam; Sanna M Sundquist; Anna S Lucero; Brandon J Lujan; Weng Tao; Travis C Porco; Austin Roorda; Jacque L Duncan
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-04-06       Impact factor: 4.799

Review 5.  Imaging single cells in the living retina.

Authors:  David R Williams
Journal:  Vision Res       Date:  2011-05-10       Impact factor: 1.886

6.  In vivo imaging of retinal pigment epithelium cells in age related macular degeneration.

Authors:  Ethan A Rossi; Piero Rangel-Fonseca; Keith Parkins; William Fischer; Lisa R Latchney; Margaret A Folwell; David R Williams; Alfredo Dubra; Mina M Chung
Journal:  Biomed Opt Express       Date:  2013-10-18       Impact factor: 3.732

7.  Functional photoreceptor loss revealed with adaptive optics: an alternate cause of color blindness.

Authors:  Joseph Carroll; Maureen Neitz; Heidi Hofer; Jay Neitz; David R Williams
Journal:  Proc Natl Acad Sci U S A       Date:  2004-05-17       Impact factor: 11.205

8.  Microscopic inner retinal hyper-reflective phenotypes in retinal and neurologic disease.

Authors:  Drew Scoles; Brian P Higgins; Robert F Cooper; Adam M Dubis; Phyllis Summerfelt; David V Weinberg; Judy E Kim; Kimberly E Stepien; Joseph Carroll; Alfredo Dubra
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-06-03       Impact factor: 4.799

9.  Reflective afocal broadband adaptive optics scanning ophthalmoscope.

Authors:  Alfredo Dubra; Yusufu Sulai
Journal:  Biomed Opt Express       Date:  2011-05-27       Impact factor: 3.732

10.  Noninvasive imaging of the human rod photoreceptor mosaic using a confocal adaptive optics scanning ophthalmoscope.

Authors:  Alfredo Dubra; Yusufu Sulai; Jennifer L Norris; Robert F Cooper; Adam M Dubis; David R Williams; Joseph Carroll
Journal:  Biomed Opt Express       Date:  2011-06-08       Impact factor: 3.732

View more
  21 in total

1.  Erratum: An adaptive optics imaging system designed for clinical use: publisher's note.

Authors:  Jie Zhang; Qiang Yang; Kenichi Saito; Koji Nozato; Austin Roorda; David R Williams; Ethan A Rossi
Journal:  Biomed Opt Express       Date:  2015-07-10       Impact factor: 3.732

2.  Long eye relief fundus camera and fixation target with partial correction of ocular longitudinal chromatic aberration.

Authors:  Samuel Steven; Yusufu N Sulai; Soon K Cheong; Julie Bentley; Alfredo Dubra
Journal:  Biomed Opt Express       Date:  2018-11-07       Impact factor: 3.732

3.  Imaging individual neurons in the retinal ganglion cell layer of the living eye.

Authors:  Ethan A Rossi; Charles E Granger; Robin Sharma; Qiang Yang; Kenichi Saito; Christina Schwarz; Sarah Walters; Koji Nozato; Jie Zhang; Tomoaki Kawakami; William Fischer; Lisa R Latchney; Jennifer J Hunter; Mina M Chung; David R Williams
Journal:  Proc Natl Acad Sci U S A       Date:  2017-01-03       Impact factor: 11.205

Review 4.  [Technical principles of adaptive optics in ophthalmology].

Authors:  J L Reiniger; N Domdei; F G Holz; W M Harmening
Journal:  Ophthalmologe       Date:  2017-03       Impact factor: 1.059

5.  Label free measurement of retinal blood cell flux, velocity, hematocrit and capillary width in the living mouse eye.

Authors:  A Guevara-Torres; A Joseph; J B Schallek
Journal:  Biomed Opt Express       Date:  2016-09-23       Impact factor: 3.732

6.  Image registration and averaging of low laser power two-photon fluorescence images of mouse retina.

Authors:  Nathan S Alexander; Grazyna Palczewska; Patrycjusz Stremplewski; Maciej Wojtkowski; Timothy S Kern; Krzysztof Palczewski
Journal:  Biomed Opt Express       Date:  2016-06-20       Impact factor: 3.732

Review 7.  Adaptive optics imaging of the human retina.

Authors:  Stephen A Burns; Ann E Elsner; Kaitlyn A Sapoznik; Raymond L Warner; Thomas J Gast
Journal:  Prog Retin Eye Res       Date:  2018-08-27       Impact factor: 21.198

8.  Two-photon imaging of the mammalian retina with ultrafast pulsing laser.

Authors:  Grazyna Palczewska; Patrycjusz Stremplewski; Susie Suh; Nathan Alexander; David Salom; Zhiqian Dong; Daniel Ruminski; Elliot H Choi; Avery E Sears; Timothy S Kern; Maciej Wojtkowski; Krzysztof Palczewski
Journal:  JCI Insight       Date:  2018-09-06

Review 9.  Vision science and adaptive optics, the state of the field.

Authors:  Susana Marcos; John S Werner; Stephen A Burns; William H Merigan; Pablo Artal; David A Atchison; Karen M Hampson; Richard Legras; Linda Lundstrom; Geungyoung Yoon; Joseph Carroll; Stacey S Choi; Nathan Doble; Adam M Dubis; Alfredo Dubra; Ann Elsner; Ravi Jonnal; Donald T Miller; Michel Paques; Hannah E Smithson; Laura K Young; Yuhua Zhang; Melanie Campbell; Jennifer Hunter; Andrew Metha; Grazyna Palczewska; Jesse Schallek; Lawrence C Sincich
Journal:  Vision Res       Date:  2017-02-27       Impact factor: 1.886

10.  Strip-based digital image registration for distortion minimization and robust eye motion measurement from scanned ophthalmic imaging systems.

Authors:  Min Zhang; Elena Gofas-Salas; Bianca T Leonard; Yuhua Rui; Valerie C Snyder; Hope M Reecher; Pedro Mecê; Ethan A Rossi
Journal:  Biomed Opt Express       Date:  2021-03-25       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.