OBJECTIVE: this study sought to test the interexaminer agreement and reliability of 15 indicators of nursing care quality.Entities:
Mesh:
Year: 2014 PMID: 26107830 PMCID: PMC4292599 DOI: 10.1590/0104-1169.3262.2407
Source DB: PubMed Journal: Rev Lat Am Enfermagem ISSN: 0104-1169
Assessment of the interexaminer agreement relative to indicators 1 to 11 and 15 by means of the k statistic, Londrina, PR, Brazil, 2013
| Indicator | N | % agreement | Fleiss k | 95% CI | p-value | Agreement |
|---|---|---|---|---|---|---|
| 01 | 33 | 100 | 1.000 | 0.803-1.000 | <0.001 | Excellent |
| 02 | 25 | 100 | 1.000 | 0.835-1.000 | <0.001 | Excellent |
| 03 | 22 | 100 | 1.000 | 0.852-1.000 | <0.001 | Excellent |
| 04 | 25 | 97 | 0.970 | 0.830-1.000 | <0.001 | Excellent |
| 05a | 10 | 97 | 0.956 | 0.795-1.000 | <0.001 | Excellent |
| 05b | 23 | 94 | 0.969 | 0.829-1.000 | <0.001 | Excellent |
| 05c | 04 | 100 | 1.000 | 0.847-1.000 | <0.001 | Excellent |
| 06a | 10 | 100 | 1.000 | 0.845-1.000 | <0.001 | Excellent |
| 06b | 23 | 97 | 0.969 | 0.829-1.000 | <0.001 | Excellent |
| 06c | 02 | 100 | 1.000 | 0.846-1.000 | <0.001 | Excellent |
| 07 | 09 | 100 | 1.000 | 0.837-1.000 | <0.001 | Excellent |
| 08 | 03 | 100 | 1.000 | 0.803-1.000 | <0.001 | Excellent |
| 09 | 05 | 100 | 1.000 | 0.846-1.000 | <0.001 | Excellent |
| 10 | 05 | 100 | 1.000 | 0.803-1.000 | <0.001 | Excellent |
| 11 | 05 | 100 | 1.000 | 0.846-1.000 | <0.001 | Excellent |
| 15 | 27 | 100 | 1.000 | 0.855-1.000 | <0.001 | Excellent |
Indicators 1 - 11; 15
1. Identification of the patient's bed.
2. Identification of the bed fall risk.
3. Identification of peripheral venous lines.
4. Verification of extravasation skin injuries.
5. a – Identification of intravenous infusion equipment (maintenance fluids).
b – Identification of intravenous infusion equipment (fluids to dilute medications).
c – Identification of intravenous infusion equipment (fluids – drug 1).
6. a – Identification of intravenous infusion flasks – label (maintenance fluids).
b – Identification of intravenous infusion flasks – label (fluids to dilute medications).
c – Identification of intravenous infusion flasks – label (fluids – drug 1).
7. Identification of infusion speed control – graduated scale.
8. Identification of gastric – oro- and nasogastric – tubes for drainage.
9. Indwelling urinary catheter fixation.
10. Position of urine drainage bag, indwelling urinary catheter.
11. Position of the urine drainage bag spigot.
15. Elaboration of complete daily prescription by nurse.
Number of patients for whom indicator assessment applies.
Assessment of the interexaminer agreement relative to indicators 12, 13, and 14 by means of the ICC, Londrina, PR, Brazil, 2013
| Indicator | N | % agreement | ICC | 95% CI | p-value | Reproducibility |
|---|---|---|---|---|---|---|
| 12 - a | 559 | 99.7 | 0.992 | 0.983-0.996 | <0.001 | Excellent |
| 12 - b | 81 | 98.1 | 0.980 | 0.959-0.990 | <0.001 | Excellent |
| 13 - a | 56 | 98.2 | 0.957 | 0.914-0.979 | <0.001 | Excellent |
| 13 - b | 44 | 97.8 | 0.951 | 0.903-0.976 | <0.001 | Excellent |
| 14 - a | 354 | 99.6 | 0.969 | 0.938-0.985 | <0.001 | Excellent |
| 14 - b | 64 | 97.5 | 0.859 | 0.732-0.929 | <0.001 | Excellent |
Indicators 12 - 14
12. a - Checking of nursing prescription procedures (adequate) b - Checking of nursing prescription procedures (inadequate)
13. a - Record of verification of prescribed vital signs (adequate) b - Record of verification of prescribed vital signs (inadequate).
14. a - Checking of nursing procedures in medical prescriptions (adequate) b - Checking of nursing procedures in medical prescriptions (inadequate).