Numerical Analysis of Organ Doses Delivered During Computed Tomography Examinations Using Japanese Adult Phantoms with the WAZA-ARI Dosimetry System.

Fumiaki Takahashi1, Kaoru Sato, Akira Endo, Koji Ono, Nobuhiko Ban, Takayuki Hasegawa, Yasushi Katsunuma, Takayasu Yoshitake, Michiaki Kai.   

Abstract

A dosimetry system for computed tomography (CT) examinations, named WAZA-ARI, is being developed to accurately assess radiation doses to patients in Japan. For dose calculations in WAZA-ARI, organ doses were numerically analyzed using average adult Japanese male (JM) and female (JF) phantoms with the Particle and Heavy Ion Transport code System (PHITS). Experimental studies clarified the photon energy distribution of emitted photons and dose profiles on the table for some multi-detector row CT (MDCT) devices. Numerical analyses using a source model in PHITS could specifically take into account emissions of x rays from the tube to the table with attenuation of photons through a beam-shaping filter for each MDCT device based on the experiment results. The source model was validated by measuring the CT dose index (CTDI). Numerical analyses with PHITS revealed a concordance of organ doses with body sizes of the JM and JF phantoms. The organ doses in the JM phantoms were compared with data obtained using previously developed systems. In addition, the dose calculations in WAZA-ARI were verified with previously reported results by realistic NUBAS phantoms and radiation dose measurement using a physical Japanese model (THRA1 phantom). The results imply that numerical analyses using the Japanese phantoms and specified source models can give reasonable estimates of dose for MDCT devices for typical Japanese adults.

Entities:  

Mesh:

Year:  2015        PMID: 26107430     DOI: 10.1097/HP.0000000000000299

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  2 in total

Review 1.  Medical application of particle and heavy ion transport code system PHITS.

Authors:  Takuya Furuta; Tatsuhiko Sato
Journal:  Radiol Phys Technol       Date:  2021-06-30

2.  Radiation protection in radiological imaging: a survey of imaging modalities used in Japanese institutions for verifying applicator placements in high-dose-rate brachytherapy.

Authors:  Hiroyuki Okamoto; Satoshi Kito; Naoki Tohyama; Shunsuke Yonai; Ryu Kawamorita; Masaru Nakamura; Takahiro Fujimoto; Syoji Tani; Akihiro Yomoda; Toru Isobe; Hiroshi Furukawa; Kikuo Kotaka; Jun Itami; Hitoshi Ikushima; Takushi Dokiya; Yoshiyuki Shioyama
Journal:  J Radiat Res       Date:  2021-01-01       Impact factor: 2.724

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.