Literature DB >> 26092218

Detection and measurement of rheumatoid bone and joint lesions of fingers by tomosynthesis: a phantom study for reconstruction filter setting optimization.

Yohei Ono1, Tamotsu Kamishima2, Nobutoshi Yasojima3, Kenichi Tamura4, Kaori Tsutsumi5.   

Abstract

Rheumatoid arthritis (RA) is a systemic disease that is caused by autoimmunity. RA causes synovial proliferation, which may result in bone erosion and joint space narrowing in the affected joint. Tomosynthesis is a promising modality which may detect early bone lesions such as small bone erosion and slight joint space narrowing. Nevertheless, so far, the optimal reconstruction filter for detection of early bone lesions of fingers on tomosynthesis has not yet been known. Our purpose in this study was to determine an optimal reconstruction filter setting by using a bone phantom. We obtained images of a cylindrical phantom with holes simulating bone erosions (diameters of 0.6, 0.8, 1.0, 1.2, and 1.4 mm) and joint spaces by aligning two phantoms (space widths from 0.5 to 5.0 mm with 0.5 mm intervals), examining six reconstruction filters by using tomosynthesis. We carried out an accuracy test of the bone erosion size and joint space width, done by one radiological technologist, and a test to assess the visibility of bone erosion, done by five radiological technologists. No statistically significant difference was observed in the measured bone erosion size and joint space width among all of the reconstruction filters. In the visibility assessment test, reconstruction filters of Thickness+- and Thickness-- were among the best statistically in all characteristics except the signal-to-noise ratio. The Thickness+- and Thickness-- reconstruction filter may be optimal for evaluation of RA bone lesions of small joints in tomosynthesis.

Entities:  

Keywords:  Bone erosion; Bone phantom; Joint space narrowing; Reconstruction filter; Tomosynthesis

Mesh:

Year:  2015        PMID: 26092218     DOI: 10.1007/s12194-015-0327-0

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  16 in total

1.  How to read radiographs according to the Sharp/van der Heijde method.

Authors:  D van der Heijde
Journal:  J Rheumatol       Date:  2000-01       Impact factor: 4.666

Review 2.  Digital x-ray tomosynthesis: current state of the art and clinical potential.

Authors:  James T Dobbins; Devon J Godfrey
Journal:  Phys Med Biol       Date:  2003-10-07       Impact factor: 3.609

Review 3.  Rheumatoid arthritis: a practical guide to state-of-the-art imaging, image interpretation, and clinical implications.

Authors:  Oliver J Sommer; Andrea Kladosek; Volkmar Weiler; Heinz Czembirek; Martina Boeck; Michael Stiskal
Journal:  Radiographics       Date:  2005 Mar-Apr       Impact factor: 5.333

4.  Use of tomosynthesis for erosion evaluation in rheumatoid arthritic hands and wrists.

Authors:  Clarissa Canella; Peggy Philippe; Vittorio Pansini; Julia Salleron; René-Marc Flipo; Anne Cotten
Journal:  Radiology       Date:  2010-11-02       Impact factor: 11.105

5.  Evidence of significant radiographic damage in rheumatoid arthritis within the first 2 years of disease.

Authors:  H A Fuchs; J J Kaye; L F Callahan; E P Nance; T Pincus
Journal:  J Rheumatol       Date:  1989-05       Impact factor: 4.666

6.  Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases.

Authors:  Jenny Vikgren; Sara Zachrisson; Angelica Svalkvist; Ase A Johnsson; Marianne Boijsen; Agneta Flinck; Susanne Kheddache; Magnus Båth
Journal:  Radiology       Date:  2008-10-10       Impact factor: 11.105

Review 7.  Joint erosions and patients with early rheumatoid arthritis.

Authors:  D M van der Heijde
Journal:  Br J Rheumatol       Date:  1995-11

8.  Digital tomosynthesis of the chest: comparison of patient exposure dose and image quality between standard default setting and low dose setting.

Authors:  Hye Sun Hwang; Myung Jin Chung; Kyung Soo Lee
Journal:  Korean J Radiol       Date:  2013-05-02       Impact factor: 3.500

9.  Determination of dosimetric quantities in pediatric abdominal computed tomography scans.

Authors:  Tiago da Silva Jornada; Teógenes Augusto da Silva
Journal:  Radiol Bras       Date:  2014 Sep-Oct

10.  Is There Any Relationship between Joint Destruction and Carotid Intima-media Thickness in Patients with Rheumatoid Arthritis?

Authors:  Ahmet Tutoğlu; Ahmet Boyaci; Nurefsan Boyaci; Zekeriya Kaya; Rifat Aridici; Irfan Koca
Journal:  J Phys Ther Sci       Date:  2014-07-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.