Literature DB >> 26091856

Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: A systematic review and meta-analysis.

Muhammad R Afzal1, Jawaria Chatta1, Anweshan Samanta1, Salman Waheed1, Morteza Mahmoudi1, Rachel Vukas1, Sampath Gunda1, Madhu Reddy1, Buddhadeb Dawn1, Dhanunjaya Lakkireddy2.   

Abstract

The suboptimal outcomes of atrial fibrillation (AF) ablation have been attributed to lack of transmural lesions during pulmonary vein isolation. The advent of contact force (CF) sensing technology enables real-time assessment of the applied force at the catheter-tissue interface and increases the chances of transmural lesions. We sought to perform a meta-analysis of data from eligible studies to delineate the true impact of CF technology. Database searches through April 2015 identified 9 eligible studies (enrolling 1148 patients). The relative risk of AF recurrence at follow-up was used as the primary end point and assessed with random-effects meta-analysis. Radiofrequency (RF) duration, total procedure length, and fluoroscopy exposure were assessed as secondary outcomes using weighted mean difference with the random-effects model. Compared with standard technology, the use of CF technology showed a 37% reduction (relative risk 0.63; 95% confidence interval 0.44-0.91; P = .01) in AF recurrence at a median follow-up of 12 months and a 7.3-minute reduction (95% confidence interval -14.05 to -0.55; P = .03) in RF use during ablation. There was no significant difference in total procedure length and fluoroscopy exposure between the 2 groups. In conclusion, this meta-analysis shows that the use of CF technology decreases AF recurrence at a median follow-up of 12 months and also led to decreased use of RF during ablation. There was no difference in total procedure length and fluoroscopy exposure.
Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Atrial fibrillation; Contact force sensing technology; Meta-analysis; Pulmonary vein isolation; Radiofrequency ablation

Mesh:

Year:  2015        PMID: 26091856     DOI: 10.1016/j.hrthm.2015.06.026

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  25 in total

1.  Novel Interventional Strategies for the Treatment of Atrial Fibrillation.

Authors:  Konstantinos C Siontis; Hakan Oral
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-05

2.  Pursuing early catheter ablation to treat atrial fibrillation in the congestive heart failure population: significance of the AATAC trial results.

Authors:  Karen P Phillips
Journal:  J Thorac Dis       Date:  2016-08       Impact factor: 2.895

3.  Contact force facilitates the achievement of an unexcitable ablation line during pulmonary vein isolation.

Authors:  Benjamin Schaeffer; Stephan Willems; Christian Meyer; Jakob Lüker; Ruken Ö Akbulak; Julia Moser; Mario Jularic; Christian Eickholt; Jana M Schwarzl; Melanie Gunawardene; Pawel Kuklik; Arian Sultan; Boris A Hoffmann; Daniel Steven
Journal:  Clin Res Cardiol       Date:  2018-03-02       Impact factor: 5.460

4.  Evolution of Force Sensing Technologies.

Authors:  Dipen Shah
Journal:  Arrhythm Electrophysiol Rev       Date:  2017-06

5.  Increasing the Single-Procedure Success Rate of Pulmonary Vein Isolation.

Authors:  Mattias Duytschaever; Mark O'Neill; Martin Martinek
Journal:  Arrhythm Electrophysiol Rev       Date:  2017-12

6.  Achieving Bidirectional Long Delays In Pulmonary Vein Antral Lines Prior To Bidirectional Block In Patients With Paroxysmal Atrial Fibrillation (The Bi-Bi Technique For Atrial Fibrillation Ablation).

Authors:  Adel F Mina; Nicholas L Warnecke
Journal:  J Atr Fibrillation       Date:  2016-08-31

Review 7.  Economic Evaluation of Catheter Ablation Versus Medical Therapy for the Treatment of Atrial Fibrillation from the Perspective of the UK.

Authors:  Lisa Wm Leung; Zaki Akhtar; Christos Kontogiannis; Ryan J Imhoff; Hannah Taylor; Mark M Gallagher
Journal:  Arrhythm Electrophysiol Rev       Date:  2022-04

8.  Catheter Ablation of Atrial Fibrillation: Advent of Second-Generation Technologies.

Authors:  Eric Buch; Kalyanam Shivkumar
Journal:  J Am Coll Cardiol       Date:  2015-09-22       Impact factor: 24.094

9.  Optimizing Durability in Radiofrequency Ablation of Atrial Fibrillation.

Authors:  Zain I Sharif; E Kevin Heist
Journal:  J Innov Card Rhythm Manag       Date:  2021-05-15

Review 10.  Paroxysmal atrial fibrillation ablation: Achieving permanent pulmonary vein isolation by point-by-point radiofrequency lesions.

Authors:  Alonso Pedrote; Juan Acosta; Beatriz Jáuregui-Garrido; Manuel Frutos-López; Eduardo Arana-Rueda
Journal:  World J Cardiol       Date:  2017-03-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.