Literature DB >> 26091212

Revision of Failed Hip Resurfacing and Large Metal-on-Metal Total Hip Arthroplasty Using Dual-Mobility Components.

Nimrod Snir, Brian K Park, Garret Garofolo, Scott E Marwin.   

Abstract

Revision of metal-on-metal (MoM) total hip arthroplasty (THA) or hip resurfacing is associated with high complication rates. The authors propose dual-mobility components as a surgical option and present short- to mid-term results of MoM hips revised with dual-mobility components. Eighteen consecutive hips that underwent revision of MoM THA or hip resurfacing using dual-mobility components were identified. At final follow-up (mean, 17.5 months), the visual analog scale, modified Harris Hip Score, and SF-12 scores had all improved (P<.05, P<.01, and P<.05, respectively). There were no dislocations or other complications. Revision of failed MoM THA or hip resurfacing using a dual-mobility device is an effective strategy. Copyright 2015, SLACK Incorporated.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26091212     DOI: 10.3928/01477447-20150603-04

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  7 in total

Review 1.  The evolution of outcomes and indications for the dual-mobility cup: a systematic review.

Authors:  Cécile Batailler; Camdon Fary; Régis Verdier; Thierry Aslanian; Jacques Caton; Sebastien Lustig
Journal:  Int Orthop       Date:  2016-12-21       Impact factor: 3.075

2.  CORR Insights®: Outcomes After Metal-on-metal Hip Revision Surgery Depend on the Reason for Failure: A Propensity Score-matched Study.

Authors:  Kodali Siva R K Prasad
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

3.  Can Dislocation of a Constrained Liner Be Salvaged With Dual-mobility Constructs in Revision THA?

Authors:  Brian P Chalmers; Graham D Pallante; Michael J Taunton; Rafael J Sierra; Robert T Trousdale
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

4.  Revision of Metal-on-metal Hip Arthroplasty with Well Fixed and Positioned Acetabular Component Using a Dual-mobility Head and Review of Literature.

Authors:  Guillem Figueras; Ramón Vives Planell; Ramón Serra Fernàndez; Joan Camí Biayna
Journal:  Open Orthop J       Date:  2016-10-31

5.  Cementation of a monoblock dual mobility bearing in a newly implanted porous revision acetabular component in patients undergoing revision total hip arthroplasty.

Authors:  Jonathan A Gabor; James E Feng; Shashank Gupta; Tyler E Calkins; Craig J Della Valle; Jonathan Vigdorchik; Ran Schwarzkopf
Journal:  Arthroplast Today       Date:  2019-06-14

Review 6.  Revision of a Monoblock Metal-on-Metal Cup Using a Dual Mobility Component: Is It a Reasonable Option?

Authors:  Saverio Affatato; Emanuela Castiello; Luca Amendola; Saverio Comitini; Jean Louis Prudhon; Domenico Tigani
Journal:  Materials (Basel)       Date:  2020-04-27       Impact factor: 3.623

7.  Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis.

Authors:  Fu-Yuan Pai; Hsuan-Hsiao Ma; Te-Feng Arthur Chou; Tsan-Wen Huang; Kuo-Chin Huang; Shang-Wen Tsai; Cheng-Fong Chen; Wei-Ming Chen
Journal:  BMC Musculoskelet Disord       Date:  2021-06-14       Impact factor: 2.362

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.