Literature DB >> 26083863

A framework for automated contour quality assurance in radiation therapy including adaptive techniques.

M B Altman1, J A Kavanaugh, H O Wooten, O L Green, T A DeWees, H Gay, W L Thorstad, H Li, S Mutic.   

Abstract

Contouring of targets and normal tissues is one of the largest sources of variability in radiation therapy treatment plans. Contours thus require a time intensive and error-prone quality assurance (QA) evaluation, limitations which also impair the facilitation of adaptive radiotherapy (ART). Here, an automated system for contour QA is developed using historical data (the 'knowledge base'). A pilot study was performed with a knowledge base derived from 9 contours each from 29 head-and-neck treatment plans. Size, shape, relative position, and other clinically-relevant metrics and heuristically derived rules are determined. Metrics are extracted from input patient data and compared against rules determined from the knowledge base; a computer-learning component allows metrics to evolve with more input data, including patient specific data for ART. Nine additional plans containing 42 unique contouring errors were analyzed. 40/42 errors were detected as were 9 false positives. The results of this study imply knowledge-based contour QA could potentially enhance the safety and effectiveness of RT treatment plans as well as increase the efficiency of the treatment planning process, reducing labor and the cost of therapy for patients.

Entities:  

Mesh:

Year:  2015        PMID: 26083863     DOI: 10.1088/0031-9155/60/13/5199

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

Review 1.  Automation in intensity modulated radiotherapy treatment planning-a review of recent innovations.

Authors:  Mohammad Hussein; Ben J M Heijmen; Dirk Verellen; Andrew Nisbet
Journal:  Br J Radiol       Date:  2018-09-04       Impact factor: 3.039

Review 2.  Automated Plan Checking Software Demonstrates Continuous and Sustained Improvements in Safety and Quality: A 3-year Longitudinal Analysis.

Authors:  Delaney Stuhr; Ying Zhou; Hai Pham; Jian-Ping Xiong; Shi Liu; James G Mechalakos; Sean L Berry
Journal:  Pract Radiat Oncol       Date:  2021-10-17

3.  Impact of random outliers in auto-segmented targets on radiotherapy treatment plans for glioblastoma.

Authors:  Robert Poel; Elias Rüfenacht; Ekin Ermis; Michael Müller; Michael K Fix; Daniel M Aebersold; Peter Manser; Mauricio Reyes
Journal:  Radiat Oncol       Date:  2022-10-22       Impact factor: 4.309

4.  A web-based brain metastases segmentation and labeling platform for stereotactic radiosurgery.

Authors:  Zi Yang; Hui Liu; Yan Liu; Strahinja Stojadinovic; Robert Timmerman; Lucien Nedzi; Tu Dan; Zabi Wardak; Weiguo Lu; Xuejun Gu
Journal:  Med Phys       Date:  2020-05-23       Impact factor: 4.071

5.  Strategies for effective physics plan and chart review in radiation therapy: Report of AAPM Task Group 275.

Authors:  Eric Ford; Leigh Conroy; Lei Dong; Luis Fong de Los Santos; Anne Greener; Grace Gwe-Ya Kim; Jennifer Johnson; Perry Johnson; James G Mechalakos; Brian Napolitano; Stephanie Parker; Deborah Schofield; Koren Smith; Ellen Yorke; Michelle Wells
Journal:  Med Phys       Date:  2020-04-15       Impact factor: 4.071

6.  Dosimetric effect of the intestinal gas of online adaptive stereotactic body radiotherapy on target and critical organs without online electron density correction for pancreatic cancer.

Authors:  Chen Su; Hiroyuki Okamoto; Shie Nishioka; Tatsuya Sakasai; Daisuke Fujiyama; Yuki Miura; Yuki Tsunoda; Junichi Kuwahara; Satoshi Nakamura; Kotaro Iijima; Takahito Chiba; Keita Kaga; Mihiro Takemori; Hiroki Nakayama; Shouichi Katsuta; Koji Inaba; Hiroshi Igaki; Yuko Nakayama; Jun Itami
Journal:  Br J Radiol       Date:  2021-02-05       Impact factor: 3.039

7.  Using failure mode and effects analysis (FMEA) to generate an initial plan check checklist for improved safety in radiation treatment.

Authors:  Prema Rassiah; Fan-Chi Frances Su; Y Jessica Huang; Dan Spitznagel; Vikren Sarkar; Martin W Szegedi; Hui Zhao; Adam B Paxton; Geoff Nelson; Bill J Salter
Journal:  J Appl Clin Med Phys       Date:  2020-06-25       Impact factor: 2.102

8.  Multichannel Film Dosimetry for Quality Assurance of Intensity Modulated Radiotherapy Treatment Plans Under 0.35 T Magnetic Field.

Authors:  Gorkem Gungor; Latif Korkmaz; Namik Kayalilar; Gokhan Aydin; Bulent Yapici; Teuta Zoto Mustafayev; Banu Atalar; Enis Ozyar
Journal:  Cureus       Date:  2020-03-20

9.  Automated Quality Assurance of OAR Contouring for Lung Cancer Based on Segmentation With Deep Active Learning.

Authors:  Kuo Men; Huaizhi Geng; Tithi Biswas; Zhongxing Liao; Ying Xiao
Journal:  Front Oncol       Date:  2020-07-03       Impact factor: 6.244

10.  Stereotactic MR-Guided Online Adaptive Radiation Therapy (SMART) for Ultracentral Thorax Malignancies: Results of a Phase 1 Trial.

Authors:  Lauren E Henke; Jeffrey R Olsen; Jessika A Contreras; Austen Curcuru; Todd A DeWees; Olga L Green; Jeff Michalski; Sasa Mutic; Michael C Roach; Jeffrey D Bradley; Parag J Parikh; Rojano Kashani; Clifford G Robinson
Journal:  Adv Radiat Oncol       Date:  2018-10-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.