Literature DB >> 26079490

High Signal Intensity in Globus Pallidus and Dentate Nucleus on Unenhanced T1-weighted MR Images: Evaluation of Two Linear Gadolinium-based Contrast Agents.

Joana Ramalho1, Mauricio Castillo1, Mamdoh AlObaidy1, Renato H Nunes1, Miguel Ramalho1, Brian M Dale1, Richard C Semelka1.   

Abstract

PURPOSE: To determine if a correlation exists between the number of previous enhanced magnetic resonance (MR) imaging examinations and high signal intensity in the globus pallidus (GP) and dentate nucleus (DN) in patients who received gadodiamide (Omniscan), a linear nonionic gadolinium-based contrast agent, and in those who received gadobenate dimeglumine (MultiHance), a linear ionic contrast agent.
MATERIALS AND METHODS: Institutional review board approval was obtained for this single-center retrospective study, with waiver of informed consent. The study population included 69 patients divided into two groups: Group 1 included patients who underwent gadodiamide-enhanced MR imaging, and group 2 included patients who underwent gadobenate dimeglumine-enhanced MR imaging. Two radiologists conducted a quantitative analysis of unenhanced T1-weighted images by using region of interest measurements. The GP-to-thalamus (TH) signal intensity ratio, DN-to-middle cerebellar peduncle (MCP) signal intensity ratio and relative percentage change (Rchange) between the first and last examinations for each patient were calculated. Relation between the signal intensity ratios and Rchange and the number of enhanced MR imaging examinations was analyzed by using a generalized additive model. Inter- and intraobserver agreement was evaluated with the Lin concordance correlation coefficient test.
RESULTS: Group 1 included 23 patients (19 female), with a mean of 5.0 doses ± 2.4 (standard deviation) (range, 3-11 doses) administered. Group 2 included 46 patients (24 female) with a mean of 4.6 doses ± 2.2 (range, 3-11 doses) administered. The interval between the first and last examination was 1500.1 days ± 780.2 (range, 98-3097 days) for group 1 and 1086.2 days ± 582.9 (range, 94-2633) for group 2. All patients had normal liver and renal function. Gadodiamide showed a significant increase in DN:MCP and GP:TH (P < .001 for both) and in Rchange (P = .001 for GP:TH, P < .001 for DN:MCP). In group 2, there was no significant increase in DN:MCP or GP:TH over time or in Rchange for GP:TH, but there was a significant trend toward an increase in Rchange for DN:MCP (P = .013). Interobserver agreement was almost perfect (0.99; 95% confidence interval: 0.99, 0.99) for all evaluated structures. Intraobserver agreement was substantial to almost perfect for both readers.
CONCLUSION: A significant increase in GP:TH and DN:MCP is associated with multiple gadodiamide-enhanced studies but not with gadobenate dimeglumine-enhanced studies, likely reflecting differences in stability and elimination of both contrast agents. Rate-of-change data indirectly suggest gadolinium deposition in the DN with gadobenate dimeglumine use, although it is considerably less than that with gadodiamide use.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26079490     DOI: 10.1148/radiol.2015150872

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  68 in total

Review 1.  Gadolinium-based contrast agents: did we miss something in the last 25 years?

Authors:  Bruno Beomonte Zobel; Carlo Cosimo Quattrocchi; Yuri Errante; Rosario Francesco Grasso
Journal:  Radiol Med       Date:  2015-12-26       Impact factor: 3.469

2.  Gadolinium deposition in the brain: association with various GBCAs using a generalized additive model.

Authors:  Sohi Bae; Ho-Joon Lee; Kyunghwa Han; Yae-Won Park; Yoon Seong Choi; Sung Soo Ahn; Jinna Kim; Seung-Koo Lee
Journal:  Eur Radiol       Date:  2017-01-12       Impact factor: 5.315

3.  Signal intensity change on unenhanced T1-weighted images in dentate nucleus following gadobenate dimeglumine in patients with and without previous multiple administrations of gadodiamide.

Authors:  Joana Ramalho; Richard C Semelka; Mamdoh AlObaidy; Miguel Ramalho; Renato H Nunes; Mauricio Castillo
Journal:  Eur Radiol       Date:  2016-02-24       Impact factor: 5.315

4.  Non-contrast myocardial infarct scar assessment using a hybrid native T1 and magnetization transfer imaging sequence at 1.5T.

Authors:  Chong Duan; Yanjie Zhu; Jihye Jang; Jennifer Rodriguez; Ulf Neisius; Ahmed S Fahmy; Reza Nezafat
Journal:  Magn Reson Med       Date:  2018-12-18       Impact factor: 4.668

5.  Effects of serial macrocyclic-based contrast materials gadoterate meglumine and gadobutrol administrations on gadolinium-related dentate nuclei signal increases in unenhanced T1-weighted brain: a retrospective study in 158 multiple sclerosis (MS) patients.

Authors:  Alessandra Splendiani; Marco Perri; Claudia Marsecano; Valentina Vellucci; Giulia Michelini; Antonio Barile; Ernesto Di Cesare
Journal:  Radiol Med       Date:  2017-09-27       Impact factor: 3.469

6.  Signal intensity increases in dentate nucleus/globus pallidus/pulvinar on unenhanced T1WI MR images after multiple examinations with gadodiamide.

Authors:  Takao Koiso; Masaaki Yamamoto; Shinya Watanabe; Bierta E Barfod
Journal:  Neuroradiol J       Date:  2019-03-29

Review 7.  Gadolinium-based contrast agents: why nephrologists need to be concerned.

Authors:  Katarina Leyba; Brent Wagner
Journal:  Curr Opin Nephrol Hypertens       Date:  2019-03       Impact factor: 2.894

Review 8.  Distribution and chemical forms of gadolinium in the brain: a review.

Authors:  Tomonori Kanda; Yudai Nakai; Akifumi Hagiwara; Hiroshi Oba; Keiko Toyoda; Shigeru Furui
Journal:  Br J Radiol       Date:  2017-09-28       Impact factor: 3.039

Review 9.  Pediatric brain MRI part 1: basic techniques.

Authors:  Mai-Lan Ho; Norbert G Campeau; Thang D Ngo; Unni K Udayasankar; Kirk M Welker
Journal:  Pediatr Radiol       Date:  2017-04-13

Review 10.  Gadolinium-based contrast agents in children.

Authors:  Michael N Rozenfeld; Daniel J Podberesky
Journal:  Pediatr Radiol       Date:  2018-08-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.