Literature DB >> 26071472

Temperature-Sensitive Indicators for Monitoring RBC Concentrates Out of Controlled Temperature Storage.

Joerg P Sigle1, Andreas Holbro2, Thomas Lehmann3, Laura Infanti2, Sabine Gerull3, Martin Stern3, Andre Tichelli3, Jakob Passweg3, Andreas Buser2.   

Abstract

OBJECTIVES: The 30-minute rule for RBC concentrates out of controlled temperature storage does not take into account multiple parameters that influence warming of RBC concentrates. This study evaluated two temperature-sensitive indicators (TIs) for monitoring RBC concentrates during transport.
METHODS: TI labels (Check-Spot [Harald H. Temmel KG, Gleisdorf, Austria] and Thermoindikator V4 [BASF, Basel, Switzerland]) were attached to RBC concentrates prior to delivery. Duration of transport, ambient temperatures, and label results (valid vs expired) were recorded. We evaluated the proportion of labels discrepant to the 30-minute rule overall and among deliveries 30 minutes or less and more than 30 minutes and compared the rates of valid and expired readings between both TIs.
RESULTS: In total, 201 RBC concentrate deliveries (86.6%) lasted 30 minutes or less, and 31 (13.4%) were more than 30 minutes. Forty-six (19.8%) Check-Spot and 37 (15.9%) Thermoindikator V4 results were discrepant to the 30-minute rule. Sixteen (51.6%) and 27 (87.1%) RBC concentrate deliveries more than 30 minutes displayed valid label readings with Check-Spot and Thermoindikator V4, respectively. Rates of expired labels among deliveries 30 minutes or less and valid labels among deliveries more than 30 minutes differed significantly between TIs (P < .01).
CONCLUSIONS: TIs identified a considerable number of RBC concentrates whose temperatures may not be adequately reflected by the 30-minute rule. Variability of readings between TIs stresses the necessity of validation prior to implementation. Copyright© by the American Society for Clinical Pathology.

Keywords:  30-minute rule; RBC concentrates; Temperature-sensitive indicators

Mesh:

Substances:

Year:  2015        PMID: 26071472     DOI: 10.1309/AJCPN7L9RTTPNNRW

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  2 in total

1.  Monitoring of Storage and Transportation Temperature Conditions in Red Blood Cell Units: A Cross-Sectional Study.

Authors:  Shokoufeh Aalaei; Shahram Amini; Mohammad Reza Keramati; Hadi Shahraki; Saeid Eslami
Journal:  Indian J Hematol Blood Transfus       Date:  2018-11-12       Impact factor: 0.900

2.  Questionnaire Survey on Current Red Blood Cell Transport and Storage in Korea for Reducing Wastage.

Authors:  Mikyoung Park; Mina Hur; Hahah Kim; Kyungmi Oh; Hyunmi Kim; Young Hye Song; Dae-Hyun Ko; Yousun Chung
Journal:  Ann Lab Med       Date:  2022-05-01       Impact factor: 3.464

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.