Literature DB >> 30988568

Monitoring of Storage and Transportation Temperature Conditions in Red Blood Cell Units: A Cross-Sectional Study.

Shokoufeh Aalaei1, Shahram Amini2, Mohammad Reza Keramati3, Hadi Shahraki4, Saeid Eslami5,6,7.   

Abstract

The process of storage and transportation of the red blood cells (RBCs) out of the standard temperature range lead to some biochemical reactions. Infusing inappropriately stored RBCs may cause severe complications. The main objective of this study was to investigate the RBC bags' temperature during the transfusion chain including storage, transportation, and transfusion. A cross-sectional study was performed on 100 RBC bags that were sent from the blood bank to the cardiac surgical intensive care unit (CSICU) and the operating room (OR). To record the temperature of RBCs, a temperature monitoring device was attached to each bag of RBCs that were transported from the blood bank to the CSICU and the OR. The stored temperature samples in the devices related to different stages were separated. Finally, the normal and non-normal samples of each phase were segregated based on the current guidelines. The results indicated that 10% of 121,262 recorded temperatures samples (per 2 min) were out of the standard range. Of these, 65, 17, 13, and 5% of samples were related to the blood bank, the OR, transportation, and the CSICU, respectively. The minimum and maximum temperatures were 0 °C and 19.5 °C that were below and above the standard, respectively. In the light of findings of the present study, different stages of blood transportation and storage suffer a number of shortcomings, which are more evident in the blood bank. Thus, it is recommended to better manage blood transfusion chain from the blood bank to hospital wards so as to avoid the inadvertent and undesirable consequences of blood transfusion. Because various judgments made by the personnel about the status of blood bags are subjective, a temperature monitoring device can be employed to better monitor the blood transfusion process and compensate for the errors unnoticed by the personnel.

Keywords:  Blood quality; Inappropriate temperature; Red blood cell; Transfusion

Year:  2018        PMID: 30988568      PMCID: PMC6439098          DOI: 10.1007/s12288-018-1038-6

Source DB:  PubMed          Journal:  Indian J Hematol Blood Transfus        ISSN: 0971-4502            Impact factor:   0.900


  26 in total

Review 1.  Computer-based guideline implementation systems: a systematic review of functionality and effectiveness.

Authors:  R N Shiffman; Y Liaw; C A Brandt; G J Corb
Journal:  J Am Med Inform Assoc       Date:  1999 Mar-Apr       Impact factor: 4.497

Review 2.  Core temperature measurement: methods and current insights.

Authors:  Daniel S Moran; Liran Mendal
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

3.  Blood transportation for medical retrieval services.

Authors:  Peter H Sharley; Ian Williams; Sophia Hague
Journal:  Air Med J       Date:  2003 Nov-Dec

4.  Blood wastage reduction using Lean Sigma methodology.

Authors:  Eugenie S Heitmiller; Richard B Hill; Christi E Marshall; Barbara J Parsons; Lauren C Berkow; Christine A Barrasso; Elizabeth K Zink; Paul M Ness
Journal:  Transfusion       Date:  2010-09       Impact factor: 3.157

5.  Temperature-sensitive labels for containers of RBCs.

Authors:  Viviana Johnson; Albert Langeberg; Addisalem Taye-Makuria; S Gerald Sandler
Journal:  Am J Clin Pathol       Date:  2006-09       Impact factor: 2.493

6.  Core temperature changes in resuspended red blood cells (RBCs) and pediatric RBCs removed from refrigerated storage.

Authors:  Holly Elizabeth Perry; Priyanka Prasad; Susy Kirwan; Yuan Qing Huang
Journal:  Transfusion       Date:  2009-09-22       Impact factor: 3.157

7.  ISO 15189 accreditation: Requirements for quality and competence of medical laboratories, experience of a laboratory I.

Authors:  Omer Guzel; Ebru Ilhan Guner
Journal:  Clin Biochem       Date:  2009-03       Impact factor: 3.281

Review 8.  Improving clinical practice using clinical decision support systems: a systematic review of trials to identify features critical to success.

Authors:  Kensaku Kawamoto; Caitlin A Houlihan; E Andrew Balas; David F Lobach
Journal:  BMJ       Date:  2005-03-14

9.  Improving preventive care by prompting physicians.

Authors:  E A Balas; S Weingarten; C T Garb; D Blumenthal; S A Boren; G D Brown
Journal:  Arch Intern Med       Date:  2000-02-14

10.  Validity of devices that assess body temperature during outdoor exercise in the heat.

Authors:  Douglas J Casa; Shannon M Becker; Matthew S Ganio; Christopher M Brown; Susan W Yeargin; Melissa W Roti; Jason Siegler; Julie A Blowers; Neal R Glaviano; Robert A Huggins; Lawrence E Armstrong; Carl M Maresh
Journal:  J Athl Train       Date:  2007 Jul-Sep       Impact factor: 2.860

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.