| Literature DB >> 26065396 |
Milou H Martens1,2,3, Doenja M J Lambregts1, Nickolas Papanikolaou4, Styliani Alefantinou4, Monique Maas1, Georgios C Manikis5, Kostantinos Marias5, Robert G Riedl6, Geerard L Beets2,3, Regina G H Beets-Tan7,8.
Abstract
PURPOSE: Single-slice magnetization transfer (MT) imaging has shown promising results for evaluating post-radiation fibrosis. The study aim was to evaluate the value of multislice MT imaging to assess tumour response after chemoradiotherapy by comparing magnetization transfer ratios (MTR) with histopathological tumour regression grade (TRG).Entities:
Keywords: Interobserver agreement; Magnetization transfer imaging; Rectal cancer; Response assessment; Tumour regression grade
Mesh:
Year: 2015 PMID: 26065396 PMCID: PMC4712249 DOI: 10.1007/s00330-015-3856-3
Source DB: PubMed Journal: Eur Radiol ISSN: 0938-7994 Impact factor: 5.315
Fig. 1a Axial T2-weighted MRI at primary staging, with ‘T’ indicating the primary tumour. b Axial restaging T2-weighted MRI performed 8 weeks after chemoradiation, and c corresponding axial MTR map showing delineation of the tumour remnant
Fig. 2CONSORT diagram of patient recruitment and reasons for exclusion
Intraclass correlation coefficients for the mean MTR and the histogram parameters measured after chemoradiation
| Intraclass correlation | |
|---|---|
| Mean MTR | |
| Mean | 0.50 |
| Histogram parameters | |
| Min | 0.12 |
| Max | 0.80 |
| Median | 0.55 |
| SD | 0.53 |
| Skewness | 0.29 |
| Kurtosis | 0.36 |
| 5th percentile | 0.29 |
| 30th percentile | 0.45 |
| 70th percentile | 0.64 |
| 95th percentile | 0.80 |
Fig. 3Interobserver reproducibility for mean MTR measurements (a) and 95th percentile MTR (b). Bland-Altman plot of the averaged measurement of the two readers (x-axis) plotted against the difference in measurement between the two readers (y-axis). The continuous line represents the mean absolute difference (bias) between the two readers; the dashed lines represent the 95 % confidence intervals of the mean difference (limits of agreement)
Fig. 4Boxplot showing the distribution of mean MTR values between the different TRG subgroups. MTR values were averaged between the two readers
Results from the receiver operator characteristic curve analyses for histogram parameters individually and in various combinations for in differentiating TRG1–2 from TRG3–5
| Reader 1 | Reader 2 | |||
|---|---|---|---|---|
| AUC | 95 % CI | AUC | 95 % CI | |
| Mean MTR | ||||
| Mean | 0.65 | 0.45–0.85 | 0.87 | 0.75–1.00 |
| Histogram parameters | ||||
| Min | 0.67 | 0.47–0.87 | 0.72 | 0.53–0.91 |
| Max | 0.67 | 0.45–0.88 | 0.58 | 0.37–0.80 |
| Median | 0.62 | 0.41–0.83 | 0.86 | 0.72–0.99 |
| SD | 0.62 | 0.41–0.82 | 0.66 | 0.46–0.85 |
| Skewness | 0.72 | 0.54–0.91 | 0.58 | 0.37–0.78 |
| Kurtosis | 0.70 | 0.51–0.89 | 0.65 | 0.44–0.86 |
| 5th percentile | 0.50 | 0.28–0.72 | 0.65 | 0.45–0.85 |
| 30th percentile | 0.55 | 0.34–0.77 | 0.81 | 0.66–0.97 |
| 70th percentile | 0.68 | 0.48–0.87 | 0.88 | 0.76–1.00 |
| 95th percentile | 0.75 | 0.56–0.94 | 0.88 | 0.76–1.00 |
| Combined parameters | ||||
| Mean + skewness | 0.72 | 0.54–0.91 | 0.87 | 0.75–1.00 |
| Mean + 95th percentile | 0.75 | 0.56–0.94 | 0.90 | 0.78–1.00 |
| Skewness + 95th percentile | 0.81 | 0.65–0.97 | 0.89 | 0.77–1.00 |
| Mean + skewness + 95th percentile | 0.79 | 0.63–0.95 | 0.90 | 0.78–1.00 |
Diagnostic accuracy of MTR parameters
| Parameter | Reader | AUC | Cut-off | Sensitivity | Specificity | PPV | NPV | Overall accuracy |
|---|---|---|---|---|---|---|---|---|
| 95th percentile | Reader 1 | 0.75 | 72.9 % | 70.6 | 84.6 | 68.8 | 85.1 | 76.7 |
| Reader 2 | 0.88 | 74.0 % | 70.6 | 84.6 | 68.8 | 85.7 | 76.7 | |
| Mean + 95th percentile | Reader 1 | 0.75 | −0.14 | 70.6 | 92.3 | 70.6 | 92.3 | 80.0 |
| Reader 2 | 0.90 | −0.06 | 76.5 | 84.6 | 73.3 | 86.7 | 80.0 | |
| Skewness + 95th percentile | Reader 1 | 0.81 | −0.20 | 76.5 | 84.6 | 73.3 | 86.7 | 80.0 |
| Reader 2 | 0.89 | −0.06 | 76.5 | 84.6 | 73.3 | 86.7 | 80.0 | |
| Mean + skewness + 95th percentile | Reader 1 | 0.79 | −0.19 | 70.6 | 76.9 | 66.7 | 80.0 | 73.3 |
| Reader 2 | 0.90 | −0.06 | 76.5 | 84.6 | 73.3 | 86.7 | 80.0 |
AUC = area under the receiver operating characteristics curve, PPV = positive predicting value, NPV = negative predicting value.