Prediction of hip joint load and translation using musculoskeletal modelling with force-dependent kinematics and experimental validation.

Xuan Zhang1, Zhenxian Chen1, Ling Wang2, Wenjian Yang1, Dichen Li1, Zhongmin Jin3.   

Abstract

Musculoskeletal lower limb models are widely used to predict the resultant contact force in the hip joint as a non-invasive alternative to instrumented implants. Previous musculoskeletal models based on rigid body assumptions treated the hip joint as an ideal sphere with only three rotational degrees of freedom. An musculoskeletal model that considered force-dependent kinematics with three additional translational degrees of freedom was developed and validated in this study by comparing it with a previous experimental measurement. A 32-mm femoral head against a polyethylene cup was considered in the musculoskeletal model for calculating the contact forces. The changes in the main modelling parameters were found to have little influence on the hip joint forces (relative deviation of peak value < 10 BW%, mean trial deviation < 20 BW%). The centre of the hip joint translation was more sensitive to the changes in the main modelling parameters, especially muscle recruitment type (relative deviation of peak value < 20%, mean trial deviation < 0.02 mm). The predicted hip contact forces showed consistent profiles, compared with the experimental measurements, except in the lateral-medial direction. The ratio-average analysis, based on the Bland-Altman's plots, showed better limits of agreement in climbing stairs (mean limits of agreement: -2.0 to 6.3 in walking, mean limits of agreement: -0.5 to 3.1 in climbing stairs). Better agreement of the predicted hip contact forces was also found during the stance phase. The force-dependent kinematics approach underestimated the maximum hip contact force by a mean value of 6.68 ± 1.75% BW compared with the experimental measurements. The predicted maximum translations of the hip joint centres were 0.125 ± 0.03 mm in level walking and 0.123 ± 0.005 mm in climbing stairs. © IMechE 2015.

Entities:  

Keywords:  Musculoskeletal model; force-dependent kinematics; hip contact force; hip joint translation; muscle force

Mesh:

Year:  2015        PMID: 26063118     DOI: 10.1177/0954411915589115

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  6 in total

1.  The influence of spinal fusion length on proximal junction biomechanics: a parametric computational study.

Authors:  Dominika Ignasiak; Tobias Peteler; Tamás F Fekete; Daniel Haschtmann; Stephen J Ferguson
Journal:  Eur Spine J       Date:  2018-07-23       Impact factor: 3.134

2.  Biomechanical model based evaluation of Total Hip Arthroplasty therapy outcome.

Authors:  Jörg Eschweiler; Julia Hawlitzky; Valentin Quack; Markus Tingart; Björn Rath
Journal:  J Orthop       Date:  2017-09-21

3.  Femoral neck strain prediction during level walking using a combined musculoskeletal and finite element model approach.

Authors:  Zainab Altai; Erica Montefiori; Bart van Veen; Margaret A Paggiosi; Eugene V McCloskey; Marco Viceconti; Claudia Mazzà; Xinshan Li
Journal:  PLoS One       Date:  2021-02-01       Impact factor: 3.240

4.  Patient-specific musculoskeletal modeling of the hip joint for preoperative planning of total hip arthroplasty: A validation study based on in vivo measurements.

Authors:  Maximilian C M Fischer; Jörg Eschweiler; Fabian Schick; Malte Asseln; Philipp Damm; Klaus Radermacher
Journal:  PLoS One       Date:  2018-04-12       Impact factor: 3.240

5.  Refining muscle geometry and wrapping in the TLEM 2 model for improved hip contact force prediction.

Authors:  Enrico De Pieri; Morten E Lund; Anantharaman Gopalakrishnan; Kasper P Rasmussen; David E Lunn; Stephen J Ferguson
Journal:  PLoS One       Date:  2018-09-17       Impact factor: 3.240

6.  Reconstruction of the lower limb bones from digitised anatomical landmarks using statistical shape modelling.

Authors:  Daniel Nolte; Siu-Teing Ko; Anthony M J Bull; Angela E Kedgley
Journal:  Gait Posture       Date:  2020-02-15       Impact factor: 2.840

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.