Literature DB >> 26057215

Residual stress analysis of fixed retainer wires after in vitro loading: can mastication-induced stresses produce an unfavorable effect?

Iosif Sifakakis, Theodore Eliades, Christoph Bourauel.   

Abstract

The aim of the present study was to compare four different types of fixed canine-to-canine retainer regarding the maximum and residual force system generated on a canine during the intrusive in vitro loading of the rest of the anterior teeth. Retainers constructed from Ortho-FlexTech gold chain 0.038 × 0.016-inch (rectangular, 0.96 × 0.40 mm(²)), Tru-Chrome® 7-strand twisted 0.027-inch (round, 0.68 mm diameter) steel wire, and Wildcat 0.0175-inch (round, 0.44 mm) and 0.0215-inch (round, 0.55 mm) 3-strand Twistflex steel wire bonded on the anterior teeth of an acrylic resin model, installed in the Orthodontic Measurement and Simulation System. The force system on the canine was recorded during the loading of the anterior teeth as well as the residual force system at the same tooth after the unloading. During maximum loading, the gold chain exerted the lowest and the 0.0215-inch archwire the highest force and moment magnitude. Residual forces and moments were exerted on the canine after the unloading in all retainer types, i.e., the evaluated fixed retainers were not passive after in vitro vertical loading. The lowest magnitude was measured in gold chain retainers and the highest in cases of the high formable/low yield strength 0.027-inch archwire. This fact may explain the unexpected movements of teeth bonded on fixed retainers detected long-term in vivo.

Entities:  

Mesh:

Year:  2015        PMID: 26057215     DOI: 10.1515/bmt-2015-0013

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  4 in total

1.  Biomechanical properties of CAD/CAM-individualized nickel-titanium lingual retainers: an in vitro study.

Authors:  Stephan Christian Möhlhenrich; Fabian Jäger; Andreas Jäger; Pascal Schumacher; Michael Wolf; Ulrike Fritz; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2018-07-16       Impact factor: 1.938

2.  The efficacy of polyether-ether-ketone wire as a retainer following orthodontic treatment.

Authors:  Ammar Salim Kadhum; Akram Faisal Alhuwaizi
Journal:  Clin Exp Dent Res       Date:  2020-12-13

3.  3D-analysis of unwanted tooth movements despite bonded orthodontic retainers: a pilot study.

Authors:  Katharina Klaus; Faidra Xirouchaki; Sabine Ruf
Journal:  BMC Oral Health       Date:  2020-11-04       Impact factor: 2.757

4.  Orthodontic Retention-Protocols and Materials-A Questionnaire Pilot Study among Polish Practitioners.

Authors:  Maciej Jedliński; Marta Mazur; Krzysztof Schmeidl; Katarzyna Grocholewicz; Roman Ardan; Joanna Janiszewska-Olszowska
Journal:  Materials (Basel)       Date:  2022-01-16       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.